162 research outputs found
Bond between TRM versus FRP composites and concrete at high temperatures
The use of fibre reinforced polymers (FRP) as a means of external reinforcement for strengthening the existing reinforced concrete (RC) structures nowadays is the most common technique. However, the use of epoxy resins limits the effectiveness of FRP technique, and therefore, unless protective (thermal insulation) systems are provided, the bond capacity at the FRP-concrete interface will be extremely low above the glass transition temperature (Tg). To address problems associated with epoxies and to provide cost-effectiveness and durability of the strengthening intervention, a new composite cement- based material, namely textile-reinforced mortar (TRM) has been developed the last decade. This paper for the first time examines the bond performance between the TRM and concrete interfaces at high temperatures and, also compares for the first time the bond of both FRP and TRM systems to concrete at ambient and high temperatures. The key parameters investigated include: (a) the matrix used to impregnate the fibres, namely resin or mortar, resulting in two strengthening systems (TRM or FRP), (b) the level of high temperature to which the specimens are exposed (20, 50, 75, 100, and 150 °C) for FRP-reinforced specimens, and (20, 50, 75, 100, 150, 200, 300, 400, and 500 °C) for TRM-strengthened specimens, (c) the number of FRP/TRM layers (3 and 4), and (d) the loading conditions (steady state and transient conditions). A total of 68 specimens (56 specimens tested in steady state condition, and 12 specimens tested in transient condition) were constructed, strengthened and tested under double- lap direct shear. The result showed that overall TRM exhibited excellent performance at high temperature. In steady state tests, TRM specimens maintained an average of 85% of their ambient bond strength up to 400 °C, whereas the corresponding value for FRP specimens was only 17% at 150 °C. In transient test condition, TRM also outperformed over FRP in terms of both the time they maintained the applied load and the temperature reached before failure
Single-lap shear bond tests on Steel Reinforced Geopolymeric Matrix-concrete joints
YesNowadays Fiber Reinforced Polymers (FRPs) represent a well-established technique for rehabilitation of Reinforced Concrete (RC) and masonry structures. However, the severe degradation of mechanical properties of FRP under high temperature and fire as well as poor sustainability represents major weak points of organic-based systems. The use of eco-friendly inorganic geopolymeric matrices, alternative to the polymeric resins, would be highly desirable to overcome these issues. The present work aims to investigate the bond characteristic of a novel Steel Reinforced Geopolymeric Matrix (SRGM) strengthening system externally bonded to a concrete substrate having low mechanical properties. SRGM composite material consists of stainless steel cords embedded into a fireproof geopolymeric matrix. Single-lap shear tests by varying the bonded length were carried out. The main failure mode observed of SRGM-concrete joints was debonding at the fiber-matrix interface. Test results also suggest the effective bond length. On the basis of the experimental results, a cohesive bond-slip law was proposed.Part of the analyses were developed within the activities of Rete dei Laboratori Universitari di Ingegneria Sismica (ReLUIS) for the research program funded by the Dipartimento di Protezione Civile (DPC), Progetto DPC/ReLUIS 2016–AQ DPC/ReLUIS 2014–2016
Shear strengthening of concrete members with TRM jackets: Effect of shear span-to-depth ratio, material and amount of external reinforcement
An experimental work on reinforced concrete (RC) rectangular beams strengthened in shear with textile reinforced mortar (TRM) jackets is presented in this paper, with focus on the following investigated parameters: (a) the amount of external TRM reinforcement ratio, ρf, by means of using different number of textile layers and different types of textile fibre materials (carbon, glass, basalt); (b) the textile geometry, and (c) the shear span-to-depth ratio, a/d. In total, 22 tests were conducted on simply supported rectangular RC beams under (three-point bending) monotonic loading. The experimental results revealed that: (1) TRM is very effective when the failure is attributed to debonding of the TRM jacket from the concrete substrate; (2) the trend of effective strains for carbon, glass and basalt TRM jackets is descending for increasing values of the TRM reinforcement ratio, ρf, when failure is associated to debonding of the jacket; (3) the effect of textile geometry is significant only for low values of ρf, resulting in variances in the capacity enhancement and the failure modes, and (4) the shear span-to-depth ratio has practically no effect to the failure mode nor to the TRM jacket contribution to the total shear resistance of the RC beams
Stima conservativa dei valori residui dei parametri di risposta sismica. II: telai in c.a.
Experimental and analytical investigation on bond between Carbon-FRCM materials and masonry
- …
