2,180 research outputs found

    Saliency Benchmarking Made Easy: Separating Models, Maps and Metrics

    Full text link
    Dozens of new models on fixation prediction are published every year and compared on open benchmarks such as MIT300 and LSUN. However, progress in the field can be difficult to judge because models are compared using a variety of inconsistent metrics. Here we show that no single saliency map can perform well under all metrics. Instead, we propose a principled approach to solve the benchmarking problem by separating the notions of saliency models, maps and metrics. Inspired by Bayesian decision theory, we define a saliency model to be a probabilistic model of fixation density prediction and a saliency map to be a metric-specific prediction derived from the model density which maximizes the expected performance on that metric given the model density. We derive these optimal saliency maps for the most commonly used saliency metrics (AUC, sAUC, NSS, CC, SIM, KL-Div) and show that they can be computed analytically or approximated with high precision. We show that this leads to consistent rankings in all metrics and avoids the penalties of using one saliency map for all metrics. Our method allows researchers to have their model compete on many different metrics with state-of-the-art in those metrics: "good" models will perform well in all metrics.Comment: published at ECCV 201

    The what and where of adding channel noise to the Hodgkin-Huxley equations

    Get PDF
    One of the most celebrated successes in computational biology is the Hodgkin-Huxley framework for modeling electrically active cells. This framework, expressed through a set of differential equations, synthesizes the impact of ionic currents on a cell's voltage -- and the highly nonlinear impact of that voltage back on the currents themselves -- into the rapid push and pull of the action potential. Latter studies confirmed that these cellular dynamics are orchestrated by individual ion channels, whose conformational changes regulate the conductance of each ionic current. Thus, kinetic equations familiar from physical chemistry are the natural setting for describing conductances; for small-to-moderate numbers of channels, these will predict fluctuations in conductances and stochasticity in the resulting action potentials. At first glance, the kinetic equations provide a far more complex (and higher-dimensional) description than the original Hodgkin-Huxley equations. This has prompted more than a decade of efforts to capture channel fluctuations with noise terms added to the Hodgkin-Huxley equations. Many of these approaches, while intuitively appealing, produce quantitative errors when compared to kinetic equations; others, as only very recently demonstrated, are both accurate and relatively simple. We review what works, what doesn't, and why, seeking to build a bridge to well-established results for the deterministic Hodgkin-Huxley equations. As such, we hope that this review will speed emerging studies of how channel noise modulates electrophysiological dynamics and function. We supply user-friendly Matlab simulation code of these stochastic versions of the Hodgkin-Huxley equations on the ModelDB website (accession number 138950) and http://www.amath.washington.edu/~etsb/tutorials.html.Comment: 14 pages, 3 figures, review articl

    A novel isolator-based system promotes viability of human embryos during laboratory processing

    Get PDF
    In vitro fertilisation (IVF) and related technologies are arguably the most challenging of all cell culture applications. The starting material is a single cell from which one aims to produce an embryo capable of establishing a pregnancy eventually leading to a live birth. Laboratory processing during IVF treatment requires open manipulations of gametes and embryos, which typically involves exposure to ambient conditions. To reduce the risk of cellular stress, we have developed a totally enclosed system of interlinked isolator-based workstations designed to maintain oocytes and embryos in a physiological environment throughout the IVF process. Comparison of clinical and laboratory data before and after the introduction of the new system revealed that significantly more embryos developed to the blastocyst stage in the enclosed isolator-based system compared with conventional open-fronted laminar flow hoods. Moreover, blastocysts produced in the isolator-based system contained significantly more cells and their development was accelerated. Consistent with this, the introduction of the enclosed system was accompanied by a significant increase in the clinical pregnancy rate and in the proportion of embryos implanting following transfer to the uterus. The data indicate that protection from ambient conditions promotes improved development of human embryos. Importantly, we found that it was entirely feasible to conduct all IVF-related procedures in the isolator-based workstations

    Simple, Fast and Accurate Implementation of the Diffusion Approximation Algorithm for Stochastic Ion Channels with Multiple States

