111 research outputs found

    Establishing a library of resources to help people understand key concepts in assessing treatment claims—The “Critical thinking and Appraisal Resource Library” (CARL)

    Get PDF
    Background People are frequently confronted with untrustworthy claims about the effects of treatments. Uncritical acceptance of these claims can lead to poor, and sometimes dangerous, treatment decisions, and wasted time and money. Resources to help people learn to think critically about treatment claims are scarce, and they are widely scattered. Furthermore, very few learning-resources have been assessed to see if they improve knowledge and behavior. Objectives Our objectives were to develop the Critical thinking and Appraisal Resource Library (CARL). This library was to be in the form of a database containing learning resources for those who are responsible for encouraging critical thinking about treatment claims, and was to be made available online. We wished to include resources for groups we identified as ‘intermediaries’ of knowledge, i.e. teachers of schoolchildren, undergraduates and graduates, for example those teaching evidence-based medicine, or those communicating treatment claims to the public. In selecting resources, we wished to draw particular attention to those resources that had been formally evaluated, for example, by the creators of the resource or independent research groups. Methods CARL was populated with learning-resources identified from a variety of sources—two previously developed but unmaintained inventories; systematic reviews of learning-interventions; online and database searches; and recommendations by members of the project group and its advisors. The learning-resources in CARL were organised by ‘Key Concepts’ needed to judge the trustworthiness of treatment claims, and were made available online by the James Lind Initiative in Testing Treatments interactive (TTi) English (www.testingtreatments.org/category/learning-resources).TTi English also incorporated the database of Key Concepts and the Claim Evaluation Tools developed through the Informed Healthcare Choices (IHC) project (informedhealthchoices.org). Results We have created a database of resources called CARL, which currently contains over 500 open-access learning-resources in a variety of formats: text, audio, video, webpages, cartoons, and lesson materials. These are aimed primarily at ‘Intermediaries’, that is, ‘teachers’, ‘communicators’, ‘advisors’, ‘researchers’, as well as for independent ‘learners’. The resources included in CARL are currently accessible at www.testingtreatments.org/category/learning-resources Conclusions We hope that ready access to CARL will help to promote the critical thinking about treatment claims, needed to help improve healthcare choices

    Electrocardiographic imaging demonstrates electrical synchrony improvement by dynamic atrioventricular delays in patients with left bundle branch block and preserved atrioventricular conduction

    Get PDF
    Aims: Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). Methods and results: Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. Conclusion: Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization

    Catheter ablation of atrial fibrillation in patients with hypertrophic cardiomyopathy: a European observational multicentre study

    Get PDF
    AIMS: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. METHODS AND RESULTS: Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52-0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. CONCLUSION: Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation

    Evaluation of the Re-entry Vulnerability Index to Predict Ventricular Tachycardia Circuits Using High Density Contact Mapping

    Get PDF
    BackgroundIdentifying arrhythmogenic sites to improve ventricular tachycardia (VT) ablation outcomes remains unresolved. The re-entry vulnerability index (RVI) combines activation and repolarization timings to identify sites critical for re-entrant arrhythmia initiation without inducing VT.ObjectiveTo provide the first assessment of RVI’s capability to identify VT sites of origin using high-density contact mapping and comparison with other activation-repolarization markers of functional substrate.Methods18 VT ablation patients (16M, 72% ischemic) were studied. Unipolar electrograms were recorded during ventricular pacing and analysed off-line. Activation time (AT), activation-recovery interval (ARI), repolarization time (RT) were measured. Vulnerability to re-entry was mapped based on RVI and spatial distribution of AT, ARI and RT. The distance from sites identified as vulnerable to re-entry to the VT site of origin was measured, with distances &lt;10 mm and &gt;20 mm indicating accurate and inaccurate localization, respectively.ResultsThe origin of 18 VTs was identified (n=6 entrainment, n=12 pace-mapping). RVI maps included 1012, 408—2098 (median, 1st—3rd quartiles) points/patient. RVI accurately localized 72.2% VT sites of origin, with median distance equal to 5.1, 3.2—10.1 mm. Inaccurate localization was significantly less frequent for RVI than AT (5.6% vs 33.3%, OR=0.12, P=0.035). Compared to RVI, distance to VT sites of origin was significantly larger for sites showing prolonged RT and ARI, and non-significantly larger for sites showing highest AT and ARI gradients.ConclusionRVI identifies vulnerable regions closest to VT sites of origin. Activation-repolarization metrics may improve VT substrate delineation and inform novel ablation strategies.</p

    Blister Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use

    Get PDF
    BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (ICER, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients

    Dual-site right ventricular pacing in patients undergoing cardiac resynchronization therapy: Results of a multicenter propensity-matched analysis

    Get PDF
    BACKGROUND: Dual-site right ventricular pacing (Dual RV) has been proposed as an alternative for patients with heart failure undergoing cardiac resynchronization therapy (CRT) with a failure to deliver a coronary sinus (CS) lead. Only short-term hemodynamic and echocardiographic results of Dual RV are available. We aimed to assess the long-term results of Dual RV and its impact on survival. METHODS: Multicenter retrospective assessment of all CRT implants during a 12-year period. Patients with failed CS lead implantation, treated with Dual RV, were followed and assessed for the primary endpoint of all-cause mortality and/or heart transplant. A control group was obtained from contemporary patients using propensity matching for all available baseline variables. RESULTS: Ninety-three patients were implanted with Dual RV devices and compared with 93 matched controls. During a median of 1,273 days (interquartile range 557-2,218), intention-to-treat analysis showed that all-cause mortality and/or heart transplant was higher in the Dual RV group (adjusted hazard ratio [HR] = 1.66, 95% confidence interval [CI] 1.12-2.47, P = 0.012). As-treated analysis yielded similar results (HR = 1.97, 95% CI 1.31-2.96, P = 0.001). Cardiac device-related infections occurred seven times more frequently in the Dual RV site group (HR = 7.60, 95% CI 1.51-38.33, P = 0.014). Among Dual RV nonresponders, four had their apical leads switched off, five required an epicardial LV lead insertion, a transseptal LV lead was implanted in two, and in nine patients, after reviewing the CS venogram, a new CS lead insertion was successfully attempted. CONCLUSION: Dual RV pacing is associated with worse clinical outcomes and higher complication rates than conventional CRT

    Procedural and quality assessment data on catheter ablation for fascicular ventricular tachycardia

    Get PDF
    Data presented in this article are supplementary materials to our article entitled “Catheter Ablation for Fascicular Ventricular Tachycardia: A Systematic review” (Creta et al., 2018). The current article provides additional procedural data regarding the catheter ablation for fascicular ventricular tachycardia (FVT) performed in the patients enrolled in our analysis. Furthermore, we provide data regarding the quality assessment of the studies included in our systematic review

    Amplified sinus-P-wave analysis predicts outcomes of cryoballoon ablation in patients with persistent and long-standing persistent atrial fibrillation: A multicentre study

    Get PDF
    IntroductionOutcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI).MethodsObservational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW &lt; 150 ms.ResultsWe included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW &lt; 150 ms (57.0% vs. 41.6%; log-rank p &lt; 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28–3.21; p = 0.002).ConclusionAPW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach
    corecore