804 research outputs found
Dominant g(9/2)^2 neutron configuration in the 4+1 state of 68Zn based on new g factor measurements
The factor of the state in Zn has been remeasured with
improved energy resolution of the detectors used. The value obtained is
consistent with the previous result of a negative factor thus confirming
the dominant neutron nature of the state. In addition, the
accuracy of the factors of the , and states has been
improved an d their lifetimes were well reproduced. New large-scale shell model
calculations based on a Ni core and an model space
yield a theoretical value, . Although the calculated value
is small, it cannot fully explain the experimental value, . The magnitude of the deduced B(E2) of the and
transition is, however, rather well described. These results demonstrate again
the importance of factor measurements for nuclear structure determination s
due to their specific sensitivity to detailed proton and neutron components in
the nuclear wave functions.Comment: 7 pages, 3 figs, submitted to PL
Elastic properties of grafted microtubules
We use single-particle tracking to study the elastic properties of single
microtubules grafted to a substrate. Thermal fluctuations of the free
microtubule's end are recorded, in order to measure position distribution
functions from which we calculate the persistence length of microtubules with
contour lengths between 2.6 and 48 micrometers. We find the persistence length
to vary by more than a factor of 20 over the total range of contour lengths.
Our results support the hypothesis that shearing between protofilaments
contributes significantly to the mechanics of microtubules.Comment: 9 pages, 3 figure
Factors associated with crisis pregnancies in Ireland: Findings from three nationally representative sexual health surveys
Background: Findings on the demographic and sexual health characteristics associated with the experience of a crisis pregnancy is important to inform the public health policy of a country, including Ireland. Findings from other jurisdictions have suggested that certain demographic groups are at risk for unintended pregnancies and the disparity between the groups have been growing in recent years. Ireland is a country which experienced much economic and societal change in the first decade of the 21st century, changes which are likely to have affected demographic variables pertaining to sexual health. The current study had two aims: to investigate changes in the socioeconomic characteristics associated with crisis pregnancies over a seven year period [2003 to 2010], and to investigate the recent [2010] socioeconomic risk factors associated with crisis pregnancies in Ireland.
Methods: The study compared the results from 18-45 year old women using data from three broadly similar nationally representative Irish sexual health surveys carried out in 2003, 2004-2006 and 2010. Chi square analysis compared of the socioeconomic characteristics across the seven year period and found that a higher proportion of women with two or more children and women for whom religion was not important reported a crisis pregnancy in 2010 compared with earlier years. A logistic regression then investigated the sexual health history and socioeconomic factors associated with the experience of a recent crisis pregnancy using the most recent 2010 data.
Results: Receipt of sex education and contraception use at first sex significantly predicted the experiencing of a recent crisis pregnancy. Younger women and those with a lower level of education were more likely to report having experienced a recent crisis pregnancy.
Conclusion: Similar demographic groups are at risk for experiencing a crisis pregnancy in Ireland compared with international research, yet the disparities between demographic groups who have experienced a crisis pregnancy appear to be decreasing rather than increasing over a seven year period. Recommendations are made with regard to the provision of continued sex education throughout the lifespan, particularly for those women who are at an increased risk of experiencing a crisis pregnancy
Systematics of collective correlation energies from self-consistent mean-field calculations
The collective ground-state correlations stemming from low-lying quadrupole
excitations are computed microscopically. To that end, the self-consistent
mean-field model is employed on the basis of the Skyrme-Hartre-Fock (SHF)
functional augmented by BCS pairing. The microscopic-macroscopic mapping is
achieved by quadrupole-constrained mean-field calculations which are processed
further in the generator-coordinate method (GCM) at the level of the Gaussian
overlap approximation (GOA).
We study the correlation effects on energy, charge radii, and surface
thickness for a great variety of semi-magic nuclei. A key issue is to work out
the influence of variations of the SHF functional. We find that collective
ground-state correlations (GSC) are robust under change of nuclear bulk
properties (e.g., effective mass, symmetry energy) or of spin-orbit coupling.
Some dependence on the pairing strength is observed. This, however, does not
change the general conclusion that collective GSC obey a general pattern and
that their magnitudes are rather independent of the actual SHF parameters.Comment: 13 pages, 13 figure
Comparative validation of single-shot optical techniques for laparoscopic 3-D surface reconstruction
Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper
Graduate-Level Distance Learning: Enhanced Student Experience, Significant Scalability Challenges: A Multiyear Case Study
Magnetic moments of Coulomb excited states for radioactive beams of Te and Xe isotopes at REX-ISOLDE
SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction
In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surface properties and the presence of blood and smoke. These issues present difficulties for both stereo reconstruction itself and also for standardised dataset production. Previous datasets have been produced using computed tomography (CT) or structured light reconstruction on phantom or ex vivo models. We present a stereo-endoscopic reconstruction validation dataset based on cone-beam CT (SERV-CT). Two ex vivo small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Subsequent orientation of the endoscope was manually aligned to match the stereoscopic view and benchmark disparities, depths and occlusions are calculated. The requirement of a CT scan limited the number of stereo pairs to 8 from each ex vivo sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of around 2 pixels and a depth accuracy of about 2 mm. A simplified reference dataset is provided consisting of endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types, including smooth specular surfaces, as well as significant variation of depth. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths covering the majority of the endoscopic image. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms
Measurement of the magnetic moment of the 2 state in neutron-rich radioactive Zn using the transient field technique in inverse kinematics
- …
