1,482 research outputs found
Accurate mass measurements of Ne, Na, Mg performed with the {\sc Mistral} spectrometer
The minuteness of the nuclear binding energy requires that mass measurements
be highly precise and accurate. Here we report on new measurements Mg
and Na performed with the {\sc Mistral} mass spectrometer at {\sc
Cern}'s {\sc Isolde} facility. Since mass measurements are prone to systematic
errors, considerable effort has been devoted to their evaluation and
elimination in order to achieve accuracy and not only precision. We have
therefore conducted a campaign of measurements for calibration and error
evaluation. As a result, we now have a satisfactory description of the {\sc
Mistral} calibration laws and error budget. We have applied our new
understanding to previous measurements of Ne, Na and
Mg for which re-evaluated values are reported.Comment: submitted to Nuclear Physics
National Space Transportation Systems Program mission report
The STS 41-C National Space Transportation Systems Program Mission Report contains a summary of the major activities and accomplishments of the eleventh Shuttle flight and fifth flight of the OV-099 vehicle, Challenger. Also summarized are the significant problems that occurred during STS 41-C, and a problem tracking list that is a complete list of all problems that occurred during the flight. The major objectives of flight STS 41-C were to successfully deploy the LDEF (long duration exposure facility) and retrieve, repair and redeploy the SMM (Solar Maximum Mission) spacecraft, and perform functions of IMAX and Cinema 360 cameras
A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams
An ion beam cooler and buncher has been developed for the manipulation of
radioactive ion beams. The gas-filled linear radiofrequency ion trap system is
installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its
purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high
efficiency and to convert it into low-energy low-emittance ion pulses. The
efficiency was found to exceed 10% in agreement with simulations. A more than
10-fold reduction of the ISOLDE beam emittance can be achieved. The system has
been used successfully for first on-line experiments. Its principle, setup and
performance will be discussed
Q-Value and Half-Lives for the Double-Beta-Decay Nuclide 110Pd
The 110Pd double-beta decay Q-value was measured with the Penning-trap mass
spectrometer ISOLTRAP to be Q = 2017.85(64) keV. This value shifted by 14 keV
compared to the literature value and is 17 times more precise, resulting in new
phase-space factors for the two-neutrino and neutrinoless decay modes. In
addition a new set of the relevant matrix elements has been calculated. The
expected half-life of the two-neutrino mode was reevaluated as 1.5(6) E20 yr.
With its high natural abundance, the new results reveal 110Pd to be an
excellent candidate for double-beta decay studies
First direct mass-measurement of the two-neutron halo nucleus 6He and improved mass for the four-neutron halo 8He
The first direct mass-measurement of He has been performed with the
TITAN Penning trap mass spectrometer at the ISAC facility. In addition, the
mass of He was determined with improved precision over our previous
measurement. The obtained masses are (He) = 6.018 885 883(57) u and
(He) = 8.033 934 44(11) u. The He value shows a deviation from
the literature of 4. With these new mass values and the previously
measured atomic isotope shifts we obtain charge radii of 2.060(8) fm and
1.959(16) fm for He and He respectively. We present a detailed
comparison to nuclear theory for He, including new hyperspherical harmonics
results. A correlation plot of the point-proton radius with the two-neutron
separation energy demonstrates clearly the importance of three-nucleon forces.Comment: 4 pages, 2 figure
Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements
A new technique has been developed at TRIUMF's TITAN facility to perform
in-trap decay spectroscopy. The aim of this technique is to eventually measure
weak electron capture branching ratios (ECBRs) and by this to consequently
determine GT matrix elements of decaying nuclei. These branching
ratios provide important input to the theoretical description of these decays.
The feasibility and power of the technique is demonstrated by measuring the
ECBR of Cs.Comment: 9 pages, 9 figure
Probing the N = 32 shell closure below the magic proton number Z = 20: Mass measurements of the exotic isotopes 52,53K
The recently confirmed neutron-shell closure at N = 32 has been investigated
for the first time below the magic proton number Z = 20 with mass measurements
of the exotic isotopes 52,53K, the latter being the shortest-lived nuclide
investigated at the online mass spectrometer ISOLTRAP. The resulting
two-neutron separation energies reveal a 3 MeV shell gap at N = 32, slightly
lower than for 52Ca, highlighting the doubly-magic nature of this nuclide.
Skyrme-Hartree-Fock-Boguliubov and ab initio Gorkov-Green function calculations
are challenged by the new measurements but reproduce qualitatively the observed
shell effect.Comment: 5 pages, 5 figure
Evidence for a breakdown of the Isobaric Multiplet Mass Equation: A study of the A=35, T=3/2 isospin quartet
Mass measurements on radionuclides along the potassium isotope chain have
been performed with the ISOLTRAP Penning trap mass spectrometer. For 35K
T1/2=178ms) to 46K (T1/2=105s) relative mass uncertainties of 2x10-8 and better
have been achieved. The accurate mass determination of 35K (dm=0.54keV) has
been exploited to test the Isobaric Multiplet Mass Equation (IMME) for the
A=35, T=3/2 isospinquartet. The experimental results indicate a deviation from
the generally adopted quadratic form.Comment: 8 pages, 4 figure
- …