1,048 research outputs found
Theory of the c-Axis Penetration Depth in the Cuprates
Recent measurements of the London penetration depth tensor in the cuprates
find a weak temperature dependence along the c-direction which is seemingly
inconsistent with evidence for d-wave pairing deduced from in-plane
measurements. We demonstrate in this paper that these disparate results are not
in contradiction, but can be explained within a theory based on incoherent
quasiparticle hopping between the CuO2 layers. By relating the calculated
temperature dependence of the penetration depth \lambda_c(T) to the c-axis
resistivity, we show how the measured ratio \lambda_c^2(0) / \lambda_c^2(T) can
provide insight into the behavior of c-axis transport below Tc and the related
issue of ``confinement.''Comment: 4 pages, REVTEX with psfig, 3 PostScript figures included in
compressed for
Detection of minimal residual disease identifies differences in treatment response between T-ALL and precursor B-ALL
We performed sensitive polymerase chain reaction-based minimal residual
disease (MRD) analyses on bone marrow samples at 9 follow-up time points
in 71 children with T-lineage acute lymphoblastic leukemia (T-ALL) and
compared the results with the precursor B-lineage ALL (B-ALL) results (n =
210) of our previous study. At the first 5 follow-up time points, the
frequency of MRD-positive patients and the MRD levels were higher in T-ALL
than in precursor-B-ALL, reflecting the more frequent occurrence of
resistant disease in T-ALL. Subsequently, patients were classified
according to their MRD level at time point 1 (TP1), taken at the end of
induction treatment (5 weeks), and at TP2 just before the start of
consolidation treatment (3 months). Patients were considered at low risk
if TP1 and TP2 were MRD negative and at high risk if MRD levels at TP1 and
TP2 were 10(-3) or higher; remaining patients were considered at
intermediate risk. The relative distribution of patients with T-ALL (n =
43) over the MRD-based risk groups differed significantly from that of
precursor B-ALL (n = 109). Twenty-three percent of patients with T-ALL and
46% of patients with precursor B-ALL were classified in the low-risk group
(P =.01) and had a 5-year relapse-free survival (RFS) rate of 98% or
greater. In contrast, 28% of patients with T-ALL were classified in the
MRD-based high-risk group compared to only 11% of patients with precursor
B-ALL (P =.02), and the RFS rates were 0% and 25%, respectively (P =.03).
Not only was the distribution of patients with T-ALL different over the
MRD-based risk groups, the prognostic value of MRD levels at TP1 and TP2
was higher in T-ALL (larger RFS gradient), and consistently higher RFS
rates were found for MRD-negative T-ALL patients at the first 5 follow-up
time points
Recommended from our members
Effects of c-axis Josephson coupling on dissipation, flux dynamics and the mechanism of high-T{sub c} superconductivity
Measurements of the c-axis transport in highly anisotropic HTS materials strongly indicate that Josephson coupling is involved. This conclusion affects various properties of the HTS cuprates, including the irreversibility behavior for transport in the ab planes, the direct c-axis transport and potentially the mechanism of Cooper pairing
Frequency Characteristics of Visually Induced Motion Sickness
This article was published in the journal, Human Factors [Sage Publications / © Human Factors and Ergonomics Society.]. The definitive version is available at: http://dx.doi.org/10.1177/0018720812469046Objective: The aim of this study was to explore
the frequency response of visually induced motion
sickness (VIMS) for oscillating linear motion in the foreand-
aft axis.
Background: Simulators, virtual environments,
and commercially available video games that create an
illusion of self-motion are often reported to induce
the symptoms seen in response to true motion. Often
this human response can be the limiting factor in the
acceptability and usability of such systems. Whereas
motion sickness in physically moving environments
is known to peak at an oscillation frequency around
0.2 Hz, it has recently been suggested that VIMS peaks
at around 0.06 Hz following the proposal that the
summed response of the visual and vestibular selfmotion
systems is maximized at this frequency. Methods: We exposed 24 participants to random
dot optical flow patterns simulating oscillating foreand-
aft motion within the frequency range of 0.025 to
1.6 Hz. Before and after each 20-min exposure, VIMS was
assessed with the Simulator Sickness Questionnaire.
Also, a standard motion sickness scale was used to rate
symptoms at 1-min intervals during each trial.
Results: VIMS peaked between 0.2 and 0.4 Hz with
a reducing effect at lower and higher frequencies.
Conclusion: The numerical prediction of the
“crossover frequency” hypothesis, and the design
guidance curve previously proposed, cannot be accepted
when the symptoms are purely visually induced.
