47 research outputs found
Retinal and choroidal thickness measurements using spectral domain optical coherence tomography in anterior and intermediate uveitis.
L
Recommended from our members
The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length
Purpose
The purpose of this study was to assess the effects of incorporating individual ocular biometry measures of corneal curvature, refractive error, and axial length on scan length obtained using Spectralis spectral domain optical coherence tomography (SD-OCT).
Methods
Two SD-OCT scans were acquired for 50 eyes of 50 healthy participants, first using the Spectralis default keratometry (K) setting followed by incorporating individual mean-K values. Resulting scan lengths were compared to predicted scan lengths produced by image simulation software, based on individual ocular biometry measures including axial length.
Results
Axial length varied from 21.41 to 29.04 mm. Spectralis SD-OCT scan lengths obtained with default-K ranged from 5.7 to 7.3 mm, and with mean-K from 5.6 to 7.6 mm. We report a stronger correlation of simulated scan lengths incorporating the subject’s mean-K value (ρ = 0.926, P < 0.0005) compared to Spectralis default settings (ρ = 0.663, P < 0.0005).
Conclusions
Ocular magnification appears to be better accounted for when individual mean-K values are incorporated into Spectralis SD-OCT scan acquisition versus using the device’s default-K setting. This must be considered when taking area measurements and lateral measurements parallel to the retinal surface
Spectral domain optical coherence tomography in patients after successful management of postoperative endophthalmitis following cataract surgery by pars plana vitrectomy.
BACKGROUND: Acute severe postoperative endophthalmitis may lead to severe vision loss. The aim of this study was the analysis of macular microstructure imaged by spectral domain optical coherence tomography in patients after pars plana vitrectomy due to postcataract endophthalmitis. METHODS: A cross sectional study was carried out in 17 patients who had cataract surgery in both eyes and underwent unilateral pars plana vitrectomy due to postcataract endophthalmitis. Postoperative best corrected visual acuity was determined in both eyes. Evaluation of macular thickness, macular volume, peripapillary retinal nerve fiber layer thickness and choroidal thickness using enhanced depth imaging technique was performed by spectral domain optical coherence tomography. The measurements obtained in the operated eye were compared to the fellow eye by Wilcoxon matched pair test. Correlation test was performed by Spearman rank order. RESULTS: A mean postoperative best corrected visual acuity of 63 +/- 30 ETDRS letters versus 75 +/- 21 letters was achieved in the study and fellow eyes, respectively, after a mean of 5.3 +/- 4.5 months (p = 0.1). The mean macular thickness was 320.6 +/- 28.8 mum SD in the study eyes compared to 318.4 +/- 18.8 mum in the fellow eyes (p = 0.767). No differences were noted in macular volume (p = 0.97) and in peripapillary retinal nerve fiber layer thickness (p = 0.31). Choroidal thickness was significantly lower in the study eyes compared to the fellow eyes (p = 0.018). Epiretinal membrane was found in 7 eyes after endophthalmitis, while in the fellow eyes only in 3 cases (p = 0.13, Fisher's exact test). CONCLUSION: Choroidal thickness decreased significantly after endophthalmitis, but there was no functional correlation with the changes in choroidal microstructure. The development of epiretinal membranes may be associated with either vitrectomy or endophthalmitis in the history. Absence of other significant structural and morphological findings shows that successful treatment may guarantee good clinical results even in long term after this severe postoperative complication
Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software
PURPOSE: To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software.
METHODS: High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman's ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit.
RESULTS: Inter-scan CoR values ranged from 3.1μm for axial retinal nerve fibre layer thickness to 15.0μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550μm ± 322μm with a CoR of 13μm for inter-investigator and 40μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P 0.05); however this symmetry could not be found at 5° eccentricity.
CONCLUSIONS: We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea
