40 research outputs found
Management of pleural effusion secondary to malignant mesothelioma
Malignant pleural mesothelioma (MPM) is a highly aggressive pleural tumour which has been epidemiologically linked to occupational exposure to asbestos. MPM is often associated with pleural effusion, which is a common cause of morbidity and whose management remains a clinical challenge. In this review, we analysed the literature regarding the diagnosis and therapeutic options of pleural effusion secondary to mesothelioma. Our aim was to provide a comprehensive view on this subject, and a new algorithm was proposed as a practical aid to clinicians dealing with patients suffering from pleural effusion
Implementation of a new robotic surgical system for general thoracic surgery, early experience
the versius surgical system is a commercially available european robotic platform that representan alternative to the well-structured US robotic system. The aim of this study is to describe the clinical implementation of the versius in a tertiary university hospital following the ideal development framework for surgical innovatio
Triportal anatomical pulmonary resection with a new robotic platform: early experience
The purpose of this study is to compare the first experiences in typical lung resections carried out with the robotic versius surgical system versus the thoracoscopic procedur
Pulmonary metastasectomy : an overview
Metastasectomy is the most frequent surgical resection undertaken by thoracic surgeons, being the lung the second common site of metastases. The present oncological criteria for pulmonary metastasectomy are: (I) the primary cancer need to be controlled or controllable; (II) no extrathoracic metastasis-that is not controlled or controllable-exists; (III) all of the tumor must be resectable, with adequate pulmonary reserve; (IV) there are no alternative medical treatment options with lower morbidity. General favourable prognostic features in patients with pulmonary metastases are: (I) one or few metastases; (II) long disease free interval; (III) normal CEA levels in colorectal cancers. Negative predictive features in patients candidate to pulmonary metastasectomies are: (I) active primary cancer; (II) extrathoracic metastases; (III) inability to obtain surgical radicality; (IV) mediastinal lymphatic spread. The lack of controlled trials and studies limited by short follow-up and small cohorts did not allow to overcome some skepticism; moreover, the heterogeneity of these patients in terms of demographic, biologic and histologic characteristics represents a clear limit even in the largest series. On the basis of present knowledge, without results coming from on-going randomized trials, radical resection, histology, and disease free interval seem to be independent prognostic factors identifying a cohort of patients maximally benefitting from lung metastasectomy
Lung Transplantation and Extracorporeal Photopheresis as Induction Therapy in Cystic Fibrosis Patients: Immune System Profile Changes
Acute rejection (AR), common during the first year after lung
transplantation (LuTx), can trigger chronic rejection (CR), the leading
cause of late morbidity and mortality of LuTx. Extracorporeal photopheresis
(ECP) has emerged as a promising treatment for chronic rejection.
Only few studies are focus on ECP as prophylactic therapy of AR and CR.
This study aims to verify, in recipients affected by cystic fibrosis (CF),
whether the induction therapy with ECP can decrease the rate of AR, in
order to impact positively on CR (primary end point: survival, AR). The
expected results are the reduction of AR episodes in its clinical and histopathological
manifestation
Diagnostic performance and cell count of EBUS–TBNA needle gauges: a prospective trial
Background. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a well-established diagnostic procedure for evaluating hilar and mediastinal lymphadenopathies and is the gold standard for lung cancer diagnosis and staging. Recent studies assessed the effectiveness of the 19-G flex needle in obtaining larger EBUS-TBNA samples, and prospective small series gave similar results in terms of diagnostic yield when testing different gauge needles. The lack of homogeneity between series and the small sample size of some prospective cohorts poses a limit to the validity of those results. This prospective controlled study compared the 19-G flex and 22-G needles in terms of diagnostic yield. An objective laboratory method was used to count cells and compare the two needles’ cytologic yields. Material. A prospective controlled study was conducted on 90 patients undergoing EBUS-TBNA for the diagnosis of hilar and mediastinal lymphadenopathies. The institutional ethic committee (IEO573) approved the study, and informed consent was obtained from all patients. Results. A total of 90 patients were enrolled in this study, 84.4% of whom were diagnosed with