248 research outputs found

    Classical Limit of Demagnetization in a Field Gradient

    Full text link
    We calculate the rate of decrease of the expectation value of the transverse component of spin for spin-1/2 particles in a magnetic field with a spatial gradient, to determine the conditions under which a previous classical description is valid. A density matrix treatment is required for two reasons. The first arises because the particles initially are not in a pure state due to thermal motion. The second reason is that each particle interacts with the magnetic field and the other particles, with the latter taken to be via a 2-body central force. The equations for the 1-body Wigner distribution functions are written in a general manner, and the places where quantum mechanical effects can play a role are identified. One that may not have been considered previously concerns the momentum associated with the magnetic field gradient, which is proportional to the time integral of the gradient. Its relative magnitude compared with the important momenta in the problem is a significant parameter, and if their ratio is not small some non-classical effects contribute to the solution. Assuming the field gradient is sufficiently small, and a number of other inequalities are satisfied involving the mean wavelength, range of the force, and the mean separation between particles, we solve the integro- partial differential equations for the Wigner functions to second order in the strength of the gradient. When the same reasoning is applied to a different problem with no field gradient, but having instead a gradient to the z-component of polarization, the connection with the diffusion coefficient is established, and we find agreement with the classical result for the rate of decrease of the transverse component of magnetization.Comment: 22 pages, no figure

    Simulations of Quantum Logic Operations in Quantum Computer with Large Number of Qubits

    Get PDF
    We report the first simulations of the dynamics of quantum logic operations with a large number of qubits (up to 1000). A nuclear spin chain in which selective excitations of spins is provided by the gradient of the external magnetic field is considered. The spins interact with their nearest neighbors. We simulate the quantum control-not (CN) gate implementation for remote qubits which provides the long-distance entanglement. Our approach can be applied to any implementation of quantum logic gates involving a large number of qubits.Comment: 13 pages, 15 figure

    Persistent Current in the Ferromagnetic Kondo Lattice Model

    Full text link
    In this paper, we study the zero temperature persistent current in a ferromagnetic Kondo lattice model in the strong coupling limit. In this model, there are spontaneous spin textures at some values of the external magnetic flux. These spin textures contribute a geometric flux, which can induce an additional spontaneous persistent current. Since this spin texture changes with the external magnetic flux, we find that there is an anomalous persistent current in some region of magnetic flux: near Phi/Phi_0=0 for an even number of electrons and Phi/Phi_0=1/2 for an odd number of electrons.Comment: 6 RevTeX pages, 10 figures include

    Dynamic nuclear polarization and spin-diffusion in non-conducting solids

    Full text link
    There has been much renewed interest in dynamic nuclear polarization (DNP), particularly in the context of solid state biomolecular NMR and more recently dissolution DNP techniques for liquids. This paper reviews the role of spin diffusion in polarizing nuclear spins and discusses the role of the spin diffusion barrier, before going on to discuss some recent results.Comment: submitted to Applied Magnetic Resonance. The article should appear in a special issue that is being published in connection with the DNP Symposium help in Nottingham in August 200

    Fourier Magnetic Imaging with Nanoscale Resolution and Compressed Sensing Speed-up using Electronic Spins in Diamond

    Full text link
    Optically-detected magnetic resonance using Nitrogen Vacancy (NV) color centres in diamond is a leading modality for nanoscale magnetic field imaging, as it provides single electron spin sensitivity, three-dimensional resolution better than 1 nm, and applicability to a wide range of physical and biological samples under ambient conditions. To date, however, NV-diamond magnetic imaging has been performed using real space techniques, which are either limited by optical diffraction to 250 nm resolution or require slow, point-by-point scanning for nanoscale resolution, e.g., using an atomic force microscope, magnetic tip, or super-resolution optical imaging. Here we introduce an alternative technique of Fourier magnetic imaging using NV-diamond. In analogy with conventional magnetic resonance imaging (MRI), we employ pulsed magnetic field gradients to phase-encode spatial information on NV electronic spins in wavenumber or k-space followed by a fast Fourier transform to yield real-space images with nanoscale resolution, wide field-of-view (FOV), and compressed sensing speed-up.Comment: 31 pages, 10 figure

