3,329 research outputs found
Black Hole Lightning from the Peculiar Gamma-Ray Loud Active Galactic Nucleus IC 310
The nearby active galaxy IC 310, located in the outskirts of the Perseus
cluster of galaxies is a bright and variable multi-wavelength emitter from the
radio regime up to very high gamma-ray energies above 100 GeV. Originally, the
nucleus of IC 310 has been classified as a radio galaxy. However, studies of
the multi-wavelength emission showed several properties similarly to those
found from blazars as well as radio galaxies. In late 2012, we have organized
the first contemporaneous multi-wavelength campaign including radio, optical,
X-ray and gamma-ray instruments. During this campaign an exceptionally bright
flare of IC 310 was detected with the MAGIC telescopes in November 2012
reaching an averaged flux level in the night of up to one Crab above 1 TeV with
a hard spectrum over two decades in energy. The intra-night light curve showed
a series of strong outbursts with flux-doubling time scales as fast as a few
minutes. The fast variability constrains the size of the gamma-ray emission
regime to be smaller than 20% of the gravitational radius of its central black
hole. This challenges the shock acceleration models, commonly used to explain
gamma-ray radiation from active galaxies. Here, we will present more details on
the MAGIC data and discuss several possible alternative emission models.Comment: 8 pages, 5 figures, Proceedings of the 34th International Cosmic Ray
Conference, 30 July - 6 August, 2015, The Hague, The Netherland
Families of spherical caps: spectra and ray limit
We consider a family of surfaces of revolution ranging between a disc and a
hemisphere, that is spherical caps. For this family, we study the spectral
density in the ray limit and arrive at a trace formula with geodesic polygons
describing the spectral fluctuations. When the caps approach the hemisphere the
spectrum becomes equally spaced and highly degenerate whereas the derived trace
formula breaks down. We discuss its divergence and also derive a different
trace formula for this hemispherical case. We next turn to perturbative
corrections in the wave number where the work in the literature is done for
either flat domains or curved without boundaries. In the present case, we
calculate the leading correction explicitly and incorporate it into the
semiclassical expression for the fluctuating part of the spectral density. To
the best of our knowledge, this is the first calculation of such perturbative
corrections in the case of curvature and boundary.Comment: 28 pages, 7 figure
Insights into the particle acceleration of a peculiar gamma -ray radio galaxy IC 310
IC 310 has recently been identified as a gamma-ray emitter based on
observations at GeV energies with Fermi-LAT and at very high energies (VHE, E >
100 GeV) with the MAGIC telescopes. Despite IC 310 having been classified as a
radio galaxy with the jet observed at an angle > 10 degrees, it exhibits a
mixture of multiwavelength properties of a radio galaxy and a blazar, possibly
making it a transitional object. On the night of 12/13th of November 2012 the
MAGIC telescopes observed a series of violent outbursts from the direction of
IC 310 with flux-doubling time scales faster than 5 min and a peculiar spectrum
spreading over 2 orders of magnitude. Such fast variability constrains the size
of the emission region to be smaller than 20% of the gravitational radius of
its central black hole, challenging the shock acceleration models, commonly
used in explanation of gamma-ray radiation from active galaxies. Here we will
show that this emission can be associated with pulsar-like particle
acceleration by the electric field across a magnetospheric gap at the base of
the jet.Comment: 2014 Fermi Symposium proceedings - eConf C14102.
A portable neutron spectroscope (NSPECT) for detection, imaging and identification of nuclear material
We have developed, fabricated and tested a prototype imaging neutron spectrometer designed for real-time neutron source location and identification. Real-time detection and identification is important for locating materials. These materials, specifically uranium and transuranics, emit neutrons via spontaneous or induced fission. Unlike other forms of radiation (e.g. gamma rays), penetrating neutron emission is very uncommon. The instrument detects these neutrons, constructs images of the emission pattern, and reports the neutron spectrum. The device will be useful for security and proliferation deterrence, as well as for nuclear waste characterization and monitoring. The instrument is optimized for imaging and spectroscopy in the 1-20 MeV range. The detection principle is based upon multiple elastic neutron-proton scatters in organic scintillator. Two detector panel layers are utilized. By measuring the recoil proton and scattered neutron locations and energies, the direction and energy spectrum of the incident neutrons can be determined and discrete and extended sources identified. Event reconstruction yields an image of the source and its location. The hardware is low power, low mass, and rugged. Its modular design allows the user to combine multiple units for increased sensitivity. We will report the results of laboratory testing of the instrument, including exposure to a calibrated Cf-252 source. Instrument parameters include energy and angular resolution, gamma rejection, minimum source identification distances and times, and projected effective area for a fully populated instrument
Recommended from our members
The Beagle 2 microscope
The Beagle 2 microscope provides optical images of the Martian surface at a resolution 5x higher than any other experiment currently planned. By using a novel illumination system it images in three colors and can also detect fluorescent materials
Cardiac magnetic resonance findings predict increased resource utilization in elective coronary artery bypass grafting
