2,068 research outputs found
Temperature dependence of absorption in photorefractive iron-doped lithium niobate crystals
We present experimental data showing a significant dependence of light absorption on temperature in photorefractive LiNbO3:Fe crystals. The results are successfully explained by assuming that the widths of the Fe2+ absorption bands in the visible and in the infrared spectral region depend on temperature. The findings are of relevance for thermal fixing of holograms. Furthermore, a temperature-induced increase of the infrared absorption is promising for improved infrared recording
Investigation of nonlinear absorption processes with femtosecond light pulses in lithium niobate crystals
The propagation of high-power femtosecond light pulses in lithium niobate crystals (LiNbO3) is investigated experimentally and theoretically in collinear pump-probe transmission experiments. It is found within a wide intensity range that a strong decrease of the pump transmission coefficient at wavelength 388 nm fully complies with the model of two-photon absorption; the corresponding nonlinear absorption coefficient is betap~=3.5 cm/GW. Furthermore, strong pump pulses induce a considerable absorption for the probe at 776 nm. The dependence of the probe transmission coefficient on the time delay Deltat between probe and pump pulses is characterized by a narrow dip (at Deltat~=0) and a long (on the picosecond time scale) lasting plateau. The dip is due to direct two-photon transitions involving pump and probe photons; the corresponding nonlinear absorption coefficient is betar~=0.9 cm/GW. The plateau absorption is caused by the presence of pump-excited charge carriers; the effective absorption cross section at 776 nm is sigmar~=8×10^–18 cm^2. The above nonlinear absorption parameters are not strongly polarization sensitive. No specific manifestations of the relaxation of hot carriers are found for a pulse duration of ~=0.24 ps
Femtosecond time-resolved absorption processes in lithium niobate crystals
emtosecond pump pulses are strongly attenuated in lithium niobate owing to two-photon absorption; the relevant nonlinear coefficient beta_p ranges from ~3.5 cm/GW for lambda_p = 388 nm to ~0.1 cm/GW for 514 nm. In collinear pump-probe experiments the probe transmission at the double pump wavelength 2lambda_p=776 nm is controlled by two different processes: A direct absorption process involving pump and probe photons (beta_r ~ or = 0.9 cm/GW) leads to a pronounced short-duration transmission dip, whereas the probe absorption by pump-excited charge carriers results in a long-duration plateau. Coherent pump-probe interactions are of no importance. Hot-carrier relaxation occurs on the time scale of < or ~0.1 ps
Trapping of dielectric particles with light-induced space-charge fields
Light-induced space-charge fields in lithium niobate crystals are used to trap and manipulate dielectric particles on the surface of such crystals. Without any external voltage source, strong field gradients are present in the proximity of the crystal surface. These are used to trap particles with diameters in the range between 100 nm and some tens of micrometers
Highly tunable low-threshold optical parametric oscillation in radially poled whispering gallery resonators
Whispering gallery resonators (WGR's), based on total internal reflection,
possess high quality factors in a broad spectral range. Thus, nonlinear optical
processes in such cavities are ideally suited for the generation of broadband
or tunable electromagnetic radiation. Experimentally and theoretically, we
investigate the tunability of optical parametric oscillation in a radially
structured WGR made of lithium niobate. With a 1.04 /mum pump wave, the signal
and idler waves are tuned from 1.78 to 2.5 \mum - including the point of
degeneracy - by varying the temperature between 20 and 62 {\deg}C. A weak
off-centering of the radial domain structure extends considerably the tuning
capabilities. The oscillation threshold lies in the mW-power range.Comment: 4 pages, 5 figure
Role of cerium in lithium niobate for holographic recording
Cerium-doped lithium niobate crystals are tested for holographic recording. A photochromic effect is observed in crystals doped with cerium and manganese. But two-center recording in the sample is not as effective as in iron and manganese doubly doped crystals. Photocurrent measurements in cerium and iron singly doped crystals indicate that the photovoltaic constant in the cerium-doped crystal is only one third of that of the iron-doped one. This is the main reason accounting for the low sensitivity of cerium-doped lithium niobate crystals. However, in the diffusion dominated case, i.e., for reflection geometry, cerium-doped lithium niobate may give a strong effect
Unpacking ‘women’s health’ in the context of PPPs: a return to instrumentalism in development policy and practice?
