2,392 research outputs found
Aneurismas Gigantes do Septo Interauricular Simulando Massas Quísticas. Dois Casos com Opções Terapêuticas Diferentes
With the recent technical improvement in echocardiography imaging (second harmonics) the number of interatrial septum aneurysms (ASA) increased and are easily recognized. We assist to an overdiagnosing number of cases and diagnostic criteria emerged to face this problem. In the great majority of the cases ASA are small and inoffensive, but as ASA is considered a risk factor for cardioembolism when associated with persistence of foramen oval (PFO), an examination by transesophageal echocardiography (TEE) for exclusion of PFO makes the sense and is a common testing in patients with cryptogenic stroke. Besides these frequent ASA, other forms exist; the authors describe two cases of uncommon and huge ASA, one mimicking a right atrial tumor and the other a quistic, hipoechoic mass. The first case was associated with mitral stenosis and was submitted to surgery and the second was closed with an Amplatzer occluder device usually used in atrial septal defect (ASD)
Patent Foramen Ovale Closure with the BioSTAR Bioabsorbable Implant
Os autores apresentam o caso clínico de
uma doente de 35 anos, sexo feminino, que
recorreu ao hospital da área da residência
por parésia do membro superior direito,
tendo sido diagnosticado AVC isquémico
por Ressonância Magnética Nuclear
Cranio-Encefálica (RMN-CE). A
investigação da fonte embólica levou ao
diagnóstico, por ecocardiograma
transesofágico, de foramen oval patente
(FOP), com shunt direito-esquerdo
espontâneo. Em Maio de 2009 foi efectuado encerramento percutâneo do FOP com dispositivo bioreabsorvível “BioSTAR®”, sob controlo ecocardiográfico. Efectuou ecocardiograma transtorácico após o primeiro, terceiro e sexto mês pós-procedimento e ecocardiograma transesofágico aos nove meses, mostrando sempre adequada
colocação do dispositivo, sem presença de
shunt residual, sem qualquer intercorrência clínica durante este período.
Os autores discutem a importância do
desenvolvimento de dispositivos
bioabsorvíveis para encerramento de FOP,
e as suas vantagens em comparação com os dispositivos sintéticos previamente
utilizados
Encerramento Percutâneo de Comunicação Interauricular Residual por Falência de Dispositivo
A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified this finding by showing a perforation of the device membrane coating. The patient underwent transcatheter closure of the residual shunt with a 20 mm Ultrasept PFO®device. The procedure was guided by fluoroscopy and real-time 3D TEE. At the end of the procedure 3D TEE documented correct device deployment with complete defect coverage and absence of residual shunt.info:eu-repo/semantics/publishedVersio
Percutaneous Occlusion of Vascular Malformations in Pediatric and Adult Patients: 20-Year Experience of a Single Center
OBJECTIVE:
A case series on different vascular malformations (VM) treated with percutaneous occlusion in children and adults is presented.
BACKGROUND:
Percutaneous occlusion is usually the preferred treatment method for VM. Previous series have mostly focused on single types of devices and/or VM.
METHODS:
Retrospective analysis of all patients who underwent percutaneous occlusion of VM in a single center, from 1995 to 2014, excluding patent ductus arteriosus. Clinical and angiographic data, procedural details, implanted devices, and complications were assessed. Procedural success was defined as effective device deployment with none or minimal residual flow. Predictors of procedural failure and complications were determined by multivariate analysis.
RESULTS:
A total of 123 VM were intervened in 47 patients with median age of 12 years (25 days-76 years). The VM included 55 pulmonary arteriovenous fistulae, 39 aortopulmonary collaterals, 10 systemic venovenous collaterals, 8 peripheral arteriovenous fistulae, 5 Blalock-Taussig shunts, 4 coronary fistulae, and 2 Fontan fenestrations. The 143 devices used included 80 vascular plugs, 38 coils, 22 duct occluders, and 3 foramen ovale or atrial septal defect occluders. Median vessel size was 4.5 (2.0-16.0) mm and device/vessel size ratio was 1.4 (1.1-2.0). Successful occlusion was achieved in 118 (95.9%) VM, including three reinterventions. Four (3.3%) clinically relevant complications occurred, without permanent sequelae. Lower body weight was independently associated with procedural failure and complications.
