11,545 research outputs found

    Complete gradient-LC-ESI system on a chip for protein analysis

    Get PDF
    This paper presents the first fully integrated gradient-elution liquid chromatography-electrospray ionization (LC-ESI) system on a chip. This chip integrates a pair of high-pressure gradient pumps, a sample injection pump, a passive mixer, a packed separation column, and an ESI nozzle. We also present the successful on-chip separation of protein digests by reverse phase (RP)-LC coupled with on-line mass spectrometer (MS) analysis

    Electrolysis-based diaphragm actuators

    Get PDF
    This work presents a new electrolysis-based microelectromechanical systems (MEMS) diaphragm actuator. Electrolysis is a technique for converting electrical energy to pneumatic energy. Theoretically electrolysis can achieve a strain of 136 000% and is capable of generating a pressure above 200 MPa. Electrolysis actuators require modest electrical power and produce minimal heat. Due to the large volume expansion obtained via electrolysis, small actuators can create a large force. Up to 100 µm of movement was achieved by a 3 mm diaphragm. The actuator operates at room temperature and has a latching and reversing capability

    Impact-picture predictions for the γγ\gamma\gamma total cross section at LEP

    Full text link
    We show that the rising total cross section σ(γγhadrons)\sigma(\gamma\gamma \to hadrons) recently observed by the L3 and OPAL Collaborations at LEP are fully consistent with the impact-picture for high-energy scattering. The impact picture is then used to predict this total cross section at higher energies. These experimental results confirm once more the success of the theoretical approach, which predicted for the first time, nearly thirty years ago, the universal increase of total cross sections at high energies.Comment: 5 pages, Latex, 1 figure. Revised versio

    Supersymmetric Mean-Field Theory of t-J Model

    Full text link
    The supersymmetric formulation of t-J model is studied in this paper at the mean-field level where δ\delta-T phase diagram is computed. We find that slave-fermion-like spiral phase is stable at low doping concentration, and the slave-boson-like d-wave fermionic spin pairing state becomes energetically favourable when δ\delta\geq 0.23. An improvement in free energy using Gutzwiller's method lowers the transition doping concentration to 0.06. We also point out the existence of new branches of excitations in the supersymmetric theory.Comment: 11 pages and 2 figure

    Phase diagram of doped BaFe2_2As2_2 superconductor under broken C4C_4 symmetry

    Full text link
    We develop a minimal multiorbital tight-binding model with realistic hopping parameters. The model breaks the symmetry of the tetragonal point group by lowering it from C4C_4 to D2dD_{2d}, which accurately describes the Fermi surface evolution of the electron-doped BaFe2x_{2-x}Cox_xAs2_2 and hole-doped Ba1y_{1-y}Ky_yFe2_2As2_2 compounds. An investigation of the phase diagram with a mean-field tt-UU-VV Bogoliubov-de Gennes Hamiltonian results in agreement with the experimentally observed electron- and hole-doped phase diagram with only one set of tt, UU and VV parameters. Additionally, the self-consistently calculated superconducting order parameter exhibits s±s^\pm-wave pairing symmetry with a small d-wave pairing admixture in the entire doping range, % The superconducting s±+ds^\pm + d-wave order parameter which is the subtle result of the weakly broken symmetry and competing interactions in the multiorbital mean-field Hamiltonian

    A suspended microchannel with integrated temperature sensors for high-pressure flow studies

    Get PDF
    A freestanding microchannel, with integrated temperature sensors, has been developed for high-pressure flow studies. These microchannels are approximately 20μm x 2μm x 4400μm, and are suspended above 80 μm deep cavities, bulk micromachined using BrF3 dry etch. The calibration of the lightly boron-doped thermistor-type sensors shows that the resistance sensitivity of these integrated sensors is parabolic with respect to temperature and linear with respect to pressure. Volumetric flow rates of N2 in the microchannel were measured at inlet pressures up to 578 psig. The discrepancy between the data and theory results from the flow acceleration in a channel, the non-parabolic velocity profile, and the bulging of the channel. Bulging effects were evaluated by using incompressible water flow measurements, which also measures 1.045x10^-3N-s/m^2 for the viscosity of DI water. The temperature data from sensors on the channel shows the heating of the channel due to the friction generated by the high-pressure flow inside

    Micro heat exchanger by using MEMS impinging jets

    Get PDF
    A micro impinging-jet heat exchanger is presented here. Heat transfer is studied for single jet, slot arrays and jet arrays. In order to facilitate micro heat transfer measurements with these devices, a MEMS sensor chip, which has an 8 x 8 temperature-sensor array on one side, and an integrated heater on the other side has been designed and fabricated. This sensor chip allows 2-D surface temperature measurement with various jets impinging on it. It is found that micro impinging jets can be highly efficient when compared to existing macro impinging-jet microelectronics packages such as IBM 4381. For example, using a single nozzle jet (500-μm diameter driven by 5 psig pressure), the sensor chip (2 x 2 cm^2) temperature can be cooled down from 70 to 33°C. The cooling becomes more efficient when nozzle arrays (4x5 over 1 cm^2 area) are used under the same driving pressure. Interestingly, although higher driving pressure gives better cooling (lower surface temperature), the cooling efficiency, defined as h/0.5pv^2, is actually higher for lower driving pressure
    corecore