2,075 research outputs found
A 4-D dataset for validation of crystal growth in a complex three-phase material, ice cream
Four dimensional (4D, or 3D plus time) X-ray tomographic imaging of phase changes in materials is quickly becoming an accepted tool for quantifying the development of microstructures to both inform and validate models. However, most of the systems studied have been relatively simple binary compositions with only two phases. In this study we present a quantitative dataset of the phase evolution in a complex three-phase material, ice cream. The microstructure of ice cream is an important parameter in terms of sensorial perception, and therefore quantification and modelling of the evolution of the microstructure with time and temperature is key to understanding its fabrication and storage. The microstructure consists of three phases, air cells, ice crystals, and unfrozen matrix. We perform in situ synchrotron X-ray imaging of ice cream samples using in-line phase contrast tomography, housed within a purpose built cold-stage (-40 to +20oC) with finely controlled variation in specimen temperature. The size and distribution of ice crystals and air cells during programmed temperature cycling are determined using 3D quantification. The microstructural evolution of three-phase materials has many other important applications ranging from biological to structural and functional material, hence this dataset can act as a validation case for numerical investigations on faceted and non-faceted crystal growth in a range of materials
Recommended from our members
Anatomic Fat Depots and Coronary Plaque Among Human Immunodeficiency Virus-Infected and Uninfected Men in the Multicenter AIDS Cohort Study.
Methods. In a cross-sectional substudy of the Multicenter AIDS Cohort Study, noncontrast cardiac computed tomography (CT) scanning for coronary artery calcium (CAC) scoring was performed on all men, and, for men with normal renal function, coronary CT angiography (CTA) was performed. Associations between fat depots (visceral adipose tissue [VAT], abdominal subcutaneous adipose tissue [aSAT], and thigh subcutaneous adipose tissue [tSAT]) with coronary plaque presence and extent were assessed with logistic and linear regression adjusted for age, race, cardiovascular disease (CVD) risk factors, body mass index (BMI), and human immunodeficiency virus (HIV) parameters. Results. Among HIV-infected men (n = 597) but not HIV-uninfected men (n = 343), having greater VAT was positively associated with noncalcified plaque presence (odds ratio [OR] = 1.04, P < .05), with a significant interaction (P < .05) by HIV serostatus. Human immunodeficiency virus-infected men had lower median aSAT and tSAT and greater median VAT among men with BMI <25 and 25-29.9 kg/m(2). Among HIV-infected men, VAT was positively associated with presence of coronary plaque on CTA after adjustment for CVD risk factors (OR = 1.04, P < .05), but not after additional adjustment for BMI. There was an inverse association between aSAT and extent of total plaque among HIV-infected men, but not among HIV-uninfected men. Lower tSAT was associated with greater CAC and total plaque score extent regardless of HIV serostatus. Conclusions. The presence of greater amounts of VAT and lower SAT may contribute to increased risk for coronary artery disease among HIV-infected persons
Location of the Energy Levels of the Rare-Earth Ion in BaF2 and CdF2
The location of the energy levels of rare-earth (RE) elements in the energy
band diagram of BaF2 and CdF2 crystals is determined. The role of RE3+ and RE2+
ions in the capture of charge carriers, luminescence, and the formation of
radiation defects is evaluated. It is shown that the substantial difference in
the luminescence properties of BaF2:RE and CdF2:RE is associated with the
location of the excited energy levels in the band diagram of the crystals
On parton distributions in a photon gas
In some cases it may be useful to know parton distributions in a photon gas.
