1,565 research outputs found
Studies of fiber-matrix adhesion on compression strength
A study was initiated on the effect of the matrix polymer and the fiber matrix bond strength of carbon fiber polymer matrix composites. The work includes tests with micro-composites, single ply composites, laminates, and multi-axial loaded cylinders. The results obtained thus far indicate that weak fiber-matrix adhesion dramatically reduces 0 degree compression strength. Evidence is also presented that the flaws in the carbon fiber that govern compression strength differ from those that determine fiber tensile strength. Examination of post-failure damage in the single ply tests indicates kink banding at the crack tip
On the Lagrangian structure of 3D consistent systems of asymmetric quad-equations
Recently, the first-named author gave a classification of 3D consistent
6-tuples of quad-equations with the tetrahedron property; several novel
asymmetric 6-tuples have been found. Due to 3D consistency, these 6-tuples can
be extended to discrete integrable systems on Z^m. We establish Lagrangian
structures and flip-invariance of the action functional for the class of
discrete integrable systems involving equations for which some of the
biquadratics are non-degenerate and some are degenerate. This class covers,
among others, some of the above mentioned novel systems.Comment: 21 pp, pdfLaTe
Blind Normalization of Speech From Different Channels
We show how to construct a channel-independent representation of speech that
has propagated through a noisy reverberant channel. This is done by blindly
rescaling the cepstral time series by a non-linear function, with the form of
this scale function being determined by previously encountered cepstra from
that channel. The rescaled form of the time series is an invariant property of
it in the following sense: it is unaffected if the time series is transformed
by any time-independent invertible distortion. Because a linear channel with
stationary noise and impulse response transforms cepstra in this way, the new
technique can be used to remove the channel dependence of a cepstral time
series. In experiments, the method achieved greater channel-independence than
cepstral mean normalization, and it was comparable to the combination of
cepstral mean normalization and spectral subtraction, despite the fact that no
measurements of channel noise or reverberations were required (unlike spectral
subtraction).Comment: 25 pages, 7 figure
Влияние импульсных магнитных полей на электрические и прочностные характеристики полимерной изоляции кабелей
Services surround you:physical-virtual linkage with contextual bookmarks
Our daily life is pervaded by digital information and devices, not least the common mobile phone. However, a seamless connection between our physical world, such as a movie trailer on a screen in the main rail station and its digital counterparts, such as an online ticket service, remains difficult. In this paper, we present contextual bookmarks that enable users to capture information of interest with a mobile camera phone. Depending on the user’s context, the snapshot is mapped to a digital service such as ordering tickets for a movie theater close by or a link to the upcoming movie’s Web page
Recommended from our members
Demagnetization study of pulse-field magnetized bulk superconductors
GdBa2Cu3O7-δ bulk superconductors are a route to higher magnetic fields in rotating machines. Here we examine the resistance of pulse-field magnetized bulks to the demagnetization fields they may experience in such a system. The bulks were magnetized at 77 K, after which several thousand cycles of AC field were applied. Subsequently, the decay of the trapped field was characterized. We found the decay per cycle decreases with frequency and is, normalized to the initial trapped field, largest at the edge of the bulk. At 77 K the reduction in trapped field proved significant (25% in the center for 150 mT (peak) AC field at 6 Hz), however reducing below 1% when lowering the temperature to 60 K. We explain this observation as being due to increased flux pinning strength at low temperatures. When applying an AC field we found a temperature rise that increased with applied field amplitude and frequency. However, when applying an AC field of amplitude 45 mT with a frequency of 48 Hz we found an increase of the bulk temperature of only 100 mK. Therefore, we conclude the temperature rise within the analyzed AC field frequency and amplitude range does not contribute significantly to the decay of trapped field
Doppler Shifted Internal Waves in a Shallow Water Region
Measurements of velocity fields from a high frequency ( 1.2 MHz) vertical acoustic doppler current profiler (V ADCP) along with density and temperature profiles were taken in coastal waters on the New Jersey shelf. Time series span six consecutive months from May through October 2003, capturing the transition of the water column from a highly stratified summer into a fully mixed winter season. Barotropic tides interact with variations in local bathymetry causing disturbances within the fluid medium which govern internal wave characteristics. During the months of June, July, and August, a high number of internal wave signals were observed. Spectra from depth averaged vertical velocities have a relatively constant structure for frequencies greater than 36 h-1 until reaching the cut-off frequency of 90 h-1 . Wave periods ranged from 40 s to 15 min with variability mostly due to fluctuations in regional dynamics. Evidence supports propagating internal waves in the direction of the bathymetric gradient towards shore. Wavelet analysis of depth averaged vertical signals reveal an alteration in frequency that has a period comparable to the tidal cycle. Peaks in frequencies were observed near high tide before decreasing back to a lower value. More than 70 of these instances occurred during the data collection period. Evidence supports Doppler shifted internal waves by the horizontal moving tide. The observation of this unique phenomenon provided motivation for this study. The scope of this work analyzes one such occurrence in detail followed by the inspection of values averaged over the month of August. Analysis techniques include evaluating water column properties, correlations between instrumentation, along with the examination of theoretical models
Molecular weight of hydroxyethyl starch: is there an effect on blood coagulation and pharmacokinetics?
Background. The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods. Thirty pigs were infused with three different HES solutions (20 ml kg−1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results. Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre−1, P<0.001, 1701 (321) g min litre−1, P<0.001] than HES 130 [1156 (223) g min litre−1] and alpha half life (\batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \end{document}) was longer for HES 500 [53.8 (8.6) min, P<0.01] and HES 900 [57.1 (12.3) min, P<0.01] than for HES 130 [39.9 (10.7) min]. Beta half life (\batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \end{document}), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight low-substituted HES might result in a longer lasting volume effec
- …
