2,823 research outputs found

    Requirements for high-efficiency solar cells

    Get PDF
    Minimum recombination and low injection level are essential for high efficiency. Twenty percent AM1 efficiency requires a dark recombination current density of 2 x 10 to the minus 13th power A/sq cm and a recombination center density of less than 10 to the 10th power /cu cm. Recombination mechanisms at thirteen locations in a conventional single crystalline silicon cell design are reviewed. Three additional recombination locations are described at grain boundaries in polycrystalline cells. Material perfection and fabrication process optimization requirements for high efficiency are outlined. Innovative device designs to reduce recombination in the bulk and interfaces of single crystalline cells and in the grain boundary of polycrystalline cells are reviewed

    Recombination phenomena in high efficiency silicon solar cells

    Get PDF
    The dominant recombination phenomena which limit the highest efficiency attainable in silicon solar cells under terrestrial sunlight are reviewed. The ultimate achievable efficiency is limited by the two intrinsic recombination mechanisms, the interband Auger recombination and interband Radiative recombination, both of which occur in the entire cell body but principally in the base layer. It is suggested that an optimum (26%) cell design is one with lowly doped 50 to 100 micron thick base, a perfect BSF, and zero extrinsic recombination such as the thermal mechanism at recombination centers the Shockley-Read-Hall process (SRH) in the bulk, on the surface and at the interfaces. The importance of recombination at the interfaces of a high-efficiency cell is demonstrated by the ohmic contact on the back surface whose interface recombination velocity is infinite. The importance of surface and interface recombination is demonstrated by representing the auger and radiative recombination losses by effective recombination velocities. It is demonstrated that the three highest efficiency cells may all be limited by the SRH recombination losses at recombination centers in the base layer

    Loss mechanisms in high-efficiency solar cells: Study of material properties and high-efficiency solar-cell performance on material composition: Project tasks

    Get PDF
    Loss mechanisms in high-efficiency solar cells were discussed. Fundamental limitations and practical solutions were stressed. Present cell efficiency is limited by many recombination sites: emitter, base, contacts, and oxide/silicon interface. Use of polysilicon passivation was suggested. After reduction of these losses, a 25% efficient cell could be built. A floating emitter cell design was shown that had the potential of low recombination losses

    Study of relationships of material properties and high efficiency solar cell performance on material composition

    Get PDF
    The performance improvements obtainable from extending the traditionally thin back-surface-field (BSF) layer deep into the base of silicon solar cells under terrestrial solar illumination (AM1) are analyzed. This extended BSF cell is also known as the back-drift-field cell. About 100 silicon cells were analyzed, each with a different emitter or base dopant impurity distribution whose selection was based on physically anticipated improvements. The four principal performance parameters (the open-circuit voltage, the short-circuit current, the fill factor, and the maximum efficiency) are computed using a FORTRAN program, called Circuit Technique for Semiconductor-device Analysis, CTSA, which numerically solves the six Shockley Equations under AM1 solar illumination at 88.92 mW/cm, at an optimum cell thickness of 50 um. The results show that very significant performance improvements can be realized by extending the BSF layer thickness from 2 um (18% efficiency) to 40 um (20% efficiency)

    Experimental investigation of the excess charge and time constant of minority carriers in the thin diffused layer of 0.1 ohm-cm silicon solar cells

    Get PDF
    An experimental method is presented that can be used to interpret the relative roles of bandgap narrowing and recombination processes in the diffused layer. This method involves measuring the device time constant by open-circuit voltage decay and the base region diffusion length by X-ray excitation. A unique illuminated diode method is used to obtain the diode saturation current. These data are interpreted using a simple model to determine individually the minority carrier lifetime and the excess charge. These parameters are then used to infer the relative importance of bandgap narrowing and recombination processes in the diffused layer

    Hyaluronan concentration and size distribution in human knee synovial fluid: variations with age and cartilage degeneration.

    Get PDF
    BackgroundOne potential mechanism for early superficial cartilage wear in normal joints is alteration of the lubricant content and quality of synovial fluid. The purpose of this study was to determine if the concentration and quality of the lubricant, hyaluronan, in synovial fluid: (1) was similar in left and right knees; (2) exhibited similar age-associated trends, whether collected postmortem or antemortem; and (3) varied with age and grade of joint degeneration.MethodsHuman synovial fluid of donors (23-91 years) without osteoarthritis was analyzed for the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5-7 MDa, 1-2.5 MDa, 0.5-1 MDa, and 0.03-0.5 MDa. Similarity of data between left and right knees was assessed by reduced major axis regression, paired t-test, and Bland-Altman analysis. The effect of antemortem versus postmortem collection on biochemical properties was assessed for age-matched samples by unpaired t-test. The relationships between age, joint grade, and each biochemical component were assessed by regression analysis.ResultsJoint grade and the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5-7 MDa, 1-2.5 MDa, and 0.5-1 MDa in human synovial fluid showed good agreement between left and right knees and were similar between age-matched patient and cadaver knee joints. There was an age-associated decrease in overall joint grade (-15 %/decade) and concentrations of hyaluronan (-10.5 %/decade), and hyaluronan in the molecular weight ranges of 2.5-7 MDa (-9.4 %/decade), 1-2.5 MDa (-11.3 %/decade), 0.5-1 MDa (-12.5 %/decade), and 0.03-0.5 MDa (-13.0 %/decade). Hyaluronan concentration and quality was more strongly associated with age than with joint grade.ConclusionsThe age-related increase in cartilage wear in non-osteoarthritic joints may be related to the altered hyaluronan content and quality of synovial fluid

    WZW orientifolds and finite group cohomology

    Full text link
    The simplest orientifolds of the WZW models are obtained by gauging a Z_2 symmetry group generated by a combined involution of the target Lie group G and of the worldsheet. The action of the involution on the target is by a twisted inversion g \mapsto (\zeta g)^{-1}, where \zeta is an element of the center of G. It reverses the sign of the Kalb-Ramond torsion field H given by a bi-invariant closed 3-form on G. The action on the worldsheet reverses its orientation. An unambiguous definition of Feynman amplitudes of the orientifold theory requires a choice of a gerbe with curvature H on the target group G, together with a so-called Jandl structure introduced in hep-th/0512283. More generally, one may gauge orientifold symmetry groups \Gamma = Z_2 \ltimes Z that combine the Z_2-action described above with the target symmetry induced by a subgroup Z of the center of G. To define the orientifold theory in such a situation, one needs a gerbe on G with a Z-equivariant Jandl structure. We reduce the study of the existence of such structures and of their inequivalent choices to a problem in group-\Gamma cohomology that we solve for all simple simply-connected compact Lie groups G and all orientifold groups \Gamma = Z_2 \ltimes Z.Comment: 48+1 pages, 11 figure

    Lower Gastrointestinal Bleeding Due to Multiple Polyps in Ileum

    Full text link
    The causes of lower gastrointestinal bleeding (hematochezia) are amyloidosis, anal fissure, angiodysplastic lesions, coagulation disorder, colitis, colon cancer, colorectal polyps, Crohn's disease, diverticulitis, haemorrhoids, etc. This was a case of lower gastrointestinal bleeding due to colonic inflammatoric polyp. This inflammatoric polyps were caused by infection/inflammation and improved after antibiotic and NSAID therapy
    corecore