5,146 research outputs found
Endoscopic scores for inflammatory bowel disease in the era of 'mucosal healing'. old problem, new perspectives
The importance of the endoscopic evaluation in inflammatory bowel disease (IBD) management has been recognized for many years. However, the modalities for reporting endoscopic activity represent an ongoing challenge. To address this, several endoscopic scores have been proposed. Very few have been properly validated, and the use of such tools remains sub-optimal and is mainly restricted to clinical trials. In recent years, a growing emphasis of the concept of 'mucosal healing' as a prognostic marker and therapeutic goal has increased the need for a more accurate definition of endoscopic activity in both ulcerative colitis (UC) and Crohn's Disease (CD). In the present review, the evolution of the challenges related to endoscopic scores in IBD has been analyzed, with particular attention paid to the renewed relevance of endoscopic activity in recent years. Currently, despite the growing relevance of endoscopic activity, evaluating this activity in IBD is still a challenge. The implementation of efficacious endoscopic scores and a better definition of the absence of activity (mucosal healing) are needed.The importance of the endoscopic evaluation in inflammatory bowel disease (IBD) management has been recognized for many years. However, the modalities for reporting endoscopic activity represent an ongoing challenge. To address this, several endoscopic scores have been proposed. Very few have been properly validated, and the use of such tools remains sub-optimal and is mainly restricted to clinical trials. In recent years, a growing emphasis of the concept of 'mucosal healing' as a prognostic marker and therapeutic goal has increased the need for a more accurate definition of endoscopic activity in both ulcerative colitis (UC) and Crohn's Disease (CD). In the present review, the evolution of the challenges related to endoscopic scores in IBD has been analyzed, with particular attention paid to the renewed relevance of endoscopic activity in recent years. Currently, despite the growing relevance of endoscopic activity, evaluating this activity in IBD is still a challenge. The implementation of efficacious endoscopic scores and a better definition of the absence of activity (mucosal healing) are needed
Performance of the diamond active target prototype for the PADME experiment at the DANE BTF
The PADME experiment at the DANE Beam-Test Facility (BTF) is designed
to search for the gauge boson of a new interaction in the process
ee+, using the intense positron beam hitting a
light target. The , usually referred as dark photon, is assumed to
decay into invisible particles of a secluded sector and it can be observed by
searching for an anomalous peak in the spectrum of the missing mass measured in
events with a single photon in the final state. The measurement requires the
determination of the 4-momentum of the recoil photon, performed by a
homogeneous, highly segmented BGO crystals calorimeter. A significant
improvement of the missing mass resolution is possible using an active target
capable to determine the average position of the positron bunch with a
resolution of less than 1 mm. This report presents the performance of a real
size PADME active target made of a thin (50 m) diamond
sensor, with graphitic strips produced via laser irradiation on both sides. The
measurements are based on data collected in a beam test at the BTF in November
2015.Comment: 7 pages, 10 figure
Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in
Italy, will search for invisible decays of the hypothetical dark photon via the
process , where the escapes detection. The
dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We
report here on measurement and simulation studies of the performance of the
Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting
2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of
less than 200 ps, which is satisfied by the choice of PbF crystals and the
newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a
timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns)
and a single-crystal energy resolution of 5.7%/ with light yield of
2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test
Facility of LNF. We also propose the investigation of a two-PMT solution
coupled to a single PbF crystal for higher-energy applications, which has
potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie
Skin to skin interactions. Does the infant massage improve the couple functioning?
Transition to parenthood is a critical stage of life due to several changes the couple has to handle. A large body of studies described how transition to parenthood can be linked to the onset of depressive symptoms, as well as the perception of a low social support, and an increased stress, representing a risk for the early mother—baby relationship. Infant Massage (IM) emerged as an helpful tool to improve maternal skills in interacting with the baby, and leading toward a decreasing of post partum symptoms. However, a growing body of literature highlights that men also may experience post-partum diseases, representing an additional risk for the development of the baby. To date, no study observed the impact of the infant massage on both partners. The aim of the current qualitative research is to observe the impact of the IM on a single couple of parents at childbirth. Pre (Time 1) and post-intervention (Time 3) procedure has been established to observe the changes occurring over the time in the couple. In particular, each member of the couple filled out the EPDS, the BDI-II, the MSPSS and the PSI-SF both at Time 1 and at Time 3. The treatment (Time 2) was represented by the IM training, and lasted 4 weeks. Findings revealed a decrease in depressive symptoms in both partners, as well as an improvement of their perception of stress related to parental role. No changes has been detected with respect to the perception of social support. The IM seems to be a helpful approach to prevent the establishment of pathological conditions in new parents. Although no direct measures on the child were used, the current qualitative data seem to suggest that the IM may represent a valuable tool to prevent the onset of early negative outcomes of the baby. Further investigations and empirical data are needed to improve the knowledge in this field
Cosmic ray spectrum and composition with the Pierre Auger Observatory
The Pierre Auger Observatory investigates the origin and nature of Ultra High Energy Cosmic Rays (UHECRs) using a hybrid detector. An introduction to the hybrid detector and a review of selected results are presented with an emphasis on the measurement of the cosmic ray energy spectrum and mass composition
Performance of the PADME calorimeter prototype at the DANE BTF
The PADME experiment at the DANE Beam-Test Facility (BTF) aims at
searching for invisible decays of the dark photon by measuring the final state
missing mass in the process , with undetected. The
measurement requires the determination of the 4-momentum of the recoil photon,
performed using a homogeneous, highly segmented BGO crystals calorimeter. We
report the results of the test of a 55 crystals prototype performed
with an electron beam at the BTF in July 2016
Public Entities Officers and Employees / Expedited Judicial Review Ensures that Restraints on the Adult Entertainment Industry Pass Constitutional Muster
The Central Laser Facility at the Pierre Auger Observatory
The Central Laser Facility is located near the middle of the Pierre Auger
Observatory in Argentina. It features a UV laser and optics that direct a beam
of calibrated pulsed light into the sky. Light scattered from this beam
produces tracks in the Auger optical detectors which normally record nitrogen
fluorescence tracks from cosmic ray air showers. The Central Laser Facility
provides a "test beam" to investigate properties of the atmosphere and the
fluorescence detectors. The laser can send light via optical fiber
simultaneously to the nearest surface detector tank for hybrid timing analyses.
We describe the facility and show some examples of its many uses.Comment: 4 pages, 5 figures, submitted to 29th ICRC Pune Indi
- …