CONCLUSION:
To our knowledge, this is the largest series on different VM occluded percutaneously in children and adults, excluding patent ductus arteriosus. Percutaneous occlusion was effective and safe, using different devices.info:eu-repo/semantics/publishedVersio
Percutaneous Pulmonary Valve Implantation: Initial Experience
Os doentes com cardiopatias submetidos a
intervenção cirúrgica com implantação de
condutos entre o ventrículo direito e a
artéria pulmonar (VD-AP) podem desenvolver estenose e/ou insuficiência pulmonares ao longo do tempo. Nestas situações, associadas a arritmias cardíacas, disfunção ventricular direita e morte súbita, a re-intervenção cirúrgica permanece um desafio pela complexidade, mortalidade e morbilidade significativas. A implantação percutânea de válvulas pulmonares (IPVP), recentemente desenvolvida, representa uma abordagem alternativa para estes doentes.
Objectivo: Reportar a experiência inicial
com a IPVP, analisando o seu impacto no
manejo destes doentes.
Material e Métodos: Avaliação prospectiva
dos dados clínicos, ecocardiográficos, da
ressonância magnética, hemodinâmicos e
angiográficos dos doentes submetidos a
IPVP.
Resultados: Seis doentes em classe
funcional igual ou superior a II com
disfunção do conduto VD-AP foram submetidos a IPVP. Tinham todos evidência de insuficiência e 5/6 de estenose. O
procedimento consistiu na implantação de
stents não cobertos no conduto para reforçar
a sua rigidez e prevenir fracturas dos stents valvulados pulmonares Melody ® (Medtronic), que foram em seguida implantados com sucesso em todos. Obteve-se uma redução da pressão ventricular direita (94±27 para 44±7mmHg), da relação entre a pressão ventricular direita e esquerda (94±27 para 44±7%), do gradiente do conduto (65±28 para 11±4mmHg) e ausência de regurgitação pulmonar. O procedimento teve uma duração mediana de 180 minutos e decorreu sem complicações major. Os doentes tiveram alta em mediana dois dias após o procedimento.
Na última avaliação, em mediana 7,8 meses
após o procedimento, os doentes encontramse
em classe funcional I (5) ou II (1), sem
evidência não invasiva de disfunção do
conduto.
Conclusões: Os nossos resultados
acompanham a experiência actual com esta
modalidade terapêutica, com excelentes
resultados nestes grupo de doentes
complexos. A implementação da IPVP em
doentes com cardiopatia congénita que
requerem re-intervenção no tracto de saída
do ventrículo direito tem-se revelado uma
técnica promissora, embora complexa,
alternativa a mais uma intervenção cirúrgica
Percutaneous Closure of Atrial Septal Defects: a Decade of Experience at a Reference Center
INTRODUCTION: Atrial septal defects (ASD) are among the most common congenital anomalies and account for 10% of congenital heart disease in the pediatric age-group and 30% in adults. Closure is indicated when there is evidence of hemodynamic significance or after a paradoxical embolic event. Ten years ago, percutaneous closure became the treatment of choice in our center for all patients with a clear indication and favorable anatomy. In this paper we report the experience of this first decade.
OBJECTIVE: To assess the short- and long-term results of our ten-year experience with percutaneous closure of atrial septal defects.
METHODS: We studied retrospectively all patients with ASD treated with a percutaneous approach between November 1998 and December 2008. The pediatric age-group consisted of patients younger than 19 years old. Demographic data, clinical indications, minor and major complication rates, success rate and long-term outcome were assessed.