Application: In conditions in which stationary
observers are exposed to optical flow that simulates
oscillating fore-and-aft motion, frequencies around 0.2
to 0.4 Hz should be avoided
Guide for Identifying and Converting High-Potential Petroleum Brownfield Sites to Alternative Fuel Stations
Former gasoline stations that are now classified as brownfields can be good sites to sell alternative fuels because they are in locations that are convenient to vehicles and they may be seeking a new source of income. However, their success as alternative fueling stations is highly dependent on location-specific criteria. First, this report outlines what these criteria are, how to prioritize them, and then applies that assessment framework to five of the most popular alternative fuels--electricity, natural gas, hydrogen, ethanol, and biodiesel. The second part of this report delves into the criteria and tools used to assess an alternative fuel retail site at the local level. It does this through two case studies of converting former gasoline stations in the Seattle-Eugene area into electric charge stations. The third part of this report addresses steps to be taken after the specific site has been selected. This includes choosing and installing the recharging equipment, which includes steps to take in the permitting process and key players to include
Recommended from our members
Effects of vortex-vortex interactions on ion-track pinning in high T{sub c} superconductors
Many superconductor applications rely on the ability to pin vortex lattices. This ability depends on structural defects to pin individual vortices, but vortex-vortex interactions often play an important role in pinning the other vortices. Experimental progress on this complex problem can be made by introducing random arrays of well-defined pinning centers and studying the flux dynamics for a range of vortex densities (i.e., fields). Results of such studies in epitaxial Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub y} films containing ion tracks show the importance of vortex-vortex interactions. As an example, the effective pinning field of the defects rises to many times the ion-dose field for temperatures well below {Tc}
Safety of Silver Oxide Coated Biomaterials in Mice
It has been demonstrated that silver oxide coatings designed by our collaborators are able to prevent E. coli and P. aeruginosa attachment to biomaterials in vivo. These findings demonstrate that such coatings show promise in preventing the development of biofilm on biodevices. However, it is unknown if the use of silver oxide in this fashion is toxic in vivo. The goal of this project was to determine whether our silver oxide coatings are safe to use in vivo. To assess the toxicity of our silver oxide formula, mice were implanted with either silver oxide coated titanium discs or uncoated titanium discs. Blood samples were drawn at pre-determined time points in order to determine AST and ALT levels via ELISA assay. Preliminary results demonstrate no acute liver injury after 3 months with the discs. However, it appears as if silver is accumulating in tissues over time. Histological analysis at one year shows evidence of simple steatosis in livers. While our group is continuing to investigate the safety and efficacy of these silver oxides coatings in vivo, preliminary data shows that they may have some toxicity and the silver oxide formula may need to be altered and retested
Adenosine A2A receptors: localization and function
Adenosine is an endogenous purine nucleoside present in all mammalian tissues, that originates from the breakdown of ATP. By binding to its four receptor subtypes (A1, A2A, A2B, and A3), adenosine regulates several important physiological functions at both the central and peripheral levels. Therefore, ligands for the different adenosine receptors are attracting increasing attention as new potential drugs to be used in the treatment of several diseases. This chapter is aimed at providing an overview of adenosine metabolism, adenosine receptors localization and their signal transduction pathways. Particular attention will be paid to the biochemistry and pharmacology of A2A receptors, since antagonists of these receptors have emerged as promising new drugs for the treatment of Parkinson's disease. The interactions of A2A receptors with other nonadenosinergic receptors, and the effects of the pharmacological manipulation of A2A receptors on different body organs will be discussed, together with the usefulness of A2A receptor antagonists for the treatment of Parkinson's disease and the potential adverse effects of these drugs
Electrochemical Oxidation of Metal Carbides in Aqueous Solutions
Transition metal carbides have unique properties such as high hardness, high melting temperatures, high thermal conductivity, and high chemical stability. In this report, we investigate the electrochemical oxidation of a series of metal carbides including NbC, Nb2C, TaC, Ta2C, VC, VCrC, TiC and TiCrC in neutral, basic, or acidic aqueous solutions. Cyclic voltammetry and elemental analysis demonstrated that many of these metal carbides can be electrochemically oxidized at low electrode potentials to produce soluble metal ions in the solutions. Carbon in the metal carbides remains on the electrode substrates and forms porous carbide-derived carbon (CDC). The surface morphology of the CDC and specific surface area depend on the metal carbide precursors and the electrochemical oxidation conditions
- …
