590 research outputs found
Laser-driven X-ray and neutron source development for industrial applications of plasma accelerators
Pulsed beams of energetic X-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and X-ray beam generation. Measurements and Monte-Carlo radiation transport simulations show that neutron yield is increased by a factor ~ 2 when a 1mm copper foil is placed behind a 2mm lithium foil, compared to using a 2cm block of lithium only. We explore X-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent Bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte-Carlo code. We also demonstrate the unique capability of laser-driven X-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10ps drive pulse is presented for the first time, demonstrating that features of 200µm size are resolved when projected at high magnification
A Prospective Study of the Association of Metacognitive Beliefs and Processes with Persistent Emotional Distress After Diagnosis of Cancer
Two hundred and six patients, diagnosed with primary breast or prostate cancer completed self-report questionnaires on two occasions: before treatment (T1) and 12 months later (T2). The questionnaires included: the Hospital Anxiety and Depression Scale; Impact of Events Scale; the Metacognitions Questionnaire-30 (MCQ-30) and the Illness Perceptions Questionnaire-revised. A series of regression analyses indicated that metacognitive beliefs at T1 predicted between 14 and 19 % of the variance in symptoms of anxiety, depression and trauma at T2 after controlling for age and gender. For all three outcomes, the MCQ-30 subscale ‘negative beliefs about worry’ made the largest individual contribution with ‘cognitive confidence’ also contributing in each case. For anxiety, a third metacognitive variable, ‘positive beliefs about worry’ also predicted variance in T2 symptoms. In addition, hierarchical analyses indicated that metacognitive beliefs explained a small but significant amount of variance in T2 anxiety (2 %) and T2 depression (4 %) over and above that explained by demographic variables, T1 symptoms and T1 illness perceptions. The findings suggest that modifying metacognitive beliefs and processes has the potential to alleviate distress associated with cancer
Development of a fluorine-18 radiolabelled fluorescent chalcone: evaluated for detecting glycogen"
Background: Glycogen is a multibranched polysaccharide of glucose produced by cells to store energy and plays a key role in cancer. A previously reported fluorescent probe (CDg4) was shown to selectively bind glycogen in mouse embryonic stem cells, however the molecule was not evaluated in cancer cells. We report the synthesis and biological evaluation of a dual-modality imaging probe based on CDg4, for positron emission tomography (PET) and fluorescence microscopy. Results: A fluorine-18 radiolabelled derivative of CDg4, ([18F]5) for in vivo quantification of total glycogen levels in cancer cells was developed and synthesised in 170 min with a non-decay corrected radiochemical yield (RCY n.d.c) of 5.1 ± 0.9 % (n = 4) in >98% radiochemical purity. Compound 5 and [18F]5 were evaluated in vitro for their potential to bind glycogen, but only 5 showed accumulation by fluorescence microscopy. The accumulation of 5 was determined to be specific as fluorescent signal diminished upon the digestion of carbohydrate polymers with α-amylase. PET imaging in non-tumour bearing mice highlighted rapid hepato-biliary-intestinal elimination of [18F]5 and almost complete metabolic degradation after 60 min in the liver, plasma and urine, confirmed by radioactive metabolite analysis. Conclusions: Fluorescent compound 5 selectively accumulated in glycogen containing cancer cells, identified by fluorescence microscopy; however, rapid in vivo metabolic degradation precludes further investigation of [18F]5 as a PET radiopharmaceutical
Neural markers of negative symptom outcomes in distributed working memory brain activity of antipsychotic-naive schizophrenia patients
Weight Loss and Mortality in Overweight and Obese Cancer Survivors: A Systematic Review
Background Excess adiposity is a risk factor for poorer cancer survival, but there is uncertainty over whether losing weight reduces the risk. We conducted a critical review of the literature examining weight loss and mortality in overweight or obese cancer survivors. Methods We systematically searched PubMed and EMBASE for articles reporting associations between weight loss and mortality (cancer-specific or all-cause) in overweight/obese patients with obesity-related cancers. Where available, data from the same studies on non-overweight patients were compared. Results Five articles describing observational studies in breast cancer survivors were included. Four studies reported a positive association between weight loss and mortality in overweight/obese survivors, and the remaining study observed no significant association. Results were similar for non-overweight survivors. Quality assessment indicated high risk of bias across studies. Conclusions There is currently a lack of observational evidence that weight loss improves survival for overweight and obese cancer survivors. However, the potential for bias in these studies is considerable and the results likely reflect the consequences of disease-related rather than intentional weight loss. There is a need for stronger study designs, incorporating measures of intentionality of weight loss, and extended to other cancers
A general [F-18]AlF radiochemistry procedure on two automated synthesis platforms
The first general [18F]AIF automated radiolabelling procedure developed on the GE Tracerlab FX FN (Left) and Trasis AllInOne (Right) platforms.</p
A review of the distribution of particulate trace elements in urban terrestrial environments and its application to considerations of risk
We review the evolution, state of the art and future lines of research on the sources, transport pathways, and sinks of particulate trace elements in urban terrestrial environments to include the atmosphere, soils, and street and indoor dusts. Such studies reveal reductions in the emissions of some elements of historical concern such as Pb, with interest consequently focusing on other toxic trace elements such as As, Cd, Hg, Zn, and Cu. While establishment of levels of these elements is important in assessing the potential impacts of human society on the urban environment, it is also necessary to apply this knowledge in conjunction with information on the toxicity of those trace elements and the degree of exposure of human receptors to an assessment of whether such contamination represents a real risk to the city’s inhabitants and therefore how this risk can be addressed
- …
