    Use of Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry to Demonstrate Decreased Serum Statin Levels after Extracorporeal LDL-Cholesterol Elimination

    Get PDF
    Background. Using our statin analysis method, it was possible to uncover a significant drop in statin levels (atorvastatin, simvastatin, and metabolites) after extracorporeal LDL-cholesterol elimination (EE) in severe familial hypercholesterolemia (FH). The purpose of this work was to identify the mechanism underlying this drop and its clinical significance as well as to propose measures to optimize a pharmacotherapeutical regimen that can prevent the loss of statins. Methods. Ultra High Performance Liquid Chromatography (UHPLC) connected to the triple quadrupole MS/MS system was used. Patients. A group of long-term treated patients (3–12 years of treatment) with severe FH (12 patients) and treated regularly by LDL-apheresis (immunoadsorption) or haemorheopheresis (cascade filtration) were included in this study. Results. After EE, the level of statins and their metabolites decreased (atorvastatin before/after LDL-apheresis: 8.83/3.46 nmol/l; before/after haemorheopheresis: 37.02/18.94 nmol/l). A specific loss was found (concentration of atorvastatin for LDL-apheresis/haemorheopheresis: 0.28/3.04 nmol/l in washing fluids; 11.07 nmol/l in filters). To prevent substantial loss of statin concentrations, a pharmacotherapeutic regimen with a longer time interval between the dose of statins and EE is recommended (15 hours). Conclusions. A specific loss of statins was found in adsorbent columns and filters. The decrease can be prevented by the suggested dosage scheme

    Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gel

    No full text
    The performance of monolithic HPLC columns Chromolith™ (made by Merck, Germany) and conventional C18 columns Discovery (Supelco, Sigma-Aldrich, Prague, Czech Republic) was tested and the comparison for two topical preparations Ketoprofen gel and Estrogel gel was made. The composition of mobile phases - for Ketoprofen analysis a mixture of acetonitrile, water and phosphate buffer adjusted to pH 3.5 (40:58:2) and for Estrogel analysis a mixture of acetonitrile, methanol, water (23:24:53) - was usually not optimal for analyses at all types of columns. Thus an adjustment of components ratio was necessary for sufficient resolution of the compounds analysed. Various flow rates (1.0-5.0 ml/min) and mobile phases (usually increasing ratio of water content) were applied. Determination of active substances, preservatives and impurities and comparison of retention times and system suitability test parameters was accomplished. For Estrogel gel, following chromatographic conditions were found: using Chromolith Flash RP-18e monolith column, mobile phase was acetonitrile, methanol, water (13:24:63, v/v/v) and flow-rate 3.0 ml/min. Using monolith column ChromolithSpeedROD RP-18e, the mobile phase was acetonitrile, methanol, water (18:24:58, v/v/v) and flow-rate 4.0 ml/min. For the monolith column Chromolith Performance RP-18e, the mobile phase was acetonitrile, methanol, water (23:24:53, v/v/v), flow-rate 3.0 ml/min. Analysis of Ketoprofen gel gave the best results using following analytical conditions: for monolith column Chromolith Flash RP-18e, mobile phase as a mixture of acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) was used, at flow-rate 2.0 ml/min. For ChromolithSpeedROD RP-18e monolith column, acetonitrile, water, phosphate buffer pH 3.5 (35:63:2, v/v/v) was used as a mobile phase at flow-rate 3.0 ml/min. Chromolith Performance RP-18e gave the best results using mobile phase acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) at the flow-rate 5.0 ml/min. It was proved that monolith columns, due to their porosity and low back-pressure, can save analysis time by about a factor of three with sufficient separation efficiency. Thus, for example 11 min long analysis can be performed in 4 min with comparable results. © 2004 Elsevier B.V. All rights reserved

    Increased urinary neopterin in acute myocardial infarction

    Full text link
    corecore