1,772 research outputs found
Recommended from our members
Improving Visual Field Examination of the Macula Using Structural Information
Purpose: To investigate a novel approach for structure-function modeling in glaucoma to improve visual field testing in the macula.
Methods: We acquired data from the macular region in 20 healthy eyes and 31 with central glaucomatous damage. Optical coherence tomography (OCT) scans were used to estimate the local macular ganglion cell density. Perimetry was performed with a fundus-tracking device using a 10-2 grid. OCT scans were matched to the retinal image from the fundus perimeter to accurately map the tested locations onto the structural damage. Binary responses from the subjects to all presented stimuli were used to calculate the structure-function model used to generate prior distributions for a ZEST (Zippy Estimation by Sequential Testing) Bayesian strategy. We used simulations based on structural and functional data acquired from an independent dataset of 20 glaucoma patients to compare the performance of this new strategy, structural macular ZEST (MacS-ZEST), with a standard ZEST.
Results: Compared to the standard ZEST, MacS-ZEST reduced the number of presentations by 13% in reliable simulated subjects and 14% with higher rates (≥20%) of false positive or false negative errors. Reduction in mean absolute error was not present for reliable subjects but was gradually more important with unreliable responses (≥10% at 30% error rate).
Conclusions: Binary responses can be modeled to incorporate detailed structural information from macular OCT into visual field testing, improving overall speed and accuracy in poor responders.
Translational Relevance: Structural information can improve speed and reliability for macular testing in glaucoma practice
Recommended from our members
Optical Coherence Tomography Angiography of Iris Nevus: A Case Report
Iris nevus is common: 6% of patients with suspected iris melanoma have lesions other than melanoma, and 36% of them are nevi. Iris nevus turns into melanoma in approximately 8% of cases at a mean of 15 years. This case report provides the first description of an iris tumor examined with iris optical coherence tomography angiography (OCTA) compared to iris fluorescein angiography (IFA). A 60-year-old man with a diagnosis of iris nevus in the left eye was referred to our department for IFA and iris OCTA. The iris vasculature in IFA was visible only in the early phases, but not clearly. OCTA, however, gave visualization of the vascular network and very precisely defined the vessels of the whole lesion, except for the pupillary portion, which was masked by superficial pigment accumulations. IFA and iris OCTA can add information about the vascular architecture compared to slit-lamp biomicroscopy, ultrasound biomicroscopy, and anterior-segment OCT. However, IFA is time-consuming and invasive and can – very occasionally – cause serious adverse reactions. In contrast, OCTA defines the texture of the iris vasculature better. In conclusion, OCTA is a new method, easy to execute, needing no dye injection, and provides useful information on the vascular network of iris lesions. It could therefore be helpful in the diagnosis and follow-up of these lesions
Recommended from our members
Effect of prophylactic timolol 0.1% gel on intraocular pressure after an intravitreal injection of ranibizumab: a randomized study
Purpose: The purpose of this study is to make a prospective evaluation of the effect of timolol 0.1% eye gel on short-term intraocular pressure (IOP) after an intravitreal injection (IVI) of ranibizumab.
Participants and methods: One hundred and fifty eyes of 150 IVI-naïve patients with macular edema caused by various pathological conditions (age-related macular degeneration, central or branch retinal vein occlusion, and diabetic retinopathy) were scheduled to undergo an IVI of ranibizumab (0.5 mg/0.05 cc). The patients were randomly divided into three groups: 50 were not treated with timolol before the IVI (group 1); 50 received an instillation of timolol 0.1% eye gel the evening before the IVI (group 2); and 50 received an instillation of timolol 0.1% eye gel 2 hours before the IVI (group 3). The incidence of clinically significant intraocular hypertensive spikes (>25 mmHg and >40 mmHg) was then assessed.
Results: Our findings showed that mean IOP at baseline was significantly higher than at both 5 and 60 minutes after IVI (P25 mmHg were recorded at either time in 27 patients (54%) in group 1, 23 patients (44%) in group 2, and 24 patients (48%) in group 3. None of the between-group differences were significant. Spikes of >40 mmHg (which were only detected 5 minutes after IVI) were recorded in nine (18%), eight (16%), and one patient (2%) in groups 1, 2, and 3, respectively. The only significant difference was between the control and group 3 (P=0.012).
