913 research outputs found
Reinforced oxide throat insert development
Wire reinforced zirconium oxide rocket nozzle insert
Prevalence and correlates of achieving recommended physical activity levels among children living in rural South Asia—A multi-centre study
Background: We report the prevalence of recommended physical activity levels (RPALs) and examine the correlates of achieving RPALs in rural South Asian children and analyse its association with anthropometric outcomes. Methods: This analysis on rural South Asian children aged 5–14 years (n = 564) is a part of the Chronic Disease Risk Factor study conducted at three sites in India (Chennai n = 146; Goa n = 218) and Bangladesh (Matlab; n = 200). Data on socio-demographic and lifestyle factors (physical activity (PA); diet) were collected using an interviewer-administered questionnaires, along with objective anthropometric measurements. Multivariate logistic regression models were used to examine whether RPALs (active travel to school (yes/no); leisure-time PA ≥ 1 h/day; sedentary-activity ≤ 2 h/day) were associated with socio-demographic factors, diet and other forms of PA. Multivariate linear regression models were used to investigate associations between RPALs and anthropometrics (BMI- and waist z-scores). Results: The majority of children (71.8 %) belonged to households where a parent had at least a secondary education. Two-thirds (66.7 %) actively travelled to school; 74.6 % reported ≥1 h/day of leisure-time PA and 55.7 % had ≤2 h/day of sedentary-activity; 25.2 % of children reported RPALs in all three dimensions. Older (10–14 years, OR = 2.0; 95 % CI: 1.3, 3.0) and female (OR = 1.7; 95 % CI: 1.1, 2.5) children were more likely to travel actively to school. Leisure-time PA ≥ 1 h/day was more common among boys (OR = 2.5; 95 % CI: 1.5, 4.0), children in Matlab, Bangladesh (OR = 3.0; 95 % CI: 1.6, 5.5), and those with higher processed-food consumption (OR = 2.3; 95 % CI: 1.2, 4.1). Sedentary activity ≤ 2 h/day was associated with younger children (5–9 years, OR = 1.6; 95 % CI: 1.1, 2. 4), children of Goa (OR = 3.5; 95 % CI: 2.1, 6.1) and Chennai (OR = 2.5; 95 % CI: 1.5, 4.3) and low household education (OR = 2.1; 95 % CI: 1.1, 4.1). In multivariate analyses, sedentary activity ≤ 2 h/day was associated with lower BMI-z-scores (β = −0.3; 95 % CI: −0.5, −0.08) and lower waist-z-scores (β = −1.1; 95 % CI: −2.2, −0.07). Conclusion: Only one quarter of children in these rural areas achieved RPAL in active travel, leisure and sedentary activity. Improved understanding of RPAL in rural South Asian children is important due to rapid socio-economic transition
Developing the Next Generation of Physics Assessments
Science education at all levels is currently undergoing dramatic changes to
its curricula and developing assessments for these new curricula is paramount.
We have used the basis of many of these new changes (scientific practices,
crosscutting concepts, and core ideas) to develop sets of criteria that can be
used to guide assessment development for this new curriculum. We present a case
study that uses the criteria we have developed to revise a traditional physics
assessment item into an assessment item that is much more aligned with the
goals of current transformation efforts. Assessment items developed using this
criteria can be used to assess student learning of both the concepts and
process of science.Comment: Revised version for PERC 2015 Conference Proceeding
Loss-of-Mains Protection System by Application of Phasor Measurement Unit Technology with Experimentally Assessed Threshold Settings
Loss-of-mains protection is an important component of the protection systems of embedded generation. The role of loss-of-mains is to disconnect the embedded generator from the utility grid in the event that connection to utility dispatched generation is lost. This is necessary for a number of reasons, including the safety of personnel during fault restoration and the protection of plant against out-of-synchronism reclosure to the mains supply. The incumbent methods of loss-of-mains protection were designed when the installed capacity of embedded generation was low, and known problems with nuisance tripping of the devices were considered acceptable because of the insignificant consequence to system operation. With the dramatic increase in the installed capacity of embedded generation over the last decade, the limitations of current islanding detection methods are no longer acceptable. This study describes a new method of loss-of-mains protection based on phasor measurement unit (PMU) technology, specifically using a low cost PMU device of the authors' design which has been developed for distribution network applications. The proposed method addresses the limitations of the incumbent methods, providing a solution that is free of nuisance tripping and has a zero non-detection zone. This system has been tested experimentally and is shown to be practical, feasible and effective. Threshold settings for the new method are recommended based on data acquired from both the Great Britain and Ireland power systems
Impact of a COPD Discharge Care Bundle on Readmissions following Admission with Acute Exacerbation: Interrupted Time Series Analysis.
We evaluated the impact of a COPD discharge care bundle on readmission rates following hospitalisation with an acute exacerbation.Interrupted time series analysis, comparing readmission rates for COPD exacerbations at nine trusts that introduced the bundle, to two comparison groups; (1) other NHS trusts in London and (2) all other NHS trusts in England. Care bundles were implemented at different times for different NHS trusts, ranging from October 2009 to April 2011.Nine NHS acute trusts in the London, England.Patients aged 45 years and older admitted to an NHS acute hospital in England for acute exacerbation of COPD. Data come from Hospital Episode Statistics, April 2002 to March 2012.Annual trend readmission rates (and in total bed days) within 7, 28 and 90 days, before and after implementation.In hospitals introducing the bundle readmission rates were rising before implementation and falling afterwards (e.g. readmissions within 28 days +2.13% per annum (pa) pre and -5.32% pa post (p for difference in trends = 0.012)). Following implementation, readmission rates within 7 and 28 day were falling faster than among other trusts in London, although this was not statistically significant (e.g. readmissions within 28 days -4.6% pa vs. -3.2% pa, p = 0.44). Comparisons with a national control group were similar.The COPD discharge care bundle appeared to be associated with a reduction in readmission rate among hospitals using it. The significance of this is unclear because of changes to background trends in London and nationally
The OpenPMU Platform for Open Source Phasor Measurements
OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. This paper presents the OpenPMU device based on the Labview development environment. The device is performance tested according to the IEEE C37.118.1 standard. Compatibility with the IEEE C37.118.2 messaging format is achieved through middleware which is readily adaptable to other PMU projects or applications. Improvements have been made to the original design to increase its flexibility. A new modularized architecture for the OpenPMU is presented using an open messaging format which the authors propose is adopted as a platform for PMU research.</p
Principal Component Analysis of Wide Area Phasor Measurements for Islanding Detection – A Geometric View
This paper presents a new technique for the detectionof islanding conditions in electrical power systems. This problem isespecially prevalent in systems with significant penetrations of distributedrenewable generation. The proposed technique is based onthe application of principal component analysis (PCA) to data setsof wide-area frequency measurements, recorded by phasor measurementunits. The PCA approach was able to detect islandingaccurately and quickly when compared with conventional RoCoFtechniques, as well as with the frequency difference and change-ofangledifference methods recently proposed in the literature. Thereliability and accuracy of the proposed PCA approach is demonstratedby using a number of test cases, which consider islandingand nonislanding events. The test cases are based on real data,recorded from several phasor measurement units located in theU.K. power system
Antimicrobial Efficacy of an Innovative Emulsion of Medium Chain Triglycerides against Canine and Feline Periodontopathogens
- …