876 research outputs found
Star Formation in M51 Triggered by Galaxy Interaction
We have mapped the inner 360'' regions of M51 in the 158micron [CII] line at
55'' spatial resolution using the Far-infrared Imaging Fabry-Perot
Interferometer (FIFI) on the Kuiper Airborne Observatory (KAO). The emission is
peaked at the nucleus, but is detectable over the entire region mapped, which
covers much of the optical disk of the galaxy. There are also two strong
secondary peaks at ~43% to 70% of the nuclear value located roughly 120'' to
the north-east, and south-west of the nucleus. These secondary peaks are at the
same distance from the nucleus as the corotation radius of the density wave
pattern. The density wave also terminates at this location, and the outlying
spiral structure is attributed to material clumping due to the interaction
between M51 and NGC5195. This orbit crowding results in cloud-cloud collisions,
stimulating star formation, that we see as enhanced [CII] line emission. The
[CII] emission at the peaks originates mainly from photodissociation regions
(PDRs) formed on the surfaces of molecular clouds that are exposed to OB
starlight, so that these [CII] peaks trace star formation peaks in M51. The
total mass of [CII] emitting photodissociated gas is ~2.6x10^{8} M_{sun}, or
about 2% of the molecular gas as estimated from its CO(1-0) line emission. At
the peak [CII] positions, the PDR gas mass to total gas mass fraction is
somewhat higher, 3-17%, and at the secondary peaks the mass fraction of the
[CII] emitting photodissociated gas can be as high as 72% of the molecular
mass.... (continued)Comment: 14 pages, 6 figures, Accepted in ApJ (for higher resolution figures
contact the author
Measurement of the proton electric to magnetic form factor ratio from \vec ^1H(\vec e, e'p)
We report the first precision measurement of the proton electric to magnetic
form factor ratio from spin-dependent elastic scattering of longitudinally
polarized electrons from a polarized hydrogen internal gas target. The
measurement was performed at the MIT-Bates South Hall Ring over a range of
four-momentum transfer squared from 0.15 to 0.65 (GeV/c).
Significantly improved results on the proton electric and magnetic form factors
are obtained in combination with previous cross-section data on elastic
electron-proton scattering in the same region.Comment: 4 pages, 2 figures, submitted to PR
Removing krypton from xenon by cryogenic distillation to the ppq level
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the -emitter
Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10 mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.410 with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions
The Charge Form Factor of the Neutron at Low Momentum Transfer from the Reaction
We report new measurements of the neutron charge form factor at low momentum
transfer using quasielastic electrodisintegration of the deuteron.
Longitudinally polarized electrons at an energy of 850 MeV were scattered from
an isotopically pure, highly polarized deuterium gas target. The scattered
electrons and coincident neutrons were measured by the Bates Large Acceptance
Spectrometer Toroid (BLAST) detector. The neutron form factor ratio
was extracted from the beam-target vector asymmetry
at four-momentum transfers , 0.20, 0.29 and 0.42
(GeV/c).Comment: 5 pages, 3 figures, submitted to Phys. Rev. Let
Search for Two-Neutrino Double Electron Capture of Xe with XENON100
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of Xe using
7636 kgd of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
yr after an exposure of 2 tyr.Comment: 6 pages, 4 figure
Neural Network Parameterizations of Electromagnetic Nucleon Form Factors
The electromagnetic nucleon form-factors data are studied with artificial
feed forward neural networks. As a result the unbiased model-independent
form-factor parametrizations are evaluated together with uncertainties. The
Bayesian approach for the neural networks is adapted for chi2 error-like
function and applied to the data analysis. The sequence of the feed forward
neural networks with one hidden layer of units is considered. The given neural
network represents a particular form-factor parametrization. The so-called
evidence (the measure of how much the data favor given statistical model) is
computed with the Bayesian framework and it is used to determine the best form
factor parametrization.Comment: The revised version is divided into 4 sections. The discussion of the
prior assumptions is added. The manuscript contains 4 new figures and 2 new
tables (32 pages, 15 figures, 2 tables
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure
- …
