477 research outputs found

    Venous thromboembolic events in critically ill traumatic brain injury patients

    Get PDF
    To estimate the prevalence, risk factors, prophylactic treatment and impact on mortality for venous thromboembolism (VTE) in patients with moderate to severe traumatic brain injury (TBI) treated in the intensive care unit. A post hoc analysis of the erythropoietin in traumatic brain injury (EPO-TBI) trial that included twice-weekly lower limb ultrasound screening. Venous thrombotic events were defined as ultrasound-proven proximal deep venous thrombosis (DVT) or clinically detected pulmonary embolism (PE). Results are reported as events, percentages or medians and interquartile range (IQR). Cox regression analysis was used to calculate adjusted hazard ratios (HR) with 95% confidence intervals (CI) for time to VTE and death. Of 603 patients, 119 (19.7%) developed VTE, mostly comprising DVT (102 patients, 16.9%) with a smaller number of PE events (24 patients, 4.0%). Median time to DVT diagnosis was 6 days (IQR 2-11) and to PE diagnosis 6.5 days (IQR 2-16.5). Mechanical prophylaxis (MP) was used in 91% of patients on day 1, 97% of patients on day 3 and 98% of patients on day 7. Pharmacological prophylaxis was given in 5% of patients on day 1, 30% of patients on day 3 and 57% of patients on day 7. Factors associated with time to VTE were age (HR per year 1.02, 95% CI 1.01-1.03), patient weight (HR per kg 1.01, 95% CI 1-1.02) and TBI severity according to the International Mission for Prognosis and Analysis of Clinical Trials risk of poor outcome (HR per 10% increase 1.12, 95% CI 1.01-1.25). The development of VTE was not associated with mortality (HR 0.92, 95% CI 0.51-1.65). Despite mechanical and pharmacological prophylaxis, VTE occurs in one out of every five patients with TBI treated in the ICU. Higher age, greater weight and greater severity of TBI increase the risk. The development of VTE was not associated with excess mortality.Peer reviewe

    Adjunctive Glucocorticoid Therapy in Patients with Septic Shock.

    Get PDF
    Background Whether hydrocortisone reduces mortality among patients with septic shock is unclear. Methods We randomly assigned patients with septic shock who were undergoing mechanical ventilation to receive hydrocortisone (at a dose of 200 mg per day) or placebo for 7 days or until death or discharge from the intensive care unit (ICU), whichever came first. The primary outcome was death from any cause at 90 days. Results From March 2013 through April 2017, a total of 3800 patients underwent randomization. Status with respect to the primary outcome was ascertained in 3658 patients (1832 of whom had been assigned to the hydrocortisone group and 1826 to the placebo group). At 90 days, 511 patients (27.9%) in the hydrocortisone group and 526 (28.8%) in the placebo group had died (odds ratio, 0.95; 95% confidence interval [CI], 0.82 to 1.10; P=0.50). The effect of the trial regimen was similar in six prespecified subgroups. Patients who had been assigned to receive hydrocortisone had faster resolution of shock than those assigned to the placebo group (median duration, 3 days [interquartile range, 2 to 5] vs. 4 days [interquartile range, 2 to 9]; hazard ratio, 1.32; 95% CI, 1.23 to 1.41; P<0.001). Patients in the hydrocortisone group had a shorter duration of the initial episode of mechanical ventilation than those in the placebo group (median, 6 days [interquartile range, 3 to 18] vs. 7 days [interquartile range, 3 to 24]; hazard ratio, 1.13; 95% CI, 1.05 to 1.22; P<0.001), but taking into account episodes of recurrence of ventilation, there were no significant differences in the number of days alive and free from mechanical ventilation. Fewer patients in the hydrocortisone group than in the placebo group received a blood transfusion (37.0% vs. 41.7%; odds ratio, 0.82; 95% CI, 0.72 to 0.94; P=0.004). There were no significant between-group differences with respect to mortality at 28 days, the rate of recurrence of shock, the number of days alive and out of the ICU, the number of days alive and out of the hospital, the recurrence of mechanical ventilation, the rate of renal-replacement therapy, and the incidence of new-onset bacteremia or fungemia. Conclusions Among patients with septic shock undergoing mechanical ventilation, a continuous infusion of hydrocortisone did not result in lower 90-day mortality than placebo. (Funded by the National Health and Medical Research Council of Australia and others; ADRENAL ClinicalTrials.gov number, NCT01448109 .)

    The 2009 multiwavelength campaign on Mrk 421: Variability and correlation studies

    Get PDF
    We performed a 4.5-month multi-instrument campaign (from radio to VHE gamma rays) on Mrk421 between January 2009 and June 2009, which included VLBA, F-GAMMA, GASP-WEBT, Swift, RXTE, Fermi-LAT, MAGIC, and Whipple, among other instruments and collaborations. Mrk421 was found in its typical (non-flaring) activity state, with a VHE flux of about half that of the Crab Nebula, yet the light curves show significant variability at all wavelengths, the highest variability being in the X-rays. We determined the power spectral densities (PSD) at most wavelengths and found that all PSDs can be described by power-laws without a break, and with indices consistent with pink/red-noise behavior. We observed a harder-when-brighter behavior in the X-ray spectra and measured a positive correlation between VHE and X-ray fluxes with zero time lag. Such characteristics have been reported many times during flaring activity, but here they are reported for the first time in the non-flaring state. We also observed an overall anti-correlation between optical/UV and X-rays extending over the duration of the campaign. The harder-when-brighter behavior in the X-ray spectra and the measured positive X-ray/VHE correlation during the 2009 multi-wavelength campaign suggests that the physical processes dominating the emission during non-flaring states have similarities with those occurring during flaring activity. In particular, this observation supports leptonic scenarios as being responsible for the emission of Mrk421 during non-flaring activity. Such a temporally extended X-ray/VHE correlation is not driven by any single flaring event, and hence is difficult to explain within the standard hadronic scenarios. The highest variability is observed in the X-ray band, which, within the one-zone synchrotron self-Compton scenario, indicates that the electron energy distribution is most variable at the highest energies.Comment: Accepted for publication in A&A, 18 pages, 14 figures (v2 has a small modification in the acknowledgments, and also corrects a typo in the field "author" in the metadata

