1,189 research outputs found

    Multi-resolution decomposition applied to crackle detection

    Get PDF
    Crackles, heard over the lungs in a variety of diseases, are one of the most important physical signs in clinical medicine. They have an explosive pattern in the time domain, with a rapid onset and short duration. The timing, repeatability and shape of crackles are important parameters for diagnosis. Therefore, automatic detection of crackles and their classification as fine and coarse crackles have important clinical value. Since the multi-resolution decomposition technique can give high resolution in both time and frequency, it can be exploited to detect crackles and to classify them according to the information in each scale. In this paper, we present a new method for crackle detection based on the continuous wavelet transform. The theory, methods and experimental results are given in detail in this paper.published_or_final_versio

    Crackle detection and classification based on matched waveletanalysis

    Get PDF
    Crackles have an explosive pattern in the time domain, with a rapid onset and a short duration. The timing, repeatability and shape of crackles are important parameters for diagnosis. Therefore, automatic detection of crackles and their classification have important clinical value. Since crackles have a general characteristic shape, it is obvious that wavelet analysis can be exploited to detect crackles and to classify them. In this paper, we present a new method for crackle detection which is based on a `matched' wavelet transform. We first model crackles as a mathematical function. Then we design a matched wavelet based on this model. Applying a soft threshold to the results of the continuous wavelet transform to suppress noise further, the optimal scale can be obtained. Crackles can be detected based on the envelope of the signal at an optimal scale, and can be classified based on the energy distribution with scale. Theory, methods and experimental results are given in detail in this paper.published_or_final_versio

    Smart homes and their users:a systematic analysis and key challenges

    Get PDF
    Published research on smart homes and their users is growing exponentially, yet a clear understanding of who these users are and how they might use smart home technologies is missing from a field being overwhelmingly pushed by technology developers. Through a systematic analysis of peer-reviewed literature on smart homes and their users, this paper takes stock of the dominant research themes and the linkages and disconnects between them. Key findings within each of nine themes are analysed, grouped into three: (1) views of the smart home-functional, instrumental, socio-technical; (2) users and the use of the smart home-prospective users, interactions and decisions, using technologies in the home; and (3) challenges for realising the smart home-hardware and software, design, domestication. These themes are integrated into an organising framework for future research that identifies the presence or absence of cross-cutting relationships between different understandings of smart homes and their users. The usefulness of the organising framework is illustrated in relation to two major concerns-privacy and control-that have been narrowly interpreted to date, precluding deeper insights and potential solutions. Future research on smart homes and their users can benefit by exploring and developing cross-cutting relationships between the research themes identified

    A Fibreoptic Endoscopic Study of Upper Gastrointestinal Bleeding at Bugando Medical Centre in Northwestern Tanzania: a Retrospective Review of 240 Cases.

    Get PDF
    Upper gastrointestinal (GI) bleeding is recognized as a common and potentially life-threatening abdominal emergency that needs a prompt assessment and aggressive emergency treatment. A retrospective study was undertaken at Bugando Medical Centre in northwestern Tanzania between March 2010 and September 2011 to describe our own experiences with fibreoptic upper GI endoscopy in the management of patients with upper gastrointestinal bleeding in our setting and compare our results with those from other centers in the world. A total of 240 patients representing 18.7% of all patients (i.e. 1292) who had fibreoptic upper GI endoscopy during the study period were studied. Males outnumbered female by a ratio of 2.1:1. Their median age was 37 years and most of patients (60.0%) were aged 40 years and below. The vast majority of the patients (80.4%) presented with haematemesis alone followed by malaena alone in 9.2% of cases. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking prior to the onset of bleeding was recorded in 7.9%, 51.7% and 38.3% of cases respectively. Previous history of peptic ulcer disease was reported in 22(9.2%) patients. Nine (3.8%) patients were HIV positive. The source of bleeding was accurately identified in 97.7% of patients. Diagnostic accuracy was greater within the first 24 h of the bleeding onset, and in the presence of haematemesis. Oesophageal varices were the most frequent cause of upper GI bleeding (51.3%) followed by peptic ulcers in 25.0% of cases. The majority of patients (60.8%) were treated conservatively. Endoscopic and surgical treatments were performed in 30.8% and 5.8% of cases respectively. 140 (58.3%) patients received blood transfusion. The median length of hospitalization was 8 days and it was significantly longer in patients who underwent surgical treatment and those with higher Rockall scores (P < 0.001). Rebleeding was reported in 3.3% of the patients. The overall mortality rate of 11.7% was significantly higher in patients with variceal bleeding, shock, hepatic decompensation, HIV infection, comorbidities, malignancy, age > 60 years and in patients with higher Rockall scores and those who underwent surgery (P < 0.001). Oesophageal varices are the commonest cause of upper gastrointestinal bleeding in our environment and it is associated with high morbidity and mortality. The diagnostic accuracy of fibreoptic endoscopy was related to the time interval between the onset of bleeding and endoscopy. Therefore, it is recommended that early endoscopy should be performed within 24 h of the onset of bleeding

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT

    Cytolytic DNA vaccine encoding lytic perforin augments the maturation of- and antigen presentation by- dendritic cells in a time-dependent manner

    Get PDF
    The use of cost-effective vaccines capable of inducing robust CD8+ T cell immunity will contribute significantly towards the elimination of persistent viral infections and cancers worldwide. We have previously reported that a cytolytic DNA vaccine encoding an immunogen and a truncated mouse perforin (PRF) protein significantly augments anti-viral T cell (including CD8+ T cell) immunity. Thus, the current study investigated whether this vaccine enhances activation of dendritic cells (DCs) resulting in greater priming of CD8+ T cell immunity. In vitro data showed that transfection of HEK293T cells with the cytolytic DNA resulted in the release of lactate dehydrogenase, indicative of necrotic/lytic cell death. In vitro exposure of this lytic cell debris to purified DCs from naïve C57BL/6 mice resulted in maturation of DCs as determined by up-regulation of CD80/CD86. Using activation/proliferation of adoptively transferred OT-I CD8+ T cells to measure antigen presentation by DCs in vivo, it was determined that cytolytic DNA immunisation resulted in a time-dependent increase in the proliferation of OT-I CD8+ T cells compared to canonical DNA immunisation. Overall, the data suggest that the cytolytic DNA vaccine increases the activity of DCs which has important implications for the design of DNA vaccines to improve their translational prospects.Danushka K. Wijesundara, Wenbo Yu, Ben J. C. Quah, Preethi Eldi, John D. Hayball, Kerrilyn R. Diener, Ilia Voskoboinik, Eric J. Gowans, and Branka Grubor-Bau

    Search for R-parity-violating supersymmetry in events with four or more leptons in sqrt(s) =7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for new phenomena in final states with four or more leptons (electrons or muons) is presented. The analysis is based on 4.7 fb−1 of s=7  TeV \sqrt{s}=7\;\mathrm{TeV} proton-proton collisions delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in two signal regions: one that requires moderate values of missing transverse momentum and another that requires large effective mass. The results are interpreted in a simplified model of R-parity-violating supersymmetry in which a 95% CL exclusion region is set for charged wino masses up to 540 GeV. In an R-parity-violating MSUGRA/CMSSM model, values of m 1/2 up to 820 GeV are excluded for 10 < tan β < 40

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentreofmassframeisusedtosuppressthelargemultijetbackground.ThecrosssectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques
    corecore