20 research outputs found

    On the experimental intradiscal pressure measurement techniques : a review

    Get PDF
    Series : Mechanisms and machine science, ISSN 2211-0984, vol. 24The intradiscal pressure has been essential for prevent the spinal complaints by forming a basis for clinical advice to promote the correct sitting postures. As a consequence, it is evident the need of an accurate method for measure the intradiscal pressure, to better understand the disc response to hydorstatic pressure fluctuations. Numerous reviews regarding disc mechanics are available, including intradiscal pressure benchmarks; however, an analysis on the techniques of intradiscal pressure measurement is needed. Therefore, this review will remain focused on the methodologies adopted for measure the intradiscal pressure in several conditions: for different daily activities, under external loads and for values where occurs annulus fibrosus disruption. The importance of the intradiscal pressure on disc function will be discussed as well as the some guidelines for design new measurement techniques will be defined

    Bicycling crashes on streetcar (tram) or train tracks: mixed methods to identify prevention measures

    Full text link
    Abstract Background Streetcar or train tracks in urban areas are difficult for bicyclists to negotiate and are a cause of crashes and injuries. This study used mixed methods to identify measures to prevent such crashes, by examining track-related crashes that resulted in injuries to cyclists, and obtaining information from the local transit agency and bike shops. Methods We compared personal, trip, and route infrastructure characteristics of 87 crashes directly involving streetcar or train tracks to 189 crashes in other circumstances in Toronto, Canada. We complemented this with engineering information about the rail systems, interviews of personnel at seven bike shops about advice they provide to customers, and width measurements of tires on commonly sold bikes. Results In our study, 32 % of injured cyclists had crashes that directly involved tracks. The vast majority resulted from the bike tire being caught in the rail flangeway (gap in the road surface alongside rails), often when cyclists made unplanned maneuvers to avoid a collision. Track crashes were more common on major city streets with parked cars and no bike infrastructure, with left turns at intersections, with hybrid, racing and city bikes, among less experienced and less frequent bicyclists, and among women. Commonly sold bikes typically had tire widths narrower than the smallest track flangeways. There were no track crashes in route sections where streetcars and trains had dedicated rights of way. Conclusions Given our results, prevention efforts might be directed at individual knowledge, bicycle tires, or route design, but their potential for success is likely to differ. Although it may be possible to reach a broader audience with continued advice about how to avoid track crashes, the persistence and frequency of these crashes and their unpredictable circumstances indicates that other solutions are needed. Using tires wider than streetcar or train flangeways could prevent some crashes, though there are other considerations that lead many cyclists to have narrower tires. To prevent the majority of track-involved injuries, route design measures including dedicated rail rights of way, cycle tracks (physically separated bike lanes), and protected intersections would be the best strategy

    A review of impact testing methods for headgear in sports: considerations for improved prevention of head injury through research and standards

    Get PDF
    Standards for sports headgear were introduced as far back as the 1960s and many have remained substantially unchanged to present day. Since this time, headgear has virtually eliminated catastrophic head injuries such as skull fractures and changed the landscape of head injuries in sports. Mild traumatic brain injury (mTBI) is now a prevalent concern and the effectiveness of headgear in mitigating mTBI is inconclusive for most sports. Given that most current headgear standards are confined to attenuating linear head mechanics and recent brain injury studies have underscored the importance of angular mechanics in the genesis of mTBI, new or expanded standards are needed to foster headgear development and assess headgear performance that addresses all types of sport-related head and brain injuries. The aim of this review is to provide a basis for developing new sports headgear impact tests for standards by summarizing and critiquing: 1) impact testing procedures currently codified in published headgear standards for sports and 2) new or proposed headgear impact test procedures in published literature and/or relevant conferences. Research areas identified as needing further knowledge to support standards test development include defining sports-specific head impact conditions, establishing injury and age appropriate headgear assessment criteria, and the development of headgear specific head and neck surrogates for at-risk populations

    Biomechanical evaluation of the Total Facet Arthroplasty System (R) (TFAS(R)): loading as compared to a rigid posterior instrumentation system

    No full text
    Published online: 10 March 2012PURPOSE: To gain insight into a new technology, a novel facet arthroplasty device (TFAS) was compared to a rigid posterior fixation system (UCR). The axial and bending loads through the implants and at the bone-implant interfaces were evaluated using an ex vivo biomechanical study and matched finite element analysis. Kinematic behaviour has been reported for TFAS, but implant loads have not. Implant loads are important indicators of an implant's performance and safety. The rigid posterior fixation system is used for comparison due to the extensive information available about these systems. METHODS: Unconstrained pure moments were applied to 13 L3-S1 cadaveric spine segments. Specimens were tested intact, following decompression, UCR fixation and TFAS implantation at L4-L5. UCR fixation was via standard pedicle screws and TFAS implantation was via PMMA-cemented transpedicular stems. Three-dimensional 10 Nm moments and a 600 N follower load were applied; L4-L5 disc pressures and implant loads were measured using a pressure sensor and strain gauges, respectively. A finite element model was used to calculate TFAS bone-implant interface loads. RESULTS: UCR experienced greater implant loads in extension (p < 0.004) and lateral bending (p < 0.02). Under flexion, TFAS was subject to greater implant moments (p < 0.04). At the bone-implant interface, flexion resulted in the smallest TFAS (average = 0.20 Nm) but greatest UCR (1.18 Nm) moment and axial rotation resulted in the greatest TFAS (3.10 Nm) and smallest UCR (0.40 Nm) moments. Disc pressures were similar to intact for TFAS but not for UCR (p < 0.04). CONCLUSIONS: These results are most applicable to the immediate post-operative period prior to remodelling of the bone-implant interface since the UCR and TFAS implants are intended for different service lives (UCR--until fusion, TFAS--indefinitely). TFAS reproduced intact-like anterior column load-sharing--as measured by disc pressure. The highest bone-implant moment of 3.1 Nm was measured in TFAS and for the same loading condition the UCR interface moment was considerably lower (0.4 Nm). For other loading conditions, the differences between TFAS and UCR were smaller, with the UCR sometimes having larger values and for others the TFAS was larger. The long-term physiological meaning of these findings is unknown and demonstrates the need for a better understanding of the relationship between spinal arthroplasty devices and the host tissue as development of next generation motion-preserving posterior devices that hope to more accurately replicate the natural functions of the native tissue continues.Simon G. Sjovold, Qingan Zhu, Anton Bowden, Chad R. Larson, Peter M. de Bakker, Marta L. Villarraga, Jorge A. Ochoa, David M. Rosler, Peter A. Cripto
    corecore