256 research outputs found
A new multi-spectral imaging system for examining paintings
A new multispectral system developed at the National Gallery is presented. The system is capable of measuring the spectral reflectance per pixel of a painting. These spectra are found to be almost as accurate as those recorded with a spectrophotometer; there is no need for any spectral reconstruction apart from a simple cubic interpolation between measured points. The procedure for recording spectra is described and the accuracy of the system is quantified. An example is presented of the use of the system to scan a painting of St. Mary Magdalene by Crivelli. The multispectral data are used in an attempt to identify some of the pigments found in the painting by comparison with a library of spectra obtained from reference pigments using the same system. In addition, it is shown that the multispectral data can be used to render a color image of the original under a chosen illuminant and that interband comparison can help to elucidate features of the painting, such as retouchings and underdrawing, that are not visible in trichromatic images
SIRIS: a high resolution scanning infrared camera for examining paintings
The new SIRIS (Scanning InfraRed Imaging System) camera developed at the National Gallery in London allows highresolution images of paintings to be made in the near infrared region (900–1700 nm). Images of 5000 × 5000 pixels are made by moving a 320 × 256 pixel InGaAs array across the focal plane of the camera using two orthogonal translation stages. The great advantages of this camera over scanning infrared devices are its relative portability and that image acquisition is comparatively rapid – a full 5000 × 5000 pixel image can be made in around 20 minutes. The paper describes the development of the mechanical, optical and electronic components of the camera, including the design of a new lens. The software routines used to control image capture and to assemble the individual 320 × 256 pixel frames into a seamless mosaic image are also mentioned. The optics of the SIRIS camera have been designed so that the camera can operate at a range of resolutions; from around 2.5 pixels per millimetre on large paintings of up to 2000 × 2000 mm to 10 pixels per millimetre on smaller paintings or details of paintings measuring 500 × 500 mm. The camera is primarily designed to examine underdrawings in paintings; preliminary results from test targets and paintings are presented and the quality of the images compared with those from other cameras currently used in this field
Optical coherence tomography- a non-invasive technique applied to conservation of paintings
It is current practice to take tiny samples from a painting to mount and examine in cross-section under a microscope. However, since conservation practice and ethics limit sampling to a minimum and to areas along cracks and edges of paintings, which are often unrepresentative of the whole painting, results from such analyses cannot be taken as representative of a painting as a whole. Recently in a preliminary study, we have demonstrated that near-infrared Optical Coherence Tomography (OCT) can be used directly on paintings to examine the cross-section of paint and varnish layers without contact and the need to take samples. OCT is an optical interferometric technique developed for in vivo imaging of the eye and biological tissues; it is essentially a scanning Michelson’s interferometer with a ‘broadband’ source that has the spatial coherence of a laser. The low temporal coherence and high spatial concentration of the source are the keys to high depth resolution and high sensitivity 3D imaging. The technique is non-invasive and noncontact with a typical working distance of 2 cm. This non-invasive technique enables cross-sections to be examined anywhere on a painting. In this paper, we will report new results on applying near-infrared en-face OCT to paintings conservation and extend the application to the examination of underdrawings, drying processes, and quantitative measurements of optical properties of paint and varnish layers
In Vitro Propagation of Angiopteris Evecta Using Spores
Techniques of establishing Angiopleris evecta plants in vitro were studied. Soaking of A. evecta spores in water for 24 hours markedly reduced spore contamination. Soaking of the spores in 1 -2 % of sodium hypochlorite for less than 5 minutes allowed satisfactory disinfestation without affecting spore viability. Lower concentration of minerals (1/4 MS), presence of charcoal in the medium and exposure of the spores to light were crucial for spore germination and gainetophytc development of A. evecta
Classical and revisionary theism on the divine as personal: a rapprochement?
To claim that the divine is a person or personal is, according to Richard Swinburne, ‘the most elementary claim of theism’ (1993, 101). I argue that, whether the classical theist’s concept of the divine as a person or personal is construed as an analogy or a metaphor, or a combination of the two, analysis necessitates qualification of that concept such that any differences between the classical theist’s concept of the divine as a person or personal and revisionary interpretations of that concept are merely superficial. Thus, either the classical theist has more in common with revisionary theism than he/she might care to admit, or classical theism is a multi-faceted position which encompasses interpretations which some might regard as revisionist.
This article also explores and employs the use of a gender-neutral pronoun in talk about God
Advances in multispectral and hyperspectral imaging for archaeology and art conservation
Multispectral imaging has been applied to the field of art conservation and art history since the early 1990s. It is attractive as a noninvasive imaging technique because it is fast and hence capable of imaging large areas of an object giving both spatial and spectral information. This paper gives an overview of the different instrumental designs, image processing techniques and various applications of multispectral and hyperspectral imaging to art conservation, art history and archaeology. Recent advances in the development of remote and versatile multispectral and hyperspectral imaging as well as techniques in pigment identification will be presented. Future prospects including combination of spectral imaging with other noninvasive imaging and analytical techniques will be discussed
Cumulative Prognostic Score Predicting Mortality in Patients Older Than 80 Years Admitted to the ICU.
OBJECTIVES: To develop a scoring system model that predicts mortality within 30 days of admission of patients older than 80 years admitted to intensive care units (ICUs). DESIGN: Prospective cohort study. SETTING: A total of 306 ICUs from 24 European countries. PARTICIPANTS: Older adults admitted to European ICUs (N = 3730; median age = 84 years [interquartile range = 81-87 y]; 51.8% male). MEASUREMENTS: Overall, 24 variables available during ICU admission were included as potential predictive variables. Multivariable logistic regression was used to identify independent predictors of 30-day mortality. Model sensitivity, specificity, and accuracy were evaluated with receiver operating characteristic curves. RESULTS: The 30-day-mortality was 1562 (41.9%). In multivariable analysis, these variables were selected as independent predictors of mortality: age, sex, ICU admission diagnosis, Clinical Frailty Scale, Sequential Organ Failure Score, invasive mechanical ventilation, and renal replacement therapy. The discrimination, accuracy, and calibration of the model were good: the area under the curve for a score of 10 or higher was .80, and the Brier score was .18. At a cut point of 10 or higher (75% of all patients), the model predicts 30-day mortality in 91.1% of all patients who die. CONCLUSION: A predictive model of cumulative events predicts 30-day mortality in patients older than 80 years admitted to ICUs. Future studies should include other potential predictor variables including functional status, presence of advance care plans, and assessment of each patient's decision-making capacity
- …
