16,352 research outputs found

    Away-side azimuthal distribution in a Markovian parton scattering model

    Full text link
    An event generator is constructed on the basis of a model of multiple scattering of partons so that the trajectory of a parton traversing a dense and expanding medium can be tracked. The parameters in the code are adjusted to fit the \Delta\phi azimuthal distribution on the far side when the trigger momentum is in the non-perturbative region, p_T(trigger)<4 GeV/c. The dip-bump structure for 1<p_T(assoc)<2.5 GeV/c is reproduced by averaging over the exit tracks of deflected jets. An essential characteristic of the model, called Markovian Parton Scattering (MPS) model, is that the scattering angle is randomly selected in the forward cone at every step of a trajectory that is divided into many discrete steps in a semi-classical approximation of the non-perturbative scattering process. Energy loss to the medium is converted to thermal partons which hadronize by recombination to give rise to the pedestal under the bumps. When extended to high trigger momentum with \pt(trigger) >8 GeV/c, the model reproduces the single-peak structure observed by STAR without invoking any new dynamical mechanism.Comment: 20 pages + 3 figure

    Speed of light as measured by two terrestrial stable clocks

    Get PDF
    Despite the recent criticism within the special theory of relativity, there exists an arrangement of stable clocks rotating with the earth which predicts diurnal variations of the one-way speed of light, as suggested previously

    A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

    Get PDF
    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15)×104  cm1ppm1(1.51\pm 0.15)\times10^{-4} \;\mathrm{cm^{-1} ppm^{-1}}, corresponding to an absorption cross section of (7.14±0.74)×1021  cm2molecule1(7.14 \pm 0.74)\times10^{-21}\;\mathrm{cm^{2} molecule^{-1}}. We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±330 \pm 3 meters.Comment: v2: Correct mistake in molecular absorption cross section calculation, and a minor typo in fig

    Influence of retardation effects on 2D magnetoplasmon spectrum

    Full text link
    Within dissipationless limit the magnetic field dependence of magnetoplasmon spectrum for unbounded 2DEG system found to intersect the cyclotron resonance line, and, then approaches the frequency given by light dispersion relation. Recent experiments done for macroscopic disc-shape 2DEG systems confirm theory expectations.Comment: 2 pages,2 figure
    corecore