    Get PDF
    The phenomena that emerge from the interaction of the stochastic opening and closing of ion channels (channel noise) with the non-linear neural dynamics are essential to our understanding of the operation of the nervous system. The effects that channel noise can have on neural dynamics are generally studied using numerical simulations of stochastic models. Algorithms based on discrete Markov Chains (MC) seem to be the most reliable and trustworthy, but even optimized algorithms come with a non-negligible computational cost. Diffusion Approximation (DA) methods use Stochastic Differential Equations (SDE) to approximate the behavior of a number of MCs, considerably speeding up simulation times. However, model comparisons have suggested that DA methods did not lead to the same results as in MC modeling in terms of channel noise statistics and effects on excitability. Recently, it was shown that the difference arose because MCs were modeled with coupled activation subunits, while the DA was modeled using uncoupled activation subunits. Implementations of DA with coupled subunits, in the context of a specific kinetic scheme, yielded similar results to MC. However, it remained unclear how to generalize these implementations to different kinetic schemes, or whether they were faster than MC algorithms. Additionally, a steady state approximation was used for the stochastic terms, which, as we show here, can introduce significant inaccuracies. We derived the SDE explicitly for any given ion channel kinetic scheme. The resulting generic equations were surprisingly simple and interpretable - allowing an easy and efficient DA implementation. The algorithm was tested in a voltage clamp simulation and in two different current clamp simulations, yielding the same results as MC modeling. Also, the simulation efficiency of this DA method demonstrated considerable superiority over MC methods.Comment: 32 text pages, 10 figures, 1 supplementary text + figur

    Object Detection Through Exploration With A Foveated Visual Field

    Get PDF
    We present a foveated object detector (FOD) as a biologically-inspired alternative to the sliding window (SW) approach which is the dominant method of search in computer vision object detection. Similar to the human visual system, the FOD has higher resolution at the fovea and lower resolution at the visual periphery. Consequently, more computational resources are allocated at the fovea and relatively fewer at the periphery. The FOD processes the entire scene, uses retino-specific object detection classifiers to guide eye movements, aligns its fovea with regions of interest in the input image and integrates observations across multiple fixations. Our approach combines modern object detectors from computer vision with a recent model of peripheral pooling regions found at the V1 layer of the human visual system. We assessed various eye movement strategies on the PASCAL VOC 2007 dataset and show that the FOD performs on par with the SW detector while bringing significant computational cost savings.Comment: An extended version of this manuscript was published in PLOS Computational Biology (October 2017) at https://doi.org/10.1371/journal.pcbi.100574

    Bioassay studies support the potential for latrogenic transmission of variant Creutzfeldt Jakob disease through dental procedures

    Get PDF
    Background: Evidence is required to quantify the potential risks of transmission of variant Creutzfeldt Jakob (vCJD) through dental procedures. Studies, using animal models relevant to vCJD, were performed to address two questions. Firstly, whether oral tissues could become infectious following dietary exposure to BSE? Secondly, would a vCJD-contaminated dental instrument be able to transmit disease to another patient? Methods: BSE-301V was used as a clinically relevant model for vCJD. VM-mice were challenged by injection of infected brain homogenate into the small intestine (Q1) or by five minute contact between a deliberately-contaminated dental file and the gingival margin (Q2). Ten tissues were collected from groups of challenged mice at three or four weekly intervals, respectively. Each tissue was pooled, homogenised and bioassayed in indicator mice. Findings: Challenge via the small intestine gave a transmission rate of 100% (mean incubation 157±17 days). Infectivity was found in both dental pulp and the gingival margin within 3 weeks of challenge and was observed in all tissues tested within the oral cavity before the appearance of clinical symptoms. Following exposure to deliberately contaminated dental files, 97% of mice developed clinical disease (mean incubation 234±33 days). Interpretation: Infectivity was higher than expected, in a wider range of oral tissues, than was allowed for in previous risk assessments. Disease was transmitted following transient exposure of the gingiva to a contaminated dental file. These observations provide evidence that dental procedures could be a route of cross-infection for vCJD and support the enforcement of single-use for certain dental instruments