There has been a significant increase in funding for health programmes in development over the last two decades, partly due to the formation of public–private partnerships. This article examines the impact of public–private partnerships from the perspective of women’s health, asks whether the current culture of funding has led to an increased instrumentalism in women’s health programming and what effects this has on how women’s health is addressed at the level of practice. The article is based on research carried out with UK-based non-governmental organisations (NGOs), and its conclusions raise further challenges for improving women’s health policies and programmes in development
Novel measures of inflammation and insulin resistance are related to obesity and fitness in a diverse sample of 11-14 year-olds:The HEALTHY Study
BACKGROUND: GlycA is a novel serum marker of systemic inflammation. There is no information on GlycA in pediatric populations, how it differs by gender or its association with body mass index (BMI) or fitness. LP-IR is a serum measure of insulin resistance which is related to changes in BMI group in adolescents, but its relationship with fitness is unknown. The current study examined the independent associations between fitness and BMI with GlycA and LP-IR among US adolescents.
METHODS: Participants were 1664 US adolescents from the HEALTHY study with complete 6th and 8th grade BMI, fitness and blood data. GlycA and LP-IR were measured by NMR spectroscopy. Three BMI groups and three fitness groups were created. Linear mixed models examined associations between GlycA, LP-IR, fitness and BMI.
RESULTS: LP-IR decreased between 6th and 8th grade. GlycA increased among girls but decreased among boys. At 8th grade, median GlycA values were 27 (7.6%) μmol/l higher (381 versus 354) for girls than boys. Median GlycA 6th grade values were 9% higher in obese girls than healthy weight girls. Overall there was strong evidence (P
CONCLUSIONS: GlycA was associated with BMI and fitness among in US adolescents. These findings suggest that there are independent effects for BMI and fitness group with both GlycA and LP-IR. Future studies should validate the role of GlycA and LP-IR to evaluate the effects of interventions to modify obesity and fitness in order to improve systemic inflammation and insulin resistance.International Journal of Obesity accepted article preview online, 04 May 2016. doi:10.1038/ijo.2016.84
Выбор оптимальных технических решений для улавливания углеводородных паров от резервуарных парков нефти
San Francisco, CA - US
Remifentanil does not impair left ventricular systolic and diastolic function in young healthy patients
Background Experimental studies and investigations in patients with cardiac diseases suggest that opioids at clinical concentrations have no important direct effect on myocardial relaxation and contractility. In vivo data on the effect of remifentanil on myocardial function in humans are scarce. This study aimed to investigate the effects of remifentanil on left ventricular (LV) function in young healthy humans by transthoracic echocardiography (TTE). We hypothesized that remifentanil does not impair systolic, diastolic LV function, or both. Methods Twelve individuals (aged 18-48 yr) without any history or signs of cardiovascular disease and undergoing minor surgical procedures under general anaesthesia were studied. Echocardiographic examinations were performed in the spontaneously breathing subjects before (baseline) and during administration of remifentanil at a target effect-site concentration of 2 ng ml−1 by target-controlled infusion. Analysis of systolic function focused on fractional area change (FAC). Analysis of diastolic function focused on peak early diastolic velocity of the mitral annulus (e′) and on transmitral peak flow velocity (E). Results Remifentanil infusion at a target concentration of 2 ng ml−1 did not affect heart rate or arterial pressure. There was no evidence of systolic or diastolic dysfunction during remifentanil infusion, as the echocardiographic measure of systolic function (FAC) was similar to baseline, and measures of diastolic function remained unchanged (e′) or improved slightly (E). Conclusion Continuous infusion of remifentanil in a clinically relevant concentration did not affect systolic and diastolic LV function in young healthy subjects during spontaneous breathing as indicated by TT
- …