    Обзор рынка по оказанию услуг поддержки принятия решений

    Get PDF
    Cardiovascular Magnetic Resonance (CVMR) imaging has proven to be of clinical value for non-invasive diagnostic imaging of cardiovascular diseases. CVMR requires rapid imaging; however, the speed of conventional MRI is fundamentally limited due to its sequential approach to image acquisition, in which data points are collected one after the other in the presence of sequentially-applied magnetic field gradients and radiofrequency pulses. Parallel MRI uses arrays of radiofrequency coils to acquire multiple data points simultaneously, and thereby to increase imaging speed and efficiency beyond the limits of purely gradient-based approaches. The resulting improvements in imaging speed can be used in various ways, including shortening long examinations, improving spatial resolution and anatomic coverage, improving temporal resolution, enhancing image quality, overcoming physiological constraints, detecting and correcting for physiologic motion, and streamlining work flow. Examples of these strategies will be provided in this review, after some of the fundamentals of parallel imaging methods now in use for cardiovascular MRI are outlined. The emphasis will rest upon basic principles and clinical state-of-the art cardiovascular MRI applications. In addition, practical aspects such as signal-to-noise ratio considerations, tailored parallel imaging protocols and potential artifacts will be discussed, and current trends and future directions will be explored

    Spatial aspects of nuclear magnetic resonance spectroscopy : static and radio-frequency magnetic field gradients in principle and practice

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Whitaker College of Health Sciences and Technology, 1997.Includes bibliographical references (p. 131-132).by Aaron David Sodickson.Ph.D

    Neuronal activity under transcranial radio-frequency stimulation in metal-free rodent brains in-vivo

    Get PDF
    As the use of Radio Frequency (RF) technologies increases, the impact of RF radiation on neurological function continues to receive attention. Whether RF radiation can modulate ongoing neuronal activity by non-thermal mechanisms has been debated for decades. However, the interactions between radiated energy and metal-based neural probes during experimentation could impact neural activity, making interpretation of the results difficult. To address this problem, we modified a miniature 1-photon Ca2+ imaging device to record interference-free neural activity and compared the results to those acquired using metal-containing silicon probes. We monitored the neuronal activity of awake rodent-brains under RF energy exposure (at 950 MHz) and in sham control paradigms. Spiking activity was reliably affected by RF energy in metal containing systems. However, we did not observe neuronal responses using metal-free optical recordings at induced local electric field strengths up to 230 V/m. Our results suggest that RF exposure higher than levels that are allowed by regulatory limits in real-life scenarios do not affect neuronal activity

    Effects of anatomical differences on electromagnetic fields, SAR, and temperature change

    Get PDF
    Electromagnetic field simulations are increasingly used to assure RF safety of patients during MRI exams. In practice, however, tissue property distribution of the patient being imaged is not known, but may be represented with a pre-existing model. Repeatedly, agreement in transmit magnetic ( B1+) field distributions between two geometries has been used to suggest agreement in heating distributions. Here we examine relative effects of anatomical differences on B1+ distribution, specific absorption rate (SAR), and temperature change (ΔT). Numerical simulations were performed for a single surface coil positioned adjacent a homogeneous phantom and bovine phantom, each with slight geometric variations, and adjacent two different human body models. Experimental demonstration was performed on a bovine phantom using MR thermometry and B1+ mapping. Simulations and experiments demonstrate that B1+ distributions in different samples can be well correlated, while notable difference in maximum SAR and ΔT occur. This work illustrates challenges associated with utilizing simulations or experiments for RF safety assurance purposes. Reliance on B1+ distributions alone for validation of simulations and/or experiments with a sample or subject for assurance of safety in another should be performed with caution
    corecore