313 research outputs found
The need for standardised animal models and scoring systems in assessing mesh biocompatibility: Re: Hernia repair: the search for ideal meshes, S. Bringman et al. (2010) Hernia 14:81–87
Modified classification of surgical meshes for hernia repair based on the analyses of 1,000 explanted meshes
Outcomes of a prospective multi-center trial of a second-generation composite mesh for open ventral hernia repair
Multi-messenger observations of a binary neutron star merger
On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta
Umbilical hernia rupture with evisceration of omentum from massive ascites: a case report
<p>Abstract</p> <p>Introduction</p> <p>The incidence of hernias is increased in patients with alcoholic liver disease with ascites. To the best of our knowledge, this is the first report of an acute rise in intra-abdominal pressure from straining for stool as the cause of a ruptured umbilical hernia.</p> <p>Case presentation</p> <p>An 81-year-old Caucasian man with a history of alcoholic liver disease presented to our emergency department with an erythematous umbilical hernia and clear, yellow discharge from the umbilicus. On straining for stool, after initial clinical assessment, our patient noted a gush of fluid and evisceration of omentum from the umbilical hernia. An urgent laparotomy was performed with excision of the umbilicus and devitalized omentum.</p> <p>Conclusion</p> <p>We report the case of a patient with a history of alcoholic liver disease with ascites. Ascites causes a chronic increase in intra-abdominal pressure. A sudden increase in intra-abdominal pressure, such as coughing, vomiting, gastroscopy or, as in this case, straining for stool can cause rupture of an umbilical hernia. The presence of discoloration, ulceration or a rapid increase in size of the umbilical hernia signals impending rupture and should prompt the physician to reduce the intra-abdominal pressure.</p
Acute traumatic abdominal wall hernia
Although blunt abdominal trauma is frequent, traumatic abdominal wall hernias (TAWH) are rare. We describe a large TAWH with associated intra-abdominal lesions that were caused by high-energy trauma. The diagnosis was missed by clinical examination but was subsequently revealed by a computed tomography (CT) scan. Repair consisted of an open anatomical reconstruction of the abdominal wall layers with reinforcement by an intraperitoneal composite mesh. The patient recovered well and the results of a post-operative CT scan are presented
How to Get the Most out of Your Curation Effort
Large-scale annotation efforts typically involve several experts who may disagree with each other. We propose an approach for modeling disagreements among experts that allows providing each annotation with a confidence value (i.e., the posterior probability that it is correct). Our approach allows computing certainty-level for individual annotations, given annotator-specific parameters estimated from data. We developed two probabilistic models for performing this analysis, compared these models using computer simulation, and tested each model's actual performance, based on a large data set generated by human annotators specifically for this study. We show that even in the worst-case scenario, when all annotators disagree, our approach allows us to significantly increase the probability of choosing the correct annotation. Along with this publication we make publicly available a corpus of 10,000 sentences annotated according to several cardinal dimensions that we have introduced in earlier work. The 10,000 sentences were all 3-fold annotated by a group of eight experts, while a 1,000-sentence subset was further 5-fold annotated by five new experts. While the presented data represent a specialized curation task, our modeling approach is general; most data annotation studies could benefit from our methodology
Emergency percutaneous needle decompression for tension pneumoperitoneum
<p>Abstract</p> <p>Background</p> <p>Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic.</p> <p>Methods</p> <p>This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension.</p> <p>Results</p> <p>Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs), between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs). Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion), bridging the time to the start of the operation.</p> <p>Conclusions</p> <p>Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no definitive treatment, only a method to bridge the time gap to definitive surgical repair.</p
What are the risk factors of colonoscopic perforation?
<p>Abstract</p> <p>Background</p> <p>Knowledge of the factors influencing colonoscopic perforation (CP) is of decisive importance, especially with regard to the avoidance or minimization of the perforations. The aim of this study was to determine the incidence and risk factors of CP in one of the endoscopic training centers accredited by the World Gastroenterology Organization.</p> <p>Methods</p> <p>The prospectively collected data were reviewed of all patients undergoing either colonoscopy or flexible sigmoidoscopy at the Faculty of Medicine Siriraj Hospital, Bangkok, Thailand between January 2005 and July 2008. The incidence of CP was evaluated. Eight independent patient-, endoscopist- and endoscopy-related variables were analyzed by a multivariate model to determine their association with CP.</p> <p>Results</p> <p>Over a 3.5-year period, 10,124 endoscopic procedures of the colon (8,987 colonoscopies and 1,137 flexible sigmoidoscopies) were performed. There were 15 colonic perforations (0.15%). Colonoscopy had a slightly higher risk of CP than flexible sigmoidoscopy (OR 1.77, 95%CI 0.23-13.51; p = 1.0). Patient gender, emergency endoscopy, anesthetic method, and the specialty or experience of the endoscopist were not significantly predictive of CP rate. In multivariate analysis, patient age of over 75 years (OR = 6.24, 95%CI 2.26-17.26; p < 0.001) and therapeutic endoscopy (OR = 2.98, 95%CI 1.08-8.23; p = 0.036) were the only two independent risk factors for CP.</p> <p>Conclusion</p> <p>The incidence of CP in this study was 0.15%. Patient age of over 75 years and therapeutic colonoscopy were two important risk factors for CP.</p
- …