Conclusion: An increase in IOP after antivascular endothelial growth factor IVI is a frequent complication. The prophylactic use of timolol 0.1% gel effectively reduced the mean IOP when administered 2 hours before IVI and was also effective in preventing dangerous IOP spikes of >40 mmHg. It is therefore recommended before IVIs as a means of preventing emergency procedures and preserving the health of the optic nerve
Recommended from our members
Improving perimetric examination of the macular visual field using structural information
Recommended from our members
Testing a phantom eye under various signal-to-noise ratio conditions using eleven different OCT devices
We compared eleven OCT devices in their ability to quantify retinal layer thicknesses under different signal-strength conditions, using a commercially available phantom eye. We analyzed a medium-intensity 50 µm layer in an identical manner for all devices, using the provided log-scale images and a reconstructed linear-scale tissue reflectivity metric. Thickness measurements were highly comparable when the data were analyzed in an identical manner. With optimal signal strength, the thickness of the 50 µm layer was overestimated by a mean of 4.3 µm in the log-scale images and of 2.7 µm in the linear-scale images
Experimental results of crystal-assisted slow extraction at the SPS
The possibility of extracting highly energetic particles from the Super
Proton Synchrotron (SPS) by means of silicon bent crystals has been explored
since the 1990's. The channelling effect of a bent crystal can be used to
strongly deflect primary protons and eject them from the synchrotron. Many
studies and experiments have been carried out to investigate crystal
channelling effects. The extraction of 120 and 270 GeV proton beams has already
been demonstrated in the SPS with dedicated experiments located in the ring.
Presently in the SPS, the UA9 experiment is performing studies to evaluate the
possibility to use bent silicon crystals to steer particle beams in high energy
accelerators. Recent studies on the feasibility of extraction from the SPS have
been made using the UA9 infrastructure with a longer-term view of using
crystals to help mitigate slow extraction induced activation of the SPS. In
this paper, the possibility to eject particles into the extraction channel in
LSS2 using the bent crystals already installed in the SPS is presented. Details
of the concept, simulations and measurements carried out with beam are
presented, before the outlook for the future is discussed.Comment: 4 pages, 7 figures, submitted to to International Particle
Accelerator Conference (IPAC) 2017 in Copenhagen, Denmar
Recommended from our members
Cataract and optic disk drusen in a patient with glycogenosis and di George syndrome: clinical and molecular report
Background
We report the ophthalmic findings of a patient with type Ia glycogen storage disease (GSD Ia), DiGeorge syndrome (DGS), cataract and optic nerve head drusen (ONHD).
Case presentation
A 26-year-old white woman, born at term by natural delivery presented with a post-natal diagnosis of GSD Ia. Genetic testing by array-comparative genomic hybridization (CGH) for DGS was required because of her low levels of serum calcium. The patient has been followed from birth, attending the day-hospital every six months at the San Paolo Hospital, Milan, outpatient clinic for metabolic diseases and previously at another eye center. During the last day-hospital visit, a complete eye examination showed ONHD and cataract in both eyes. Next Generation Sequencing (NGS) was subsequently done to check for any association between the eye problems and metabolic aspects.
Conclusions
This is the first description of ocular changes in a patient with GSD Ia and DGS. Mutations explaining GSD Ia and DGS were found but no specific causative mutation for cataract and ONHD. The metabolic etiology of her lens changes is known, whereas the pathogenesis of ONHD is not clear. Although the presence of cataract and ONHD could be a coincidence; the case reported could suggest that hypocalcemia due to DGS could be the common biochemical pathway
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
The UA9 Experiment at CERN-SPS investigates channeling processes in bent
silicon crystals with the aim to manipulate hadron beams. Monitoring and
characterization of channeled beams in the high energy accelerators environment
ideally requires in-vacuum and radiation hard detectors. For this purpose the
Cherenkov detector for proton Flux Measurement (CpFM) was designed and
developed. It is based on thin fused silica bars in the beam pipe vacuum which
intercept charged particles and generate Cherenkov light. The first version of
the CpFM is installed since 2015 in the crystal-assisted collimation setup of
the UA9 experiment. In this paper the procedures to make the detector
operational and fully integrated in the UA9 setup are described. The most
important standard operations of the detector are presented. They have been
used to commission and characterize the detector, providing moreover the
measurement of the integrated channeled beam profile and several functionality
tests as the determination of the crystal bending angle.
The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and
the results are applied to the flux measurement discussed here in detail.Comment: 25 pages, 14 figure
Cognitive conflicts in major depression : Between desired change and personal coherence
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposesThe notion of intrapsychic conflict has been present in psychopathology for more than a century within different theoretical orientations. However, internal conflicts have not received enough empirical attention, nor has their importance in depression been fully elaborated. This study is based on the notion of cognitive conflict, understood as implicative dilemma (ID), and on a new way of identifying these conflicts by means of the Repertory Grid Technique. Our aim was to explore the relevance of cognitive conflicts among depressive patientsPeer reviewedFinal Published versio
Preliminary Validation of the AFWA-NASA Blended Snowcover Product Over the Lower Great Lakes region
A new snow product created using the standard Moderate-Resolution Imaging Spectroradiometer (MODIS) and Advanced Microwave Scanning Radiometer for EOS (AMSR-E) snow cover and snow-water equivalent products has been evaluated for the Lower Great Lakes region during the winter of 2002- 03. National Weather Service Co-Operative Observing Network stations and student-acquired snow data were used as ground truth. An interpolation scheme was used to map snow cover on the ground from the station measurements for each day of the study period. It is concluded that this technique does not represent the actual ground conditions adequately to permit evaluation of the new snow product in an absolute sense. However, use of the new product was found to improve the mapping of snow cover as compared to using either the MODIS or AMSR-E product, alone. Plans for further analysis are discussed
- …