This may be relevant, e.g., for the analysis of interactions of high energy
cosmic ray particles with the cosmic microwave background radiation. The latter
can be considered as a gas of photons with an almost perfect blackbody
spectrum. An approach to finding such parton distributions is described. The
survival probability of ultra-high energy neutrinos traveling through this
radiation is calculated.Comment: 5 pages, 4 figures, EPJ style files. Some changes in the text. Two
new sections discussing ultra-high energy neutrino damping in the cosmic
microwave background radiation are include
Perceptions Of School By Two Teenage Boys With Asperger Syndrome And Their Mothers: A Qualitative Study
This qualitative study aimed to develop an understanding of the challenges faced by teenage boys with Asperger syndrome and their mothers. A case study approach was used to collect data from two 13-year-old boys who have Asperger syndrome and their mothers in Queensland, Australia. Data were collected through the use of semi¬structured interviews. The words of the boys and their mothers provide a valuable insight into the personal experiences and feelings of the par¬ticipants. An inductive approach to data analysis identified four themes: (1) developmental differences; (2) problems associated with the general characteristics of Asperger syndrome (i.e. communication and social difficulties, restricted range of interests, a need for routine); (3) stress; and (4) 'masquerading'. The first three themes relate strongly to the current literature, but the emergence of masquerading is of particular interest in developing a fuller understanding of the experiences of individuals with Asperger syndrome at school
Nonet Symmetry and Two-Body Decays of Charmed Mesons
The decay of charmed mesons into pseudoscalar (P) and vector (V) mesons is
studied in the context of nonet symmetry. We have found that it is badly broken
in the PP channels and in the P sector of the PV channels as expected from the
non-ideal mixing of the \eta and the \eta'. In the VV channels, it is also
found that nonet symmetry does not describe the data well. We have found that
this discrepancy cannot be attributed entirely to SU(3) breaking at the usual
level of 20--30%. At least one, or both, of nonet and SU(3) symmetry must be
very badly broken. The possibility of resolving the problem in the future is
also discussed.Comment: 9 pages, UTAPHY-HEP-
Neoliberalisation and 'lad cultures' in higher education
This paper links HE neoliberalisation and ‘lad cultures’, drawing on interviews and focus groups with women students. We argue that retro-sexist ‘laddish’ forms of masculine competitiveness and misogyny have been reshaped by neoliberal rationalities to become modes of consumerist sexualised audit. We also suggest that neoliberal frameworks scaffold an individualistic and adversarial culture among young people that interacts with perceived threats to men’s privilege and intensifies attempts to put women in their place through misogyny and sexual harassment. Furthermore, ‘lad cultures’, sexism and sexual harassment in higher education may be invisibilised by institutions to preserve marketability in a neoliberal context. In response, we ask if we might foster dialogue and partnership between feminist and anti-marketisation politics
Carbon Nanotubes by a CVD Method. Part II: Formation of Nanotubes from (Mg, Fe)O Catalysts
The aim of this paper is to study the formation of carbon nanotubes (CNTs) from different Fe/MgO oxide powders that were prepared by combustion synthesis and characterized in detail in a companion paper. Depending on the synthesis conditions, several iron species are present in the starting oxides including Fe2+ ions, octahedral Fe3+ ions, Fe3+ clusters, and MgFe2O4-like nanoparticles. Upon reduction during heating at 5 °C/min up to 1000 °C in H2/CH4 of the oxide powders, the octahedral Fe3+ ions tend to form Fe2+ ions, which are not likely to be reduced to metallic iron whereas the MgFe2O4-like particles are directly reduced to metallic iron. The reduced phases are R-Fe, Fe3C, and ç-Fe-C. Fe3C appears as the postreaction phase involved in the formation of carbon filaments (CNTs and thick carbon nanofibers). Thick carbon nanofibers are formed from catalyst particles originating from poorly dispersed species (Fe3+ clusters and MgFe2O4-like particles). The nanofiber outer diameter is determined by the particle size. The reduction of the iron ions and clusters that are well dispersed in the MgO lattice leads to small catalytic particles (<5 nm), which tend to form SWNTS and DWNTs with an inner diameter close to 2 nm. Well-dispersed MgFe2O4-like particles can also be reduced to small metal particles with a narrow size distribution, producing SWNTs and DWNTs. The present results will help in tailoring oxide precursors for the controlled formation of CNTs
Validity of the Polar V800 heart rate monitor to measure RR intervals at rest
Purpose To assess the validity of RR intervals and short-term heart rate variability (HRV) data obtained from the Polar V800 heart rate monitor, in comparison to an electrocardiograph (ECG). Method Twenty participants completed an active orthostatic test using the V800 and ECG. An improved method for the identification and correction of RR intervals was employed prior to HRV analysis. Agreement of the data was assessed using intra-class correlation coefficients (ICC), Bland–Altman limits of agreement (LoA), and effect size (ES). Results A small number of errors were detected between ECG and Polar RR signal, with a combined error rate of 0.086 %. The RR intervals from ECG to V800 were significantly different, but with small ES for both supine corrected and standing corrected data (ES 0.999 for both supine and standing corrected intervals. When analysed with the same HRV software no significant differences were observed in any HRV parameters, for either supine or standing; the data displayed small bias and tight LoA, strong ICC (>0.99) and small ES (≤0.029). Conclusions The V800 improves over previous Polar models, with narrower LoA, stronger ICC and smaller ES for both the RR intervals and HRV parameters. The findings support the validity of the Polar V800 and its ability to produce RR interval recordings consistent with an ECG. In addition, HRV parameters derived from these recordings are also highly comparable
- …
