3,850 research outputs found

    Improved Hamiltonian for Minkowski Yang-Mills Theory

    Get PDF
    I develop an improved Hamiltonian for classical, Minkowski Yang-Mills theory, which evolves infrared fields with corrections from lattice spacing aa beginning at O(a4)O(a^4). I use it to investigate the response of Chern-Simons number to a chemical potential, and to compute the maximal Lyapunov exponent. Both quantities have small aa limits, in both cases within 10%10\% of the limit found using the unimproved (Kogut Susskind) Hamiltonian. For the maximal Lyapunov exponent the limits differ by about 5%5 \% , significant at about 5σ5 \sigma, indicating that while a small aa limit exists, its value is corrupted by lattice artefacts. For the response of Chern-Simons number the statistics are not good enough to resolve 5% 5 \% differences, but it seems possible in analogy with the Lyapunov exponent that the final answer depends on the lattice regulation.Comment: Latex, 33 pages plus 2 .epsi figures included with psfig. Revised to include new data which weakens some original conclusion

    Magnetization of small lead particles

    Full text link
    The magnetization of an ensemble of isolated lead grains of sizes ranging from below 6 nm to 1000 nm is measured. A sharp disappearance of Meissner effect with lowering of the grain size is observed for the smaller grains. This is a direct observation by magnetization measurement of the occurrence of a critical particle size for superconductivity, which is consistent with Anderson's criterion.Comment: 7 pages, 5 figures, Submitted to PR

    Entflammungs- und Brandverhalten von biologischem Gewebe bei In-vitro-Bestrahlung mit dem CO2-Laser

    Get PDF
    Zusammenfassung: Fragestellung: Bei mikrolaryngoskopischen Eingriffen an den Atemwegen unter Anwendung von chirurgischen Laserstrahlen besteht eine Gefahr für Entflammungs- und Brandzwischenfälle. Selbst unter Weglassung von brennbaren Materialien liegt ein Restrisiko durch körpereigenes Gewebe vor, das unter der Einwirkung des Laserstrahls als partikelhaltiges Aerosol ("Lasersmog") im Operationsgebiet entsteht. Diese Untersuchung bezweckt die möglichst realitätsnahe Simulation dieses Phänomens und die Feststellung der Rahmenbedingungen, in denen eine Entflammungsgefahr vorliegt. Methodik: Zur Simulation des Operationsgebietes wurde in Anlehnung an die europäische Norm ISO-11990 eine zylinderförmige einseitig verschlossene Stahlkammer konstruiert, in die geeignete Schweinefleischstücke als Zielobjekt für die Laserbestrahlung eingeführt wurden. Mit einem Jetventilator wurde Beatmungsgas mit variabler Sauerstoffkonzentration in die Kammer eingelassen. Das Zielobjekt wurde mit Laserstrahlen unterschiedlicher Intensität und Zeitdauer im "Superpuls-Modus" (Impulsrate 250Hz) und mit einem Auftreffwinkel von 75° bestrahlt. Die Laserleistung wurde von 2-15W variiert, und Art, Dauer, Intensität sowie Häufigkeit von Entflammungs- und Brandphänomenen wurden dokumentiert. Ergebnisse: Es traten Brandphänomene, beginnend mit Funkenbildung bis zu anhaltendem Brand, auf. Die Intensität dieser Brandphänomene war bei fetthaltigem Gewebe höher als bei Muskulatur. Diese nahm auch bei Steigerung der Laserleistung und der Bestrahlungsdauer zu. Als wichtigster Faktor wurde die Sauerstoffkonzentration identifiziert: Der niedrigste Wert, bei dem ein Aufflammen auftrat, war 35% nach 42s bzw. 40% nach 20s. Höhere Konzentrationen als 60% führten fast sofort zu Funkenbildung und Aufflammen. Schlussfolgerungen: Bei der Anwendung von laserchirurgischen Techniken für Atemwegseingriffe unter Jetventilation liegt selbst bei Verwendung laserresistenter Materialien ein Risiko von Brandkomplikationen vor. Der vom Laserstrahl freigesetzte Lasersmog aus dem operierten Gewebe kann in einer sauerstoffreichen Atmosphäre entflammt werden. Um diese Gefahr zu vermindern, sind eine möglichst tiefe Sauerstoffkonzentration im Beatmungsgas (<40%), eine niedrigstmögliche Laserleistung (<6W) und eine Begrenzung der Dauer der einzelnen Laserimpulse (<10s) einzuhalte

