463 research outputs found

    Progress in Atomic Fountains at LNE-SYRTE

    Full text link
    We give an overview of the work done with the Laboratoire National de M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.Comment: 19 pages, 12 figures, 5 tables, 126 reference

    La inclinacion española

    Get PDF
    Copia digital. Valladolid : Junta de Castilla y León. Consejería de Cultura y Turismo, 2009-2010Contiene, además: El conde las legumbres, del mismo auto

    Improved tests of Local Position Invariance using 87Rb and 133Cs fountains

    Full text link
    We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.Comment: 5 pages, 3 figures, 3 tables, 34 reference

    Atomic fountains and optical clocks at SYRTE: status and perspectives

    Get PDF
    In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second

    Accurate spectroscopy of Sr atoms

    Full text link
    We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr : 1S03P1^1S_0- ^3P_1 at 689 nm, 3P13S1^3P_1- ^3S_1 at 688 nm and 3P03S1^3P_0- ^3S_1 at 679 nm. Measurements are performed with a frequency chain based on a femtosecond laser referenced to primary frequency standards. They allowed the indirect determination with a 70 kHz uncertainty of the frequency of the doubly forbidden 5s^2^1S_0- 5s5p^3P_0 transition of 87^{87}Sr at 698 nm and in a second step its direct observation. Frequency measurements are performed for 88^{88}Sr and 87^{87}Sr, allowing the determination of 3P0^3P_0, 3P1^3P_1 and 3S1^3S_1 isotope shifts, as well as the 3S1^3S_1 hyperfine constants.Comment: 12 pages, 16 figure

    Optical frequency measurement of the 1S-3S two-photon transition in hydrogen

    Full text link
    This article reports the first optical frequency measurement of the 1S3S1\mathrm{S}-3\mathrm{S} transition in hydrogen. The excitation of this transition occurs at a wavelength of 205 nm which is obtained with two frequency doubling stages of a titanium sapphire laser at 820 nm. Its frequency is measured with an optical frequency comb. The second-order Doppler effect is evaluated from the observation of the motional Stark effect due to a transverse magnetic field perpendicular to the atomic beam. The measured value of the 1S1/2(F=1)3S1/2(F=1)1\mathrm{S}_{1/2}(F=1)-3\mathrm{S}_{1/2}(F=1) frequency splitting is 2922742936.729(13)MHz2 922 742 936.729 (13) \mathrm{MHz} with a relative uncertainty of 4.5×10124.5\times10^{-12}. After the measurement of the 1S2S1\mathrm{S}-2\mathrm{S} frequency, this result is the most precise of the optical frequencies in hydrogen

    Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms

    Full text link
    We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.Comment: 3 pages, 4 figures, uses ol.sty fil

    An accurate optical lattice clock with 87Sr atoms

    Get PDF
    We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2x10^{-13}, i.e. almost four times the combined error bar, instilling doubt on the potential of optical lattice clocks to perform at a high accuracy level. In perfect agreement with one of these two values, our measurement essentially dissipates this doubt
    corecore