21 research outputs found
Nurses\u27 Alumnae Association Bulletin, May 1963
President\u27s Letter
Alumnae Meetings, 1962
Building Fund
Mediocrity
Hospital Report
Alumnae Notes
Social Committee
Student Activities
Marriages, New Arrivals and Necrology
Annual Giving Fund Driv
Nurses\u27 Alumnae Association Bulletin, June 1964
President\u27s Message
Officers and Committee Chairmen
Financial Report
Hospital and School of Nursing Report
Student Activities
Jefferson Expansion Program
Resume of Alumnae Meetings
Staff Nurses
Private Duty
Social Committee Reports
Program
Scholarship
Bulletin Committee Report
Annual Luncheon Notes
Membership and Dues
Units in Jefferson Expansion Program Center
Annual Giving Drive 1963
Report of Ways and Means Committee
Jefferson Building Fund Contributions
Annual Giving Contributions 1964
Jefferson Building Fund Report
Help the Building Fund Committee!
Vital Statistics
Class News
Notice
Great Yorkshire Livestock Show Attendees’ Attitudes about Agriculture
The purpose of our research was to determine if attending a U.K. livestock show changed attendees’ attitudes about agriculture and to compare those changes in attitudes to attendees of a U.S. state fair similar in size and dynamic. The sample was livestock show attendees at the Great Yorkshire Show (GYS). The mixed-method design included a then and now semantic differential scale with bipolar adjective pairs to measure attendees’ attitudes about agriculture before and after the experience and qualitative interviews with photo elicitation to learn about how attendees developed attitudes about agriculture. Participants had positive attitudes about agriculture before they attended the Show and had more positive attitudes after attending. Participants had more positive attitudes before and after attending the Show than did California State Fair attendees. In addition, participants lacked prior experiences with agriculture, but attending the GYS provided them the opportunity to develop positive attitudes through cognitive, behavioral, and environmental factors. Fair attendance should be promoted because they provide unique opportunities for experiential learning and U.S. fairs should adopt experiential tactics used at the GYS. Further research is needed to better understand how GYS attendees developed positive attitudes about agriculture prior to attending the Show and what elements of the GYS experience were most influential to attendees’ attitude development
Recommended from our members
The Active Personnel Dosimeter: Apfel Enterprises superheated drop detector
The Active Personnel Dosimeter (APD) provides a digital readout of events caused by neutrons interacting with superheated liquid droplets. The droplets are suspended in a gel held in a replaceable cartridge. Upon neutron interaction, the superheated droplet vaporizes, forming a bubble. The sound produced in this process is recorded by transducers that sense the accompanying pressure pulse. The APD electronically discriminates against spurious noise and vibration. Studies with the production prototype APDs indicate that the detector response is linear up to about 0.40 mSv, with large variations sometimes from predicted values and between cartridges at higher dose equivalents. The response to standard neutron sources (bare {sup 252}Cf, PuBe, PuB, PuF, PuLi) is reported and compared with the expected response. Unirradiated cartridges self-nucleate when heated to temperatures of 46{degree}C. The APD is insensitive to low-energy photons but responds to high-energy photons and electrons. 9 refs., 2 figs., 3 tabs
Recommended from our members
Factors affecting the response of the bubble detector BD-100 and a comparison of its response to CR-39
The BD-100 is a bubble detector available commercially from Chalk River Nuclear Laboratories, Canada for neutron dosimetry. According to the manufacturer, the BD-100 detects neutrons over an energy range of 100 keV to 14 MeV and the dose equivalent response is independent of energy. The sensitivity of the detector is dependent upon its temperature at the time of irradiation. The sensitized detector self-nucleates upon sharp impact and when heated to temperatures of 48/sup 0/C or greater. The BD-100 is insensitive to low energy gamma rays but responds to 6 MeV photons. The sensitivity (bubbles/..mu..Sv) of the BD-100 was found to be energy dependent when exposed to standard neutron sources with average energies ranging from 0.5 to 4.5 MeV. The bubbles formed upon irradiation continued to grow in size with time. The response of electrochemically etched CR-39 to the same neutron sources is also reported for comparison
w THE ACTIVE PERSONNEL DOSIMETER- APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*
Abstract- The Active Personnel Dosimeter (APD) provides a digital readout of events caused by-neutrons interacting with superheated liquid droplets. The droplets are suspended in a gel held in a replaceable cartridge. Upon neutron interaction, the superheated droplet vaporises, forming a bubble. The sound produced in this process is recorded by transducers that sense the accompanying pressure pulse. The APD electronically discriminates against spurious noise and vibration. Studies with the production prototype APDs indicate that the detector response is linear up to about 0.40 mSv, with large variations sometimes from predicted values and between cartridges at higher dose equivalents. The response to standard neutron sources (bare 252Cf, PuBe, PUB, PuF, PuLi) is reported and compared with the expected response. Unirradiated cartridges self-nucleate when heated to temperatures of 46OC. The APD is insensitive to low-energy photons but responds to high-energy photons and electrons