    Entflammungs- und Brandverhalten von biologischem Gewebe bei In-vitro-Bestrahlung mit dem CO2-Laser

    Get PDF
    Zusammenfassung: Fragestellung: Bei mikrolaryngoskopischen Eingriffen an den Atemwegen unter Anwendung von chirurgischen Laserstrahlen besteht eine Gefahr für Entflammungs- und Brandzwischenfälle. Selbst unter Weglassung von brennbaren Materialien liegt ein Restrisiko durch körpereigenes Gewebe vor, das unter der Einwirkung des Laserstrahls als partikelhaltiges Aerosol ("Lasersmog") im Operationsgebiet entsteht. Diese Untersuchung bezweckt die möglichst realitätsnahe Simulation dieses Phänomens und die Feststellung der Rahmenbedingungen, in denen eine Entflammungsgefahr vorliegt. Methodik: Zur Simulation des Operationsgebietes wurde in Anlehnung an die europäische Norm ISO-11990 eine zylinderförmige einseitig verschlossene Stahlkammer konstruiert, in die geeignete Schweinefleischstücke als Zielobjekt für die Laserbestrahlung eingeführt wurden. Mit einem Jetventilator wurde Beatmungsgas mit variabler Sauerstoffkonzentration in die Kammer eingelassen. Das Zielobjekt wurde mit Laserstrahlen unterschiedlicher Intensität und Zeitdauer im "Superpuls-Modus" (Impulsrate 250Hz) und mit einem Auftreffwinkel von 75° bestrahlt. Die Laserleistung wurde von 2-15W variiert, und Art, Dauer, Intensität sowie Häufigkeit von Entflammungs- und Brandphänomenen wurden dokumentiert. Ergebnisse: Es traten Brandphänomene, beginnend mit Funkenbildung bis zu anhaltendem Brand, auf. Die Intensität dieser Brandphänomene war bei fetthaltigem Gewebe höher als bei Muskulatur. Diese nahm auch bei Steigerung der Laserleistung und der Bestrahlungsdauer zu. Als wichtigster Faktor wurde die Sauerstoffkonzentration identifiziert: Der niedrigste Wert, bei dem ein Aufflammen auftrat, war 35% nach 42s bzw. 40% nach 20s. Höhere Konzentrationen als 60% führten fast sofort zu Funkenbildung und Aufflammen. Schlussfolgerungen: Bei der Anwendung von laserchirurgischen Techniken für Atemwegseingriffe unter Jetventilation liegt selbst bei Verwendung laserresistenter Materialien ein Risiko von Brandkomplikationen vor. Der vom Laserstrahl freigesetzte Lasersmog aus dem operierten Gewebe kann in einer sauerstoffreichen Atmosphäre entflammt werden. Um diese Gefahr zu vermindern, sind eine möglichst tiefe Sauerstoffkonzentration im Beatmungsgas (<40%), eine niedrigstmögliche Laserleistung (<6W) und eine Begrenzung der Dauer der einzelnen Laserimpulse (<10s) einzuhalte

    Chemical equilibration and thermal dilepton production from the quark gluon plasma at finite baryon density

    Get PDF
    The chemical equilibration of a highly unsaturated quark-gluon plasma has been studied at finite baryon density. It is found that in the presence of small amount of baryon density, the chemical equilibration for gluon becomes slower and the temperature decreases less steeply as compared to the baryon free plasma. As a result, the space time integrated yield of dilepton is enhanced if the initial temperature of the plasma is held fixed. Even at a fixed initial energy density, the suppression of the dilepton yields at higher baryo-chemical potential is compensated, to a large extent, by the slow cooling of the plasma.Comment: Latex, 19 pages, 8 postscript figures. To appear in Phys. Rev.