Morbidity following CABG (coronary artery bypass grafting) is difficult to predict and leads to increased healthcare costs. We hypothesized that pre-operative CMR (cardiac magnetic resonance) findings would predict resource utilization in elective CABG. Over a 12-month period, patients requiring elective CABG were invited to undergo CMR 1 day prior to CABG. Gadolinium-enhanced CMR was performed using a trueFISP inversion recovery sequence on a 1.5 tesla scanner (Sonata; Siemens). Clinical data were collected prospectively. Admission costs were quantified based on standardized actual cost/day. Admission cost greater than the median was defined as 'increased'. Of 458 elective CABG cases, 45 (10%) underwent pre-operative CMR. Pre-operative characteristics [mean (S.D.) age, 64 (9) years, mortality (1%) and median (interquartile range) admission duration, 7 (6–8) days] were similar in patients who did or did not undergo CMR. In the patients undergoing CMR, eight (18%) and 11 (24%) patients had reduced LV (left ventricular) systolic function by CMR [LVEF (LV ejection fraction) <55%] and echocardiography respectively. LE (late enhancement) with gadolinium was detected in 17 (38%) patients. The average cost/day was 19059 ($10891–157917). CMR LVEF {OR (odds ratio), 0.93 [95% CI (confidence interval), 0.87–0.99]; P=0.03} and SV (stroke volume) index [OR 1.07 (95% CI, 1.00–1.14); P=0.02] predicted increased admission cost. CMR LVEF (P=0.08) and EuroScore tended to predict actual admission cost (P=0.09), but SV by CMR (P=0.16) and LV function by echocardiography (P=0.95) did not. In conclusion, in this exploratory investigation, pre-operative CMR findings predicted admission duration and increased admission cost in elective CABG surgery. The cost-effectiveness of CMR in risk stratification in elective CABG surgery merits prospective assessment
High energy limits of Laplace-type and Dirac-type eigenfunctions and frame flows
We relate high-energy limits of Laplace-type and Dirac-type operators to
frame flows on the corresponding manifolds, and show that the ergodicity of
frame flows implies quantum ergodicity in an appropriate sense for those
operators. Observables for the corresponding quantum systems are matrix-valued
pseudodifferential operators and therefore the system remains non-commutative
in the high-energy limit. We discuss to what extent the space of stationary
high-energy states behaves classically.Comment: 26 pages, latex2
Efficient glueball simulations on anisotropic lattices
Monte Carlo results for the low-lying glueball spectrum using an improved,
anisotropic action are presented. Ten simulations at lattice spacings ranging
from 0.2 to 0.4 fm and two different anisotropies have been performed in order
demonstrate the advantages of using coarse, anisotropic lattices to calculate
glueball masses. Our determinations of the tensor (2++) and pseudovector (1+-)
glueball masses are more accurate than previous Wilson action calculations.Comment: 43 pages, LaTeX (with revtex). 13 postscript figures. Submitted to
Phys. Rev.
Bells as memorials in South Africa to the Great (1914-18) War
The contribution of South Africa to the allied cause in the Great War, and the sacrifice of so many lives of the White and Coloured populations, is memorialised on bells of the Cape Town carillon, on ringing, and on clock and other bells. The contribution of the Black population awaits recognition. Restoration of the Cape Town carillon so that it can again be played effectively, would be a fitting memorial to those who lost their lives in the non-combative roles that were open to the majority population of South Africa. Completion of the ring at what is now Queenstown cathedral would also be a fitting tribute to the bravery and unstinting service of so many South Africans during the Great War.Colin Lewis was Professor of Geography at Rhodes University, Grahamstown, South Africa from 1989 until his retirement at the end of 2007. In 1990, with the strong support of the incumbent Vice-Chancellor, Dr Derek Henderson, he instigated the Certificate in Change Ringing (Church Bell Ringing) in the Rhodes University Department of Music and Musicology - the first such course to be offered in Africa. Since that date he has lectured in the basic theory, and taught the practice of change ringing. He is the Ringing Master of the Cathedral of St Michael and St George, Grahamstown, South Africa
Evaluating changes in radiation treatment volumes from post-operative to same-day planning MRI in High-grade gliomas.
BACKGROUND: Adjuvant radiation therapy (RT) with temozolomide (TMZ) is standard of care for high grade gliomas (HGG) patients. RT is commonly started 3 to 5 weeks after surgery. The deformation of the tumor bed and brain from surgery to RT is poorly studied. This study examined the magnitude of volume change in the postoperative tumor bed and the potential impact of RT planning.
METHOD AND MATERIALS: This study includes 24 patients with HGG who underwent craniotomy and adjuvant RT with TMZ at our institution. All patients had immediate postoperative MRI and repeat MRI during the day of RT simulation. Gross tumor volumes (GTV), clinical target volumes (CTV) of initial 46 Gy (CTV1) and boost to 60 Gy (CTV2) were contoured on both sets of MRIs according to RTOG (Radiation Therapy Oncology Group) guidelines. For patients who recurred after RT, the recurrence pattern was evaluated.
RESULTS: An average of 17 days elapsed between immediate and delayed MRIs. GTV1 (FLAIR abnormality and tumor bed) decreased significantly on the delayed MRI as compared to immediate post-operative MRI (mean = 30.96cc, p = 0.0005), while GTV2 (contrast-enhanced T1 abnormality and tumor bed) underwent a non-significant increase (mean = 6.82cc, p = 0.07). Such changes lead to significant decrease of CTV1 (mean decrease is 113.9cc, p
CONCLUSION: The postoperative tumor bed of HGGs undergoes substantial volumetric changes after surgery. Treatment planning based on delayed MRI significantly reduces the volume of treated brain tissue without local control detriment. The marked reduction of volume treated to 46 Gy based on delayed MRI scan, could result in increased sparing of organs at risk. There may be a small risk of inadequate radiation field design if radiation planning is based on immediate post-operative MRI
- …
