48,598 research outputs found

    Modified algesimeter provides accurate depth measurements

    Get PDF
    Algesimeter which incorporates a standard sensory needle with a sensitive micrometer, measures needle point depth penetration in pain tolerance research. This algesimeter provides an inexpensive, precise instrument with assured validity of recordings in those biomedical areas with a requirement for repeated pain detection or ascertaining pain sensitivity

    Continuously observing a dynamically decoupled spin-1 quantum gas

    Get PDF
    We continuously observe dynamical decoupling in a spin-1 quantum gas using a weak optical measurement of spin precession. Continuous dynamical decoupling aims to dramatically modify the character and energy spectrum of spin states to render them insensitive to parasitic fluctuations. Continuous observation measures this new spectrum in a single-preparation of the quantum gas. The measured time-series contains seven tones, which spectrogram analysis parses as splittings, coherences, and coupling strengths between the decoupled states in real-time. With this we locate a regime where a transition between two states is decoupled from magnetic field instabilities up to fourth order, complementary to the parallel work at higher fields by Trypogeorgos et al. (arXiv:1706.07876). The decoupled microscale quantum gas offers magnetic sensitivity in a tunable band, persistent over many milliseconds: the length scales, frequencies, and durations relevant to many applications, including sensing biomagnetic phenomena such as neural spike trains.Comment: 5+ pages, 4 figures, 1 table; revised citation of Trypogeorgos et al. (2017

    Suspending test masses in terrestrial millihertz gravitational-wave detectors: a case study with a magnetic assisted torsion pendulum

    Full text link
    Current terrestrial gravitational-wave detectors operate at frequencies above 10 Hz. There is strong astrophysical motivation to construct low-frequency gravitational-wave detectors capable of observing 10 mHz - 10Hz signals. While space-based detectors provide one means of achieving this end, one may also consider terretrial detectors. However, there are numerous technological challenges. In particular, it is difficult to isolate test masses so that they are both seismically isolated and freely falling under the influence of gravity at millihertz frequencies. We investigate the challenges of low-frequency suspension in a hypothetical terrestrial detector. As a case study, we consider a Magnetically Assisted Gravitational-wave Pendulum Intorsion (MAGPI) suspension design. We construct a noise budget to estimate some of the required specifications. In doing so, we identify what are likely to be a number of generic limiting noise sources for terrestrial millihertz gravitational-wave suspension systems (as well as some peculiar to the MAGPI design). We highlight significant experimental challenges in order to argue that the development of millihertz suspensions will be a daunting task. Any system that relies on magnets faces even greater challenges. Entirely mechanical designs such as Zollner pendulums may provide the best path forward.Comment: 6 pages, 4 figure

    Scalar Field as Dark Matter in the Universe

    Get PDF
    We investigate the hypothesis that the scalar field is the dark matter and the dark energy in the Cosmos, wich comprises about 95% of the matter of the Universe. We show that this hypothesis explains quite well the recent observations on type Ia supernovae.Comment: 4 pages REVTeX, 1 eps figure. Minor changes. To appear in Classical and Quantum Gravit

    An order (n) algorithm for the dynamics simulation of robotic systems

    Get PDF
    The formulation of an Order (n) algorithm for DISCOS (Dynamics Interaction Simulation of Controls and Structures), which is an industry-standard software package for simulation and analysis of flexible multibody systems is presented. For systems involving many bodies, the new Order (n) version of DISCOS is much faster than the current version. Results of the experimental validation of the dynamics software are also presented. The experiment is carried out on a seven-joint robot arm at NASA's Goddard Space Flight Center. The algorithm used in the current version of DISCOS requires the inverse of a matrix whose dimension is equal to the number of constraints in the system. Generally, the number of constraints in a system is roughly proportional to the number of bodies in the system, and matrix inversion requires O(p exp 3) operations, where p is the dimension of the matrix. The current version of DISCOS is therefore considered an Order (n exp 3) algorithm. In contrast, the Order (n) algorithm requires inversion of matrices which are small, and the number of matrices to be inverted increases only linearly with the number of bodies. The newly-developed Order (n) DISCOS is currently capable of handling chain and tree topologies as well as multiple closed loops. Continuing development will extend the capability of the software to deal with typical robotics applications such as put-and-place, multi-arm hand-off and surface sliding

    Image lag optimisation in a 4T CMOS image sensor for the JANUS camera on ESA's JUICE mission to Jupiter

    Get PDF
    The CIS115, the imager selected for the JANUS camera on ESA’s JUICE mission to Jupiter, is a Four Transistor (4T) CMOS Image Sensor (CIS) fabricated in a 0.18 µm process. 4T CIS (like the CIS115) transfer photo generated charge collected in the pinned photodiode (PPD) to the sense node (SN) through the Transfer Gate (TG). These regions are held at different potentials and charge is transferred from the potential well under PPD to the potential well under the FD through a voltage pulse applied to the TG. Incomplete transfer of this charge can result in image lag, where signal in previous frames can manifest itself in subsequent frames, often appearing as ghosted images in successive readouts. This can seriously affect image quality in scientific instruments and must be minimised. This is important in the JANUS camera, where image quality is essential to help JUICE meet its scientific objectives. This paper presents two techniques to minimise image lag within the CIS115. An analysis of the optimal voltage for the transfer gate voltage is detailed where optimisation of this TG “ON” voltage has shown to minimise image lag in both an engineering model and gamma and proton irradiated devices. Secondly, a new readout method of the CIS115 is described, where following standard image integration, the PPD is biased to the reset voltage level (VRESET) through the transfer gate to empty charge on the PPD and has shown to reduce image lag in the CIS115

    Quantum fields and "Big Rip" expansion singularities

    Full text link
    The effects of quantized conformally invariant massless fields on the evolution of cosmological models containing a ``Big Rip'' future expansion singularity are examined. Quantized scalar, spinor, and vector fields are found to strengthen the accelerating expansion of such models as they approach the expansion singularity.Comment: 7 pages; REVTeX

    Alessi 95 and the short period Cepheid SU Cassiopeiae

    Get PDF
    The parameters for the newly-discovered open cluster Alessi 95 are established on the basis of available photometric and spectroscopic data, in conjunction with new observations. Colour excesses for spectroscopically-observed B and A-type stars near SU Cas follow a reddening relation described by E(U-B)/E(B-V)=0.83+0.02*E(B-V), implying a value of R=Av/E(B-V)~2.8 for the associated dust. Alessi 95 has a mean reddening of E(B-V)_(B0)=0.35+-0.02 s.e., an intrinsic distance modulus of Vo-Mv=8.16+-0.04 s.e. (+-0.21 s.d.), d=429+-8 pc, and an estimated age of 10^8.2 yr from ZAMS fitting of available UBV, CCD BV, NOMAD, and 2MASS JHKs observations of cluster stars. SU Cas is a likely cluster member, with an inferred space reddening of E(B-V)=0.33+-0.02 and a luminosity of =-3.15+-0.07 s.e., consistent with overtone pulsation (P_FM=2.75 d), as also implied by the Cepheid's light curve parameters, rate of period increase, and Hipparcos parallaxes for cluster stars. There is excellent agreement of the distance estimates for SU Cas inferred from cluster ZAMS fitting, its pulsation parallax derived from the infrared surface brightness technique, and Hipparcos parallaxes, which all agree to within a few percent.Comment: Accepted for Publication (MNRAS
    corecore