    High-frequency jet ventilation for minimizing breathing-related liver motion during percutaneous radiofrequency ablation of multiple hepatic tumours

    Get PDF
    Movements of the liver caused by spontaneous breathing (during sedation or local anaesthesia) or by ventilation during anaesthesia are a source of concern in CT-guided procedures because of the limited spatial and contrast resolution of unenhanced imaging, artifacts caused by the probes and the relatively low temporal resolution of the fluoroscopy mode. During CT-guided radiofrequency ablation (RFA), it is essential that the lesion can be visualized optimally and that the ablation probe is positioned accurately to avoid non-target injuries. We therefore used high-frequency jet ventilation and general anaesthesia to minimize ventilation-related liver movement and provide optimal conditions for a patient undergoing RFA of hepatic metastases. The technical and anaesthetic considerations are discussed, and a specific limitation of transcutaneous Pco2 measurement during activation of the ablation is reported for the first tim

    Enhancement of gluonic dissociation of J/ψJ/\psi in viscous QGP

    Full text link
    We have investigated the effect of viscosity on the gluonic dissociation of J/ψJ/\psi in an equilibrating plasma. Suppression of J/ψJ/\psi due to gluonic dissociation depend on the temperature and also on the chemical equilibration rate. In an equilibrating plasma, viscosity affects the temperature evolution and also the chemical equilibration rate, requiring both of them to evolve slowly compared to their ideal counter part. For Au+Au collisions at RHIC and LHC energies, gluonic dissociation of J/ψJ/\psi increases for a viscous plasma. Low PTP_T J/ψJ/\psi's are found to be more suppressed due to viscosity than the high PTP_T ones. Also the effect is more at LHC energy than at RHIC energy.Comment: 3 pages, 1 figur

    Chaotic Symmetry Breaking and Dissipative Two-Field Dynamics

    Full text link
    The dynamical symmetry breaking in a two-field model is studied by numerically solving the coupled effective field equations. These are dissipative equations of motion that can exhibit strong chaotic dynamics. By choosing very general model parameters leading to symmetry breaking along one of the field directions, the symmetry broken vacua make the role of transitory strange attractors and the field trajectories in phase space are strongly chaotic. Chaos is quantified by means of the determination of the fractal dimension, which gives an invariant measure for chaotic behavior. Discussions concerning chaos and dissipation in the model and possible applications to related problems are given.Comment: 18 pages, 2 .eps figures (uses epsf), Revtex. A much larger version, more comments, refs. and results. Version in press Physical Review

    Influence of airway‐occluding instruments on airway pressure during jet ventilation for rigid bronchoscopy

    Get PDF
    We measured changes in airway pressure (Paw) caused by microsurgical instruments introduced into a rigid bronchoscope during high frequency jet ventilation (HFJV). With approval of the institutional Ethics Committee, 10 adults undergoing elective tracheobronchial endoscopy and endosonography during general anaesthesia were investigated. Inflation of an endosonography probe balloon in the left main stem bronchus caused airway obstruction. Pressure measurements proximal and distal to the obstruction were compared after three degrees of obstruction (0%, 50% and 90%) and with two different driving pressure settings. Airway obstruction increased the mean (sd) peak inspiratory pressure (PIP) from 7.5 (2.6) to 9.5 (3.5) mm Hg for 2 atm (P=0.0008) and from 9.7 (3.7) to 13.0 (5.1) mm Hg for 3 atm (P=0.0001). Airway obstruction did not alter peripheral PIP (7.2 (4.1) to 7.1 (3.7) mm Hg for 2 atm and 8.8 (4.3) to 9.4 (5.2) mm for 3 atm), but resulted in an end‐expiratory pressure (EEP) beyond the narrowing being significantly greater than in the unobstructed airway (2.5 (3.4) to 5.5 (3.7) mm Hg for 2 atm; P=0.0005) and 3.2 (3.6) to 8.0 (4.3) mm for 3 atm; P<0.0001). Severe airway narrowing increases inspiratory pressure proximal and expiratory pressure distal to the obstruction in relation to the applied driving pressure. Since the distal EEP never exceeded PIP, even near‐total airway obstruction should not cause severe lung distension or barotrauma in subjects with normal lungs. Br J Anaesth 2000; 85: 463-
    corecore