22 research outputs found

    The Quality of Romanian Honey Varieties - Mineral Content and Textural Properties

    Get PDF
    The viscosity, flow behaviour index, consistency index and mineral content of severalhoney varieties were measured for four consecutive years (2009-2011). Potassium concentration hadthe most impressive variation from 532 mg/kg in 2009 for the sunflower honey variety to 112,5mg/kgin 2010 for the rapeseed plant honey. Strontium concentrations were less than 0.3 mg/kg, howeverfurther investigation is needed in order to certify these findings. We have suggested that honeyviscosity and its variation with temperature may be a relevant quality parameter due especially toconsumers’ preference for high viscosity honey varieties

    Exploratory survey on european consumer and stakeholder attitudes towards alternatives for surgical castration of piglets

    Get PDF
    Surgical castration of piglets without pain relief is still common practice in many countries. Possible alternatives for surgical castration are application of pain relief or anaesthesia or production of boars (entire males) and immunocastrates. Each of these alternatives faces advantages and disadvantages which may result in different citizen attitudes and consumers acceptability. Understanding which practice is acceptable to whom and why may further stimulate implementation. Consumer (n = 3251) and stakeholder (n = 1027) attitudes towards surgical castration without pain relief, surgical castration with anaesthesia, immunocastration, and production of boars were surveyed from April to June 2020 via an online questionnaire in 16 countries (>175 respondents per country). Surgical castration without pain relief was separated from each of the alternatives due to animal welfare and showed the lowest acceptability (32%). Within the alternatives, a further partitioning between the alternatives was based on perceived quality and food safety, with an acceptance of 85% for applying anaesthesia, 71% for immunocastration, and 49% for boar production. Differences depending on professional involvement and familiarity with agriculture could be observed, mainly for the acceptance of surgical castration without anaesthesia, immunocastration, and boars. Castration with anaesthesia was highly accepted by all types of respondents

    Reshapeable visualizations

    No full text

    P713 An incidental finding of a completely thrombosed left ventricular pseudoaneurysm: what is the next step?

    Full text link
    Abstract Introduction Left ventricular pseudoaneurysm is a rare complication of myocardial infarction. It is the result of ventricular rupture contained by the pericardial adhesions or thrombus. Although echocardiography is suitable as the initial method for diagnosis, multimodality imaging is often required in order to further characterize the pseudoaneurysm morphology and to plan the treatment. Case report A 56-year-old male patient with an old inferior myocardial infarction treated conservatively 6 years ago, was admitted in our department for atypical left laterothoracic pain. Three months before he had the same symptoms and an unexplained paracardiac mass was incidentally diagnosed by transthoracic echocardiography. At that time, he was evaluated by coronary angiography which showed no epicardial coronary artery stenosis. During admission, the ECG showed sinus rhythm, inferior myocardial scarring and right bundle branch block. The laboratory tests revealed cardiac enzymes within normal range, increased D-dimeri and elevated inflammatory markers. The echocardiography showed a nondilated left ventricle (LV) with preserved ejection fraction and akinesia of the inferolateral(IL) LV wall. Attached to the basal IL LV wall, an extensive mass was documented with an echogenic appearance and no color Doppler flow, suggesting a thrombosed pseudoaneurysm. A contrast enