35 research outputs found
Past and Future Grand Challenges in Marine Ecosystem Ecology
International audienceFrontiers in Marine Science launched the Marine EcosystemsEcology (FMARS-MEE) section in2014, with a paper that identified eight grand challenges for the discipline (Borja, 2014). Sincethen, this section has published a total of 370 papers, including 336 addressing aspects of thosechallenges. As editors of the journal, with a wide range of marine ecology expertise, we felt it wastimely to evaluate research advances related to those challenges; and to update the scope of thesection to reflect the grand challenges we envision for the next 10 years. This output will matchwith the United Nations (UN) Decade on Oceans Science for Sustainable Development (DOSSD;Claudet et al., 2020), UN Decade of Ecosystems Restoration (DER;Young and Schwartz, 2019), andthe UN Sustainable Development Goals (SDGs;Visbeck et al., 2014
A global approach to mapping the environmental risk of commercial harbours on aquatic systems
The goal of this paper is to propose a screening method for assessing the environmental risk to aquatic systems in
harbours worldwide. A semi-quantitative method is based on environmental pressures, environmental conditions
and societal response. The method is flexible enough to be applied to 15 harbours globally distributed through a
multinational test using standardised and homogenised open data that can be obtained for any port worldwide.
The method emerges as a useful approach towards the foundation of a global environmental risk atlas of harbours
that should guide the harbour sector to develop a more globally informed strategy of sustainable
development
Ecological status assessment based on benthic macrofauna of three Mediterranean ports: Comparisons across seasons, activities and regions
A Dynamic Multiple Reaction Monitoring Analytical Method for the Determination of Fungicide Residues in Drinking Water
The extensive use of fungicides causes their continuous release into the environment through spraying, soil seepage, leaching, and runoff. It has been observed that their residues can be found in foods and a variety of environmental compartments, such as wastewater, lakes, rivers, sediments, drinking water sources (groundwater and surface water), treated water, and drinking water. A sensitive GC-MS/MS, using dynamic multiple reaction monitoring, an analytical method was developed to determine 10 fungicides (azoxystrobin, boscalid, captan, cyproconazole, cyprodinil, hexaconazole, metalaxyl, myclobutanil, paclobutrazol, and prochloraz) in drinking water. A solid-phase extraction method for sample preparations and validations was performed according to SANTE 2019 guidelines. All fungicides demonstrated mild or medium matrix effects (ME) ranging from 40.1% to 11.2%. Their recoveries ranged between 60% and 110%. The limits of detection were equal to or higher than 0.01 μg/L. The method was employed on 18 drinking water samples collected from public taps in Northern Evros, Greece, distributed in six sampling sites. Azoxystrobin, boscalid, cyproconazole, cypronidil, metalaxyl, and paclobutrazol mean concentrations did not surpass the allowable limit of 0.1 μg/L set by EU in any sampling site. Hexaconazole mean concentrations were higher than 0.1 μg/L in one sampling site, while prochloraz mean concentration showed limit exceedances in all sampling sites. Captan was not detected in any sampling site, and myclobutanil mean concentrations demonstrated exceedances of the permissible limit in four sampling sites. The presence of fungicide residues in the studied area is mainly due to the occasional point-sources pollution and preferential flow. Additionally, through the use of water, the risk of pesticides to human health was assessed for two different age groups. The sum of the hazard quotient values in each of the studied drinking water was less than unity. Consequently, the acute risk assessment procedure regards the examined drinking water as safe. Nevertheless, as prochloraz carcinogenic risk values were higher than the safe limit suggested by USEPA for both age groups, the existence of prochloraz residues raises concerns about chronic toxicity
The pros and cons of using micro-computed tomography in gross and microanatomical assessments of polychaetous annelids
Volume: 71Start Page: 237End Page: 24
Current clinical applications and potential perspective of micro-computed tomography in cardiovascular imaging: A systematic scoping review
Current clinical applications and potential perspective of micro-computed tomography in cardiovascular imaging: A systematic scoping review
Micro-computed tomography (micro-CT) constitutes an emerging imaging technique, which can be utilized in cardiovascular medicine to study in-detail the microstructure of heart and vessels. This paper aims to systematically review the clinical utility of micro-CT in cardiovascular imaging and propose future applications of micro-CT imaging in cardiovascular research. A systematic scoping review was conducted by searching for original studies written in English according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews. Medline, Scopus, ClinicalTrials.gov, and the Cochrane library were systematically searched through December 11, 2020 to identify publications concerning micro-CT applications in cardiovascular imaging. Preclinical-animal studies and case reports were excluded. The Newcastle-Ottawa assessment scale for observational studies was used to evaluate study quality. In total, the search strategy identified 30 studies that report on micro-CT–based cardiovascular imaging and satisfy our eligibility criteria. Across all included studies, the total number of micro-CT scanned specimens was 1,227. Six studies involved postmortem 3D-reconstruction of congenital heart defects, while eleven studies described atherosclerotic vessel (coronary or carotid) characteristics. Thirteen other studies employed micro-CT for the assessment of medical devices (mainly stents or prosthetic valves). In conclusion, micro-CT is a novel imaging modality, effectively adapted for the 3D visualization and analysis of cardiac soft tissues and devices at high spatial resolution. Its increasing use could make significant contributions to our improved understanding of the histopathophysiology of cardiovascular diseases, and, thus, has the potential to optimize interventional procedures and technologies, and ultimately improve patient outcomes
Volumetric Imaging of Lung Tissue at Micrometer Resolution: Clinical Applications of Micro-CT for the Diagnosis of Pulmonary Diseases
Micro-computed tomography (micro-CT) is a promising novel medical imaging modality that allows for non-destructive volumetric imaging of surgical tissue specimens at high spatial resolution. The aim of this study is to provide a comprehensive assessment of the clinical applications of micro-CT for the tissue-based diagnosis of lung diseases. This scoping review was conducted in accordance with the PRISMA Extension for Scoping Reviews, aiming to include every clinical study reporting on micro-CT imaging of human lung tissues. A literature search yielded 570 candidate articles, out of which 37 were finally included in the review. Of the selected studies, 9 studies explored via micro-CT imaging the morphology and anatomy of normal human lung tissue; 21 studies investigated microanatomic pulmonary alterations due to obstructive or restrictive lung diseases, such as chronic obstructive pulmonary disease, idiopathic pulmonary fibrosis, and cystic fibrosis; and 7 studies examined the utility of micro-CT imaging in assessing lung cancer lesions (n = 4) or in transplantation-related pulmonary alterations (n = 3). The selected studies reported that micro-CT could successfully detect several lung diseases providing three-dimensional images of greater detail and resolution than routine optical slide microscopy, and could additionally provide valuable volumetric insight in both restrictive and obstructive lung diseases. In conclusion, micro-CT-based volumetric measurements and qualitative evaluations of pulmonary tissue structures can be utilized for the clinical management of a variety of lung diseases. With micro-CT devices becoming more accessible, the technology has the potential to establish itself as a core diagnostic imaging modality in pathology and to enable integrated histopathologic and radiologic assessment of lung cancer and other lung diseases
Volumetric Imaging of Lung Tissue at Micrometer Resolution: Clinical Applications of Micro-CT for the Diagnosis of Pulmonary Diseases
Micro-computed tomography (micro-CT) is a promising novel medical imaging modality that allows for non-destructive volumetric imaging of surgical tissue specimens at high spatial resolution. The aim of this study is to provide a comprehensive assessment of the clinical applications of micro-CT for the tissue-based diagnosis of lung diseases. This scoping review was conducted in accordance with the PRISMA Extension for Scoping Reviews, aiming to include every clinical study reporting on micro-CT imaging of human lung tissues. A literature search yielded 570 candidate articles, out of which 37 were finally included in the review. Of the selected studies, 9 studies explored via micro-CT imaging the morphology and anatomy of normal human lung tissue; 21 studies investigated microanatomic pulmonary alterations due to obstructive or restrictive lung diseases, such as chronic obstructive pulmonary disease, idiopathic pulmonary fibrosis, and cystic fibrosis; and 7 studies examined the utility of micro-CT imaging in assessing lung cancer lesions (n = 4) or in transplantation-related pulmonary alterations (n = 3). The selected studies reported that micro-CT could successfully detect several lung diseases providing three-dimensional images of greater detail and resolution than routine optical slide microscopy, and could additionally provide valuable volumetric insight in both restrictive and obstructive lung diseases. In conclusion, micro-CT-based volumetric measurements and qualitative evaluations of pulmonary tissue structures can be utilized for the clinical management of a variety of lung diseases. With micro-CT devices becoming more accessible, the technology has the potential to establish itself as a core diagnostic imaging modality in pathology and to enable integrated histopathologic and radiologic assessment of lung cancer and other lung diseases.</jats:p
One Step forward: Benthic Pelagic Coupling and Indicators for Environmental Status
<div><p>A large data set from the Eastern Mediterranean was analyzed to explore the relationship between seawater column variables and benthic community status. Our results showed a strong quantitative link between the seawater column variables (Chlorophyll <i>a</i> and Eutrophication Index) and various indicators describing benthic diversity and community composition. The percentage of benthic opportunistic species increased significantly in the stations with high trophic status of the seawater column and so did the strength of the coupling between values of seawater column and benthic indicators. The Eutrophication Index threshold level of 0.85, separating the “Bad and Poor” from “Moderate to High” conditions could serve as an acceptable critical value above which there is a readily observable change in benthic community composition.</p></div