92 research outputs found

    Fourier transform for quantum DD-modules via the punctured torus mapping class group

    Get PDF
    We construct a certain cross product of two copies of the braided dual H~\tilde H of a quasitriangular Hopf algebra HH, which we call the elliptic double EHE_H, and which we use to construct representations of the punctured elliptic braid group extending the well-known representations of the planar braid group attached to HH. We show that the elliptic double is the universal source of such representations. We recover the representations of the punctured torus braid group obtained in arXiv:0805.2766, and hence construct a homomorphism to the Heisenberg double DHD_H, which is an isomorphism if HH is factorizable. The universal property of EHE_H endows it with an action by algebra automorphisms of the mapping class group SL2(Z)~\widetilde{SL_2(\mathbb{Z})} of the punctured torus. One such automorphism we call the quantum Fourier transform; we show that when H=Uq(g)H=U_q(\mathfrak{g}), the quantum Fourier transform degenerates to the classical Fourier transform on D(g)D(\mathfrak{g}) as q1q\to 1.Comment: 12 pages, 1 figure. Final version, to appear in Quantum Topolog

    The international normalized ratio overestimates coagulopathy in patients after major hepatectomy

    Get PDF
    Abstract BACKGROUND: The International Normalized Ratio (INR) is commonly used to guide therapy after hepatectomy. We hypothesized that the use of thrombelastography (TEG) would demonstrate a decreased incidence of hypocoagulability in this patient population. METHODS: Seventy-eight patients were prospectively enrolled before undergoing hepatectomy. INR, TEG, and coagulation factors were drawn before incision, postoperatively, and on postoperative days 1, 3, and 5. RESULTS: Patients demonstrated an elevated INR at all postoperative time points. However, TEG demonstrated a decreased R value postoperatively, with subsequent normalization. Other TEG measurements were equivalent to preoperative values. All procoagulant factors save factor VIII decreased postoperatively, with a simultaneous decrease in protein C. CONCLUSIONS: TEG demonstrated a brief hypercoagulable state after major hepatectomy, with coagulation subsequently normalizing. The INR significantly overestimates hypocoagulability after hepatectomy and these data call into question current practices using the INR to guide therapy in this patient population. Ó 2014 Elsevier Inc. All rights reserved. Partial hepatectomy remains the treatment of choice for a wide range of both benign and malignant diseases of the liver. Following major hepatectomy, derangement of hepatic synthetic function has been well characterized, including impaired synthesis of serum clotting factors and regulatory proteins

    Reuse of measurement plans based on process and quality models

    No full text
    Measurement is needed for project control, quality assurance, and process improvement activities in software development. Measurement planning is a difficult and time-consuming activity. Therefore, a great interest exists in reusing measurement plans. However, most measurement plans are structured intuitively and are written informally. Therefore, they are difficult to understand and to reuse. The contents of measurement plans strongly depend on the object being measured and the quality focus of measurement. Process models (describing the object) and quality models (describing the quality focus) change from project to project and over time. Therefore, in order to reuse measurement plans from one project to the next, relationships between measurement plans and process and quality models are needed. These relationships can be used to identify and adapt existing measurement plans to varying process and quality models. This paper presents a formal conceptual model of measurement plans including relationships to process and quality models and a development process for such measurement plans. This model and process build a sound basis for reuse of measurement plans. To further support reuse, a conceptual model for components of measurement plan elements is sketched. Components can be reused to build new measurement plans. A rudimentary reuse process is proposed that starts from a similarity analysis of the (reused and new) underlying process model and quality models

    Kontinuierliche Software-Qualitätsverbesserung in der industriellen Praxis

    Get PDF
    In der industriellen Praxis werden immer häufiger Verbesserungs- und Meßansätze zur Steigerung der Qualität von Software-Produkten und -Projektdurchführungen diskutiert. Dieser Artikel gibt eine Übersicht über potentielle Ansätze zur kontinuierliche Software-Qualitätsverbesserung: QIP, CMM und AMI. Aus dem Vergleich der Verbesserungsansätze geht hervor, daß u.a. zielorientiertes Messen eine integrale Technologie zur Verbesserung ist. Deshalb wird in diesem Artikel ein Ansatz für zielorientiertes Messen, der GQM-Ansatz, detaillierter diskutiert. Insbesondere wird auf die Anwendung in der Praxis eingegangen, wobei die Erfahrungen aus realen Projekten in Form von Richtlinien vorgestellt werden. Der Artikel will Praktikern einen Einstieg in die Software Qualitätsverbesserung mittels Messen vermittlen

    A Flexible Control Center Architecture for Support of Diverse Spaceflight Missions

    Full text link
    corecore