    The impact of quality and accessibility of primary care on emergency admissions for a range of chronic ambulatory care sensitive conditions (ACSCs) in Scotland:longitudinal analysis

    Get PDF
    Funding This research was funded by the Chief Scientist Office (grant CZH/4/916). Health Economics Research Unit is funded by the Chief Scientist Office of the Scottish Government Health Directorate. AL is funded by the Medical Research Council (MC_UU_12017/13) and the Chief Scientist Office of the Scottish Government Health Directorate (SPHSU13)Peer reviewedPublisher PD

    Mapping the disease-specific LupusQoL to the SF-6D

    Get PDF
    Purpose To derive a mapping algorithm to predict SF-6D utility scores from the non-preference-based LupusQoL and test the performance of the developed algorithm on a separate independent validation data set. Method LupusQoL and SF-6D data were collected from 320 patients with systemic lupus erythematosus (SLE) attending routine rheumatology outpatient appointments at seven centres in the UK. Ordinary least squares (OLS) regression was used to estimate models of increasing complexity in order to predict individuals’ SF-6D utility scores from their responses to the LupusQoL questionnaire. Model performance was judged on predictive ability through the size and pattern of prediction errors generated. The performance of the selected model was externally validated on an independent data set containing 113 female SLE patients who had again completed both the LupusQoL and SF-36 questionnaires. Results Four of the eight LupusQoL domains (physical health, pain, emotional health, and fatigue) were selected as dependent variables in the final model. Overall model fit was good, with R2 0.7219, MAE 0.0557, and RMSE 0.0706 when applied to the estimation data set, and R2 0.7431, MAE 0.0528, and RMSE 0.0663 when applied to the validation sample. Conclusion This study provides a method by which health state utility values can be estimated from patient responses to the non-preference-based LupusQoL, generalisable beyond the data set upon which it was estimated. Despite concerns over the use of OLS to develop mapping algorithms, we find this method to be suitable in this case due to the normality of the SF-6D data

    Ears of the Armadillo: Global Health Research and Neglected Diseases in Texas

    Get PDF
    Neglected tropical diseases (NTDs) have\ud been recently identified as significant public\ud health problems in Texas and elsewhere in\ud the American South. A one-day forum on the\ud landscape of research and development and\ud the hidden burden of NTDs in Texas\ud explored the next steps to coordinate advocacy,\ud public health, and research into a\ud cogent health policy framework for the\ud American NTDs. It also highlighted how\ud U.S.-funded global health research can serve\ud to combat these health disparities in the\ud United States, in addition to benefiting\ud communities abroad

    Access and utilisation of maternity care for disabled women who experience domestic abuse:a systematic review

    Get PDF
    BACKGROUND: Although disabled women are significantly more likely to experience domestic abuse during pregnancy than non-disabled women, very little is known about how maternity care access and utilisation is affected by the co-existence of disability and domestic abuse. This systematic review of the literature explored how domestic abuse impacts upon disabled women’s access to maternity services. METHODS: Eleven articles were identified through a search of six electronic databases and data were analysed to identify: the factors that facilitate or compromise access to care; the consequences of inadequate care for pregnant women’s health and wellbeing; and the effectiveness of existing strategies for improvement. RESULTS: Findings indicate that a mental health diagnosis, poor relationships with health professionals and environmental barriers can compromise women’s utilisation of maternity services. Domestic abuse can both compromise, and catalyse, access to services and social support is a positive factor when accessing care. Delayed and inadequate care has adverse effects on women’s physical and psychological health, however further research is required to fully explore the nature and extent of these consequences. Only one study identified strategies currently being used to improve access to services for disabled women experiencing abuse. CONCLUSIONS: Based upon the barriers and facilitators identified within the review, we suggest that future strategies for improvement should focus on: understanding women’s reasons for accessing care; fostering positive relationships; being women-centred; promoting environmental accessibility; and improving the strength of the evidence base
    corecore