103 research outputs found

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    Get PDF
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns

    Josephson Junctions and AdS/CFT Networks

    Get PDF
    We propose a new holographic model of Josephson junctions (and networks thereof) based on designer multi-gravity, namely multi-(super)gravity theories on products of distinct asymptotically AdS spacetimes coupled by mixed boundary conditions. We present a simple model of a Josephson junction (JJ) that exhibits the well-known current-phase sine relation of JJs. In one-dimensional chains of holographic superconductors we find that the Cooper-pair condensates are described by a discretized Schrodinger-type equation. Such non-integrable equations, which have been studied extensively in the past in condensed matter and optics applications, are known to exhibit complex behavior that includes periodic and quasiperiodic solutions, chaotic dynamics, soliton and kink solutions. In our setup these solutions translate to holographic configurations of strongly-coupled superconductors in networks with weak site-to-site interactions that exhibit interesting patterns of modulated superconductivity. In a continuum limit our equations reduce to generalizations of the Gross-Pitaevskii equation. We comment on the many possible extensions and applications of this new approach.Comment: 39 pages, 11 figures; v2 clarified the nature and computation of the Josephson current in subsec. 3.2 and specific properties of the two-site system, analogous minor modifications in subsec. 4.4 and added a new subsec. 4.5 with a new fig.

    High-resolution DNA copy number and gene expression analyses distinguish chromophobe renal cell carcinomas and renal oncocytomas

    Get PDF
    Contains fulltext : 80487.pdf (publisher's version ) (Open Access)BACKGROUND: The diagnosis of benign renal oncocytomas (RO) and chromophobe renal cell carcinomas (RCC) based on their morphology remains uncertain in several cases. METHODS: We have applied Affymetrix GeneChip Mapping 250 K NspI high-density oligoarrays to identify small genomic alterations, which may occur beyond the specific losses of entire chromosomes, and also Affymetrix GeneChip HG-U133 Plus2.0 oligoarrays for gene expression profiling. RESULTS: By analysing of DNA extracted from 30 chRCCs and 42 ROs, we have confirmed the high specificity of monosomies of chromosomes 1, 2, 6, 10, 13, 17 and 21 in 70-93% of the chRCCs, while ROs displayed loss of chromosome 1 and 14 in 24% and 5% of the cases, respectively. We demonstrated that chromosomal gene expression biases might correlate with chromosomal abnormalities found in chromophobe RCCs and ROs. The vast majority genes downregulated in chromophobe RCC were mapped to chromosomes 2, 6, 10, 13 and 17. However, most of the genes overexpressed in chromophobe RCCs were located to chromosomes without any copy number changes indicating a transcriptional regulation as a main event. CONCLUSION: The SNP-array analysis failed to detect recurrent small deletions, which may mark loci of genes involved in the tumor development. However, we have identified loss of chromosome 2, 10, 13, 17 and 21 as discriminating alteration between chromophobe RCCs and ROs. Therefore, detection of these chromosomal changes can be used for the accurate diagnosis in routine histology

    Politicising government engagement with corporate social responsibility: “CSR” as an empty signifier

    Get PDF
    Governments are widely viewed by academics and practitioners (and society more generally) as the key societal actors who are capable of compelling businesses to practice corporate social responsibility (CSR). Arguably, such government involvement could be seen as a technocratic device for encouraging ethical business behaviour. In this paper, we offer a more politicised interpretation of government engagement with CSR where “CSR” is not a desired form of business conduct but an element of discourse that governments can deploy in structuring their relationships with other social actors. We build our argument through a historical analysis of government CSR discourse in the Russian Federation. Laclau and Mouffe's (Hegemony and socialist strategy: Towards a radical democratic politics,Verso Books, London, 1985) social theory of hegemony underpins our research. We find that “CSR” in the Russian government’s discourse served to legitimise its power over large businesses. Using this case, we contribute to wider academic debates by providing fresh empirical evidence that allows the development of critical evaluation tools in relation to governments’ engagement with “CSR”. We find that governments are capable of hijacking CSR for their own self-interested gain. We close the paper by reflecting on the merit of exploring the case of the Russian Federation. As a “non-core”, non-western exemplar, it provides a useful “mirror” with which to reflect on the more widely used test-bed of Western industrial democracies when scrutinising CSR. Based on our findings, we invite other scholars to adopt a more critical, politicised stance when researching the role of governments in relation to CSR in other parts of the world

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Performance of the CMS drift tube chambers with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the paper can be accessed from the link below - Copyright @ 2010 IOPStudies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    corecore