malignancy and 15.6% with non-neoplastic disease. Sensitivity for malignancy was 93.4% (CI: 87.4–97.1%) for the 19-G needle and 92.6% (CI: 86.3–96.5%) for the 22-G needle (p = 0.80). The percentage of malignant cells in the cell block was 63.9% and 61.5% for the 22-G and 19-G needles, respectively. The cell count assessed by flow cytometry was 2071 cells/μL (IQR: 600,2265) with the 22-G needle and 2761 cells/μL (IQR: 505,3250) with the 19-G needle (p = 0.79). The malignant cell count was 0.05 × 103 cells/μL with the 22-G and 0.08 × 103 cells/μL with the 19-G needle (p = 0.70). There was no difference in the presence of tissue cores in the samples, and rapid on-site evaluation (ROSE) cellularity was comparable between the two needles. Conclusions. The 19-G flex EBUS-TBNA needle is comparable to the 22-G needle in terms of diagnostic yield for cyto-histological evaluation of hilar and mediastinal lymphadenopathies. There is no difference between the 19-G and 22-G needle cell counts evaluated by flow cytometry
A new tetraoxa-tetraaza macrobicyclic anthracenyl luminescent receptor: control of the receptor-substrate stoichiometry
The luminescent receptor 1 incorporating anthracenyl groups as luminophores and a tetraoxa-tetraaza macrobicyclic receptor as the binding subunit has been synthesized and its interactions with Ca-II, investigated by fluorescence measurements, are reported. The receptor-substrate 1-Ca system is an example of multistability at the molecular level, triggered by a reversible modification of the receptor ability and evidenced by luminescence
Endobronchial Ultrasound Transbronchial Needle Aspiration In Thoracic Diseases: Much More Than Mediastinal Staging
Background and Objective. EBUS-TBNA has revolutionized the diagnostic approach to thoracic diseases from a surgical to minimally invasive procedure. In non small-cell lung cancer (NCSLC) patients, EBUS-TBNA is able to dictate the consecutive therapy both for early and advanced stages, providing pathological diagnosis, mediastinal staging, and even adequate specimens for molecular analysis. This study reports on the ability of EBUS-TBNA to make different diagnoses and dictates the consecutive therapy in a large cohort of patients presenting different thoracic diseases. Methods. All procedures performed from January 2012 to September 2016 were reviewed. Five groups of patients were created according to the main indications for the procedure. Group 1: lung cancer staging; Group 2: pathological diagnosis in advanced stage lung cancer; Group 3: lymphadenopathy in previous malignancies; Group 4: pulmonary lesions; Group 5: unknown origin lymphadenopathy. In each group, the diagnostic yield of the procedure was analysed. Non malignant diagnosis at EBUS-TBNA was confirmed by a surgical procedure or clinical and radiological follow-up. Results. 1891 patients were included in the analysis. Sensitivity, negative predictive value, and diagnostic accuracy in each group were 90.7%, 79.4%, and 93.1% in Group 1; 98.5%, 50%, and 98.5% in Group 2; 92.4%, 85.1%, and 94.7% in Group 3; 90.9%, 51.0%, and 91.7% in Group 4; and 25%, 83.3%, and 84.2% in Group 5. Overall sensitivity, negative predictive value, and accuracy were 91.7%, 78.5%, and 93.6%, respectively. Conclusions. EBUS-TBNA is the best approach for invasive mediastinal investigation, confirming its strategic role and high accuracy in thoracic oncology
EBUS-TBNA in PET-positive lymphadenopathies in treated cancer patients
Mediastinal lymph node enlargement is common in the follow-up of patients with previously treated malignancies. The aim of this study is to assess the role of endobronchial ultrasound (EBUS) transbronchial needle aspiration (TBNA) for cyto-histological evaluation of positron emission tomography with 18fluorodeoxyglucose (PET) positive mediastinal and hilar lymph nodes developed in patients with previous malignancies. All EBUS-TBNA cases performed from January 2012 to May 2016 were retrospective reviewed. Results of EBUS-TBNA in patients with mediastinal and/or hilar lymphadenopathies were analysed. Non-malignant cytopathologies were confirmed with surgical procedures or clinical and radiological follow-up. Among 1780 patients, 176 were included in the analysis. 103 of these (58.5%) had a diagnosis of tumour recurrence whereas 73 (41.5%) had a different diagnosis: 63 (35.8%) had a non-neoplastic diagnosis and 8 patients (4.6%) had a different cell type malignancy. Samples were false-negative in 5 (2.8%) out of 176 patients. The overall sensitivity, specificity, negative predicted value and diagnostic accuracy were 95.7% (95% CI 90.2-98.6%), 100% (95% CI 94.0-100%), 92.3% (95% CI 83.2-96.7%) and 97.2% (95% CI 93.5-98.8%), respectively. EBUS-TBNA demonstrated a pathological diagnosis different from the previous tumour in a large percentage of patients, confirming its strategic role in the management of patients with previously treated malignancies