    A connection between star formation activity and cosmic rays in the starburst galaxy M 82

    Full text link
    Although Galactic cosmic rays (protons and nuclei) are widely believed to be dominantly accelerated by the winds and supernovae of massive stars, definitive evidence of this origin remains elusive nearly a century after their discovery [1]. The active regions of starburst galaxies have exceptionally high rates of star formation, and their large size, more than 50 times the diameter of similar Galactic regions, uniquely enables reliable calorimetric measurements of their potentially high cosmic-ray density [2]. The cosmic rays produced in the formation, life, and death of their massive stars are expected to eventually produce diffuse gamma-ray emission via their interactions with interstellar gas and radiation. M 82, the prototype small starburst galaxy, is predicted to be the brightest starburst galaxy in gamma rays [3, 4]. Here we report the detection of >700 GeV gamma rays from M 82. From these data we determine a cosmic-ray density of 250 eV cm-3 in the starburst core of M 82, or about 500 times the average Galactic density. This result strongly supports that cosmic-ray acceleration is tied to star formation activity, and that supernovae and massive-star winds are the dominant accelerators.Comment: 18 pages, 4 figures; published in Nature; Version is prior to Nature's in-house style editing (differences are minimal

    A search for spectral hysteresis and energy-dependent time lags from X-ray and TeV gamma-ray observations of Mrk 421

    Get PDF
    Blazars are variable emitters across all wavelengths over a wide range of timescales, from months down to minutes. It is therefore essential to observe blazars simultaneously at different wavelengths, especially in the X-ray and gamma-ray bands, where the broadband spectral energy distributions usually peak. In this work, we report on three "target-of-opportunity" (ToO) observations of Mrk 421, one of the brightest TeV blazars, triggered by a strong flaring event at TeV energies in 2014. These observations feature long, continuous, and simultaneous exposures with XMM-Newton (covering X-ray and optical/ultraviolet bands) and VERITAS (covering TeV gamma-ray band), along with contemporaneous observations from other gamma-ray facilities (MAGIC and Fermi-LAT) and a number of radio and optical facilities. Although neither rapid flares nor significant X-ray/TeV correlation are detected, these observations reveal subtle changes in the X-ray spectrum of the source over the course of a few days. We search the simultaneous X-ray and TeV data for spectral hysteresis patterns and time delays, which could provide insight into the emission mechanisms and the source properties (e.g. the radius of the emitting region, the strength of the magnetic field, and related timescales). The observed broadband spectra are consistent with a one-zone synchrotron self-Compton model. We find that the power spectral density distribution at 4×104\gtrsim 4\times 10^{-4} Hz from the X-ray data can be described by a power-law model with an index value between 1.2 and 1.8, and do not find evidence for a steepening of the power spectral index (often associated with a characteristic length scale) compared to the previously reported values at lower frequencies.Comment: 45 pages, 15 figure

    Resuscitation fluid use in critically ill adults: an international cross-sectional study in 391 intensive care units

    Get PDF
    INTRODUCTION: Recent evidence suggests that choice of fluid used for resuscitation may influence mortality in critically ill patients. METHODS: We conducted a cross-sectional study in 391 intensive care units across 25 countries to describe the types of fluids administered during resuscitation episodes. We used generalized estimating equations to examine the association between patient, prescriber and geographic factors and the type of fluid administered (classified as crystalloid, colloid or blood products). RESULTS: During the 24-hour study period, 1,955 of 5,274 (37.1%) patients received resuscitation fluid during 4,488 resuscitation episodes. The main indications for administering crystalloid or colloid were impaired perfusion (1,526/3,419 (44.6%) of episodes), or to correct abnormal vital signs (1,189/3,419 (34.8%)). Overall, colloid was administered to more patients (1,234 (23.4%) versus 782 (14.8%)) and during more episodes (2,173 (48.4%) versus 1,468 (32.7%)) than crystalloid. After adjusting for patient and prescriber characteristics, practice varied significantly between countries with country being a strong independent determinant of the type of fluid prescribed. Compared to Canada where crystalloid, colloid and blood products were administered in 35.5%, 40.6% and 28.3% of resuscitation episodes respectively, odds ratios for the prescription of crystalloid in China, Great Britain and New Zealand were 0.46 (95% confidence interval (CI) 0.30 to 0.69), 0.18 (0.10 to 0.32) and 3.43 (1.71 to 6.84) respectively; odds ratios for the prescription of colloid in China, Great Britain and New Zealand were 1.72 (1.20 to 2.47), 4.72 (2.99 to 7.44) and 0.39 (0.21 to 0.74) respectively. In contrast, choice of fluid was not influenced by measures of illness severity (for example, Acute Physiology and Chronic Health Evaluation (APACHE) II score). CONCLUSIONS: Administration of resuscitation fluid is a common intervention in intensive care units and choice of fluid varies markedly between countries. Although colloid solutions are more expensive and may possibly be harmful in some patients, they were administered to more patients and during more resuscitation episodes than crystalloids were
    corecore