445 research outputs found

    Information and the gaining of understanding

    Get PDF
    It is suggested that, in addition to data, information and knowledge, the information sciences should focus on understanding, understood as a higher-order knowledge, with coherent and explanatory potential. The limited ways in which understanding has been addressed in the design of information systems, in studies of information behaviour, in formulations of information literacy, and in impact studies are briefly reviewed, and future prospects considered. The paper is an extended version of a keynote presentation given at the i3 conference in June 2015

    Tracing the wider impacts of biomedical research: A literature search to develop a novel citation categorisation technique

    Get PDF
    There is an increasing need both to understand the translation of biomedical research into improved healthcare and to assess the range of wider impacts from health research such as improved health policies, health practices and healthcare. Conducting such assessments is complex and new methods are being sought. Our new approach involves several steps. First, we developed a qualitative citation analysis technique to apply to biomedical research in order to assess the contribution that individual papers made to further research. Second, using this method, we then proposed to trace the citations to the original research through a series of generations of citing papers. Third, we aimed eventually to assess the wider impacts of the various generations. This article describes our comprehensive literature search to inform the new technique. We searched various databases, specific bibliometrics journals and the bibliographies of key papers. After excluding irrelevant papers we reviewed those remaining for either general or specific details that could inform development of our new technique. Various characteristics of citations were identified that had been found to predict their importance to the citing paper including the citation’s location; number of citation occasions and whether the author(s) of the cited paper were named within the citing paper. We combined these objective characteristics with subjective approaches also identified from the literature search to develop a citation categorisation technique that would allow us to achieve the first of the steps above, i.e., being able routinely to assess the contribution that individual papers make to further research.Medical Research Council as part of the MRC-NIHR Methodology Research Programme, and Professor Martin Buxton

    SRAO CO Observation of 11 Supernova Remnants in l = 70 to 190 deg

    Full text link
    We present the results of 12CO J = 1-0 line observations of eleven Galactic supernova remnants (SNRs) obtained using the Seoul Radio Astronomy Observatory (SRAO) 6-m radio telescope. The observation was made as a part of the SRAO CO survey of SNRs between l = 70 and 190 deg, which is intended to identify SNRs interacting with molecular clouds. The mapping areas for the individual SNRs are determined to cover their full extent in the radio continuum. We used halfbeam grid spacing (60") for 9 SNRs and full-beam grid spacing (120") for the rest. We detected CO emission towards most of the remnants. In six SNRs, molecular clouds showed a good spatial relation with their radio morphology, although no direct evidence for the interaction was detected. Two SNRs are particularly interesting: G85.4+0.7, where there is a filamentary molecular cloud along the radio shell, and 3C434.1, where a large molecular cloud appears to block the western half of the remnant. We briefly summarize the results obtained for individual SNRs.Comment: Accepted for publication in Astrophysics & Space Science. 12 pages, 12 figures, and 3 table

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Mapping recent information behavior research: an analysis of co-authorship and cocitation networks

    Get PDF
    There has been an increase in research published on information behavior in recent years, and this has been accompanied by an increase in its diversity and interaction with other fields, particularly information retrieval (HR). The aims of this study are to determine which researchers have contributed to producing the current body of knowledge on this subject, and to describe its intellectual basis. A bibliometric and network analysis was applied to authorship and co-authorship as well as citation and co-citation. According to these analyses, there is a small number of authors who can be considered to be the most productive and who publish regularly, and a large number of transient ones. Other findings reveal a marked predominance of theoretical works, some examples of qualitative methodology that originate in other areas of social science, and a high incidence of research focused on the user interaction with information retrieval systems and the information behavior of doctors

    Wear and corrosion interactions on titanium in oral environment : literature review

    Get PDF
    The oral cavity is a complex environment where corrosive substances from dietary, human saliva, and oral biofilms may accumulate in retentive areas of dental implant systems and prostheses promoting corrosion at their surfaces. Additionally, during mastication, micromovements may occur between prosthetic joints causing a relative motion between contacting surfaces, leading to wear. Both processes (wear and corrosion) result in a bio-tribocorrosion system once that occurs in contact with biological tissues and fluids. This review paper is focused on the aspects related to the corrosion and wear behavior of titanium-based structures in the oral environment. Furthermore, the clinical relevance of the oral environment is focused on the harmful effect that acidic substances and biofilms, formed in human saliva, may have on titanium surfaces. In fact, a progressive degradation of titanium by wear and corrosion (tribocorrosion) mechanisms can take place affecting the performance of titanium-based implant and prostheses. Also, the formation of wear debris and metallic ions due to the tribocorrosion phenomena can become toxic for human tissues. This review gathers knowledge from areas like materials sciences, microbiology, and dentistry contributing to a better understanding of bio-tribocorrosion processes in the oral environment.(undefined

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    Get PDF
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns
    corecore