33 research outputs found
Comparison of different methods for delayed post-mortem diagnosis of falciparum malaria
<p>Abstract</p> <p>Background</p> <p>Between 10,000 and 12,000 cases of imported malaria are notified in the European Union each year. Despite an excellent health care system, fatalities do occur. In case of advanced autolysis, the post-mortem diagnostic is impaired. Quicker diagnosis could be achieved by using rapid diagnostic malaria tests.</p> <p>Methods</p> <p>In order to evaluate different methods for the post-mortem diagnosis of <it>Plasmodium falciparum </it>malaria in non-immunes, a study was performed on the basis of forensic autopsies of corpses examined at variable intervals after death in five cases of fatal malaria (with an interval of four hours to five days), and in 20 cases of deaths unrelated to malaria. Detection of parasite DNA by PCR and an immunochromatographic test (ICT) based upon the detection of <it>P. falciparum </it>histidine-rich protein 2 (PfHRP2) were compared with the results of microscopic examination of smears from cadaveric blood, histopathological findings, and autopsy results.</p> <p>Results</p> <p>In all cases of fatal malaria, post-mortem findings were unsuspicious for the final diagnosis, and autoptic investigations, including histopathology, were only performed because of additional information by police officers and neighbours. Macroscopic findings during autopsy were unspecific. Histopathology confirmed sequestration of erythrocytes and pigment in macrophages in most organs in four patients (not evaluable in one patient due to autolysis). Microscopy of cadaveric blood smears revealed remnants of intraerythrocytic parasites, and was compromised or impossible due to autolysis in two cases. PCR and ICT performed with cadaveric blood were positive in all malaria patients and negative in all controls.</p> <p>Conclusion</p> <p>In non-immune fatalities with unclear anamnesis, ICT can be recommended as a sensitive and specific tool for post-mortem malaria diagnosis, which is easier and faster than microscopy, and also applicable when microscopic examination is impossible due to autolysis. PCR is more expensive and time-consuming, but may be used as confirmatory test. In highly endemic areas where asymptomatic parasitaemia is common, confirmation of the diagnosis of malaria as the cause of death has to rely on histopathological findings.</p
Parasitological correlates of Plasmodium ovale curtisi and Plasmodium ovale wallikeri infection
Molecular characterization of misidentified Plasmodium ovale imported cases in Singapore
A French soldier returns from the Central Africa Republic with hepatitis A: Vaccination failure is possible!
An analysis of the benefit of using HEV genotype 3 antigens in detecting anti-HEV IgG in a European population.
BACKGROUND: The benefit of using serological assays based on HEV genotype 3 in industrialised settings is unclear. We compared the performance of serological kits based on antigens from different HEV genotypes.
METHODS: Taking 20 serum samples from patients in southwest France with acute HEV infection (positive PCR for HEV genotype 3) and 550 anonymised samples from blood donors in southwest Switzerland, we tested for anti-HEV IgG using three enzyme immunoassays (EIAs) (MP Diagnostics, Dia.Pro and Fortress) based on genotype 1 and 2 antigens, and one immunodot assay (Mikrogen Diagnostik recomLine HEV IgG/IgM) based on genotype 1 and 3 antigens.
RESULTS: All acute HEV samples and 124/550 blood donor samples were positive with ≥1 assay. Of PCR-confirmed patient samples, 45%, 65%, 95% and 55% were positive with MP Diagnostics, Dia.Pro, Fortress and recomLine, respectively. Of blood donor samples positive with ≥1 assay, 120/124 (97%), were positive with Fortress, 19/124 (15%) were positive with all EIAs and 51/124 (41%) were positive with recomLine. Of 11/20 patient samples positive with recomLine, stronger reactivity for HEV genotype 3 was observed in 1/11(9%), and equal reactivity for both genotypes in 5/11 (45.5%).
CONCLUSIONS: Although recomLine contains HEV genotype 3, it has lower sensitivity than Fortress in acute HEV infection and fails to identify infection as being due to this genotype in approximately 45% of patients. In our single blood donor population, we observe wide variations in measured seroprevalence, from 4.2% to 21.8%, depending on the assay used
