454 research outputs found
Probing photo-ionization: simulations of positive streamers in varying N2:O2 mixtures
Photo-ionization is the accepted mechanism for the propagation of positive
streamers in air though the parameters are not very well known; the efficiency
of this mechanism largely depends on the presence of both nitrogen and oxygen.
But experiments show that streamer propagation is amazingly robust against
changes of the gas composition; even for pure nitrogen with impurity levels
below 1 ppm streamers propagate essentially with the same velocity as in air,
but their minimal diameter is smaller, and they branch more frequently.
Additionally, they move more in a zigzag fashion and sometimes exhibit a
feathery structure. In our simulations, we test the relative importance of
photo-ionization and of the background ionization from pulsed repetitive
discharges, in air as well as in nitrogen with 1 ppm O2 . We also test
reasonable parameter changes of the photo-ionization model. We find that photo-
ionization dominates streamer propagation in air for repetition frequencies of
at least 1 kHz, while in nitrogen with 1 ppm O2 the effect of the repetition
frequency has to be included above 1 Hz. Finally, we explain the feather-like
structures around streamer channels that are observed in experiments in
nitrogen with high purity, but not in air.Comment: 12 figure
Investigation of the relevant kinetic processes in the initial stage of a double-arcing instability in oxygen plasmas
A numerical investigation of the kinetic processes in the initial (nanosecond range) stage of the double-arcing instability was developed. The plasma-sheath boundary region of an oxygen-operated cutting torch was considered. The energy balance and chemistry processes in the discharge were described. It is shown that the double-arcing instability is a sudden transition from a diffuse (glow-like) discharge to a constricted (arc-like) discharge in the plasma-sheath boundary region arising from a field-emission instability. A critical electric field value of ∼10^7 V/m was found at the cathodic part of the nozzle wall under the conditions considered. The field-emission instability drives in turn a fast electronic-to-translational energy relaxation mechanism, giving rise to a very fast gas heating rate of at least ∼10^9 K/s, mainly due to reactions of preliminary dissociation of oxygen molecules via the highly excited electronic state O2(B^3) populated by electron impact. It is expected that this fast oxygen heating rate further stimulates the discharge contraction through the thermal instability mechanism.Fil: Mancinelli, Beatriz Rosa. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto; ArgentinaFil: Prevosto, Leandro. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: Chamorro Garcés, Juan Camilo. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto; ArgentinaFil: Minotti, Fernando Oscar. Universidad de Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Kelly, Hector Juan. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentin
From cold to fusion plasmas: spectroscopy, molecular dynamics and kinetic considerations
Calculated rates for the electron impact dissociation of molecular hydrogen: mixed isotopomers and scaling laws
Current practice and surgical outcomes of neoadjuvant chemotherapy for early breast cancer : UK NeST study
Funding Information: This work was funded by a grant from the Association of Breast SurgeryPeer reviewedPublisher PD
Identification and immunophenotype of abnormal cells present in focal cortical dysplasia type IIb
Effects of primordial chemistry on the cosmic microwave background
Previous works have demonstrated that the generation of secondary CMB
anisotropies due to the molecular optical depth is likely too small to be
observed. In this paper, we examine additional ways in which primordial
chemistry and the dark ages might influence the CMB. We present a detailed and
updated chemical network and give an overview of the interactions of molecules
with the CMB. We consider the optical depth due to line absorption,
photoionization, photodissociation and free-free processes, and estimate the
resulting changes in the CMB temperature and its power spectrum. The most
promising results are obtained for the negative hydrogen ion \HM and the \HeHII
molecule. The free-free process of \HM yields a relative change in the CMB
temperature of up to , and leads to a frequency-dependent
change in the power spectrum of the order at 30 GHz. With a change of
the order in the power spectrum, our result for the bound-free
process of \HM is significantly below a previous suggestion. \HeHII efficiently
scatters CMB photons and smears out primordial fluctuations, leading to a
change in the power spectrum of the order . Improvements in the
accuracy of future CMB experiments may thus help to constrain and finally
detect these interesting signals from the dark ages of the universe.Comment: 16 pages, 15 figures, accepted for publication at A&A. Discussion
section update
Organization and Activity of Italian Echocardiographic Laboratories: A Survey of the Italian Society of Echocardiography and Cardiovascular Imaging
Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography
Stress echocardiography in Italian echocardiographic laboratories: A survey of the Italian society of echocardiography and cardiovascular imaging
Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and >= 40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers
- …
