1,348 research outputs found
Orientation filtering by growth-velocity competition in zone-melting recrystallization of silicon on SiO_2
We describe a method of controlling the in-plane directions of grains in (100)-textured silicon films produced by zone-melting recrystallization over amorphous SiO2. Grains having in-plane orientation within a narrow range are able to grow through an orientation filter consisting of a pattern of crystallization barriers, while grains having other orientations are occluded. The results of experiments using an orientation filter, and the parameters which optimize filter performance, are reported
The 158 micron (CII) mapping of galaxies: Probing the atomic medium
Using the MPE/UCB Far-infrared Imaging Fabry-Perot Interferometer (FIFI) on the Kuiper Airborne Observatory (KAO), we have made large scale maps of (CII) in the spiral galaxies NGC 6946, NGC 891, M83 and the peculiar elliptical Cen A, thus allowing for the first time, detailed studies of the spatial distribution of the FIR line emission in external galaxies. We find that the (CII) emission comes from a mixture of components of interstellar gas. The brightest emission is associated with the nuclear regions, a second component traces the spiral arms as seen in the nearly face on spiral galaxies NGC 6946 and M83 and the largest star forming/H2 regions contained within them, and another extended component of low brightness can be detected in all of the galaxies far from the nucleus, beyond the extent of CO emission
Correction of coagulation in the hemophilic dog by transplantation of lymphatic tissue
Available data concerning the non-hepatic source of plasma factor VIII are conflicting. In the present study, dogs with factor VIII deficiency hemophilia were transplanted with spleen or vascularized lymph node grafts obtained from normal donor dogs. Postoperative immunosuppression was done with azathioprine and heterologous antilymphocyte globulin. Four spleen transplants were successful and the recipients had positive technetium sulfide spleen scans along with adequate plasma factor VIII levels for three to eight weeks. Cessation of graft isotope uptake was accompanied by prompt disappearance of plasma factor in all four dogs. Histologically, the grafts were rejected at this time. In one dog, a second spleen graft immediately restored therapeutic factor VIII levels. Four lymph node transplants were successful and plasma factor VIII was detected for one, one, two, and ten weeks. Three dogs rejected their lymph node grafts with disappearance of factor VIII, while one had a viable transplant removed with loss of factor VIII within two days. The data suggest that factor VIII is produced in the lymphatic tissue of the dog. © 1974
Star Formation in M51 Triggered by Galaxy Interaction
We have mapped the inner 360'' regions of M51 in the 158micron [CII] line at
55'' spatial resolution using the Far-infrared Imaging Fabry-Perot
Interferometer (FIFI) on the Kuiper Airborne Observatory (KAO). The emission is
peaked at the nucleus, but is detectable over the entire region mapped, which
covers much of the optical disk of the galaxy. There are also two strong
secondary peaks at ~43% to 70% of the nuclear value located roughly 120'' to
the north-east, and south-west of the nucleus. These secondary peaks are at the
same distance from the nucleus as the corotation radius of the density wave
pattern. The density wave also terminates at this location, and the outlying
spiral structure is attributed to material clumping due to the interaction
between M51 and NGC5195. This orbit crowding results in cloud-cloud collisions,
stimulating star formation, that we see as enhanced [CII] line emission. The
[CII] emission at the peaks originates mainly from photodissociation regions
(PDRs) formed on the surfaces of molecular clouds that are exposed to OB
starlight, so that these [CII] peaks trace star formation peaks in M51. The
total mass of [CII] emitting photodissociated gas is ~2.6x10^{8} M_{sun}, or
about 2% of the molecular gas as estimated from its CO(1-0) line emission. At
the peak [CII] positions, the PDR gas mass to total gas mass fraction is
somewhat higher, 3-17%, and at the secondary peaks the mass fraction of the
[CII] emitting photodissociated gas can be as high as 72% of the molecular
mass.... (continued)Comment: 14 pages, 6 figures, Accepted in ApJ (for higher resolution figures
contact the author
The effects of star formation on the low-metallicity ISM: NGC4214 mapped with Herschel/PACS spectroscopy
We present Herschel/PACS spectroscopic maps of the dwarf galaxy NC4214
observed in 6 far infrared fine-structure lines: [C II] 158mu, [O III] 88mu, [O
I] 63mu, [O I] 146mu, [N II] 122mu, and [N II] 205mu. The maps are sampled to
the full telescope spatial resolution and reveal unprecedented detail on ~ 150
pc size scales. We detect [C II] emission over the whole mapped area, [O III]
being the most luminous FIR line. The ratio of [O III]/[C II] peaks at about 2
toward the sites of massive star formation, higher than ratios seen in dusty
starburst galaxies. The [C II]/CO ratios are 20 000 to 70 000 toward the 2
massive clusters, which are at least an order of magnitude larger than spiral
or dusty starbursts, and cannot be reconciled with single-slab PDR models.
Toward the 2 massive star-forming regions, we find that L[CII] is 0.5 to 0.8%
of the LTIR . All of the lines together contribute up to 2% of LTIR . These
extreme findings are a consequence of the lower metallicity and young,
massive-star formation commonly found in dwarf galaxies. These conditions
promote large-scale photodissociation into the molecular reservoir, which is
evident in the FIR line ratios. This illustrates the necessity to move to
multiphase models applicable to star-forming clusters or galaxies as a whole.Comment: Accepted for publication in the A&A Herschel Special Issu
Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-timeof- flight MS comparing organic and integrated pest management farming
This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 μg kg−1 for fluazifop-pbutyl
to 50 μg kg−1 for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits
Measurement of the proton electric to magnetic form factor ratio from \vec ^1H(\vec e, e'p)
We report the first precision measurement of the proton electric to magnetic
form factor ratio from spin-dependent elastic scattering of longitudinally
polarized electrons from a polarized hydrogen internal gas target. The
measurement was performed at the MIT-Bates South Hall Ring over a range of
four-momentum transfer squared from 0.15 to 0.65 (GeV/c).
Significantly improved results on the proton electric and magnetic form factors
are obtained in combination with previous cross-section data on elastic
electron-proton scattering in the same region.Comment: 4 pages, 2 figures, submitted to PR
Implementing electronic data capture at a well-established health and demographic surveillance site in rural northern Malawi.
This article aims to assess multiple issues of resources, staffing, local opinion, data quality, cost, and security while transitioning to electronic data collection (EDC) at a long-running community research site in northern Malawi. Levels of missing and error fields, delay from data collection to availability, and average number of interviews per day were compared between EDC and paper in a complex, repeated annual household survey. Three focus groups with field and data staff with experience using both methods, and in-depth interviews with participants were carried out. Cost for each method were estimated and compared. Missing data was more common on paper questionnaires than on EDC, and a similar number were carried out per day. Fieldworkers generally preferred EDC, but data staff feared for their employment. Most respondents had no strong preference for a method. The cost of the paper system was estimated to be higher than using EDC. The existing infrastructure and technical expertise could be adapted to using EDC, but changes have an impact on data processing jobs as fewer, and better qualified staff are required. EDC is cost-effective, and, for a long-running site, may offer further savings, as devices can be used in multiple studies and perform several other functions. EDC is accepted by fieldworkers and respondents, has good levels of quality and timeliness, and security can be maintained. EDC is well-suited for use in a well-established research site using and developing existing infrastructure and expertise
Removing krypton from xenon by cryogenic distillation to the ppq level
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the -emitter
Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10 mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.410 with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions
- …