RESULTS: In the first ten years of experience 510 patients, of whom 166 were in the pediatric group, were treated in our center by a team of adult and pediatric cardiologists. The overall success rate of the procedure was 98% (97.5% in ASD and 99.5% in patent foramen ovale (PFO). The minor complication rate was 3% (3.4% in ASD and 2% in PFO). The most frequent complication was supraventricular tachycardia. The major complication rate was 1.2% (0.6% in ASD and 2% in PFO). Two patients developed cardiac tamponade due to hemopericardium that was resolved by pericardiocentesis, without need for surgery. One patient had an arterial pseudoaneurysm corrected by vascular surgery. There was no device embolization and no need for urgent surgery in this population. During follow-up two patients had recurrence of ischemic stroke, one had a transient ischemic attack and another had a hemorrhagic stroke. Mortality was 0.6% (0.6% in ASD and 0.5% in PFO). There were no in-hospital deaths. During follow-up there were two deaths, both in the adult group.
DISCUSSION AND CONCLUSION: In this population the success rate was high and most of the complications were minor. The results of this collaboration between adult and pediatric cardiologists in the first ten years of activity confirm the safety and efficacy of percutaneous closure of septal defects, when there is careful patient selection and a standardized technique
Magnetism, FeS colloids, and Origins of Life
A number of features of living systems: reversible interactions and weak
bonds underlying motor-dynamics; gel-sol transitions; cellular connected
fractal organization; asymmetry in interactions and organization; quantum
coherent phenomena; to name some, can have a natural accounting via
interactions, which we therefore seek to incorporate by expanding the horizons
of `chemistry-only' approaches to the origins of life. It is suggested that the
magnetic 'face' of the minerals from the inorganic world, recognized to have
played a pivotal role in initiating Life, may throw light on some of these
issues. A magnetic environment in the form of rocks in the Hadean Ocean could
have enabled the accretion and therefore an ordered confinement of
super-paramagnetic colloids within a structured phase. A moderate H-field can
help magnetic nano-particles to not only overcome thermal fluctuations but also
harness them. Such controlled dynamics brings in the possibility of accessing
quantum effects, which together with frustrations in magnetic ordering and
hysteresis (a natural mechanism for a primitive memory) could throw light on
the birth of biological information which, as Abel argues, requires a
combination of order and complexity. This scenario gains strength from
observations of scale-free framboidal forms of the greigite mineral, with a
magnetic basis of assembly. And greigite's metabolic potential plays a key role
in the mound scenario of Russell and coworkers-an expansion of which is
suggested for including magnetism.Comment: 42 pages, 5 figures, to be published in A.R. Memorial volume, Ed
Krishnaswami Alladi, Springer 201
Relationship between functional fitness, medication costs and mood in elderly people
Objective: to verify if functional fitness (FF) is associated with the annual cost of medication consumption and mood states (MSt) in elderly people. Methods: a cross-sectional study with 229 elderly people aged 65 years or more at Santa Casa de Misericórdia de Coimbra, Portugal. Seniors with physical and psychological limitations were excluded, as well as those using medication that limits performance on the tests. The Senior Fitness Test was used to evaluate FF, and the Profile of Mood States - Short Form to evaluate the MSt. The statistical analysis was based on Mancova, with adjustment for age, for comparison between men and women, and adjustment for sex, for comparison between cardiorespiratory fitness quintiles. The association between the variables under study was made with partial correlation, controlling for the effects of age, sex and body mass index. Results: an inverse correlation between cardiorespiratory fitness and the annual cost of medication consumption was found (p < 0.01). FF is also inversely associated with MSt (p < 0.05). Comparisons between cardiorespiratory fitness quintiles showed higher medication consumption costs in seniors with lower aerobic endurance, as well as higher deterioration in MSt (p < 0.01). Conclusion: elderly people with better FF and, specifically, better cardiorespiratory fitness present lower medication consumption costs and a more positive MSt
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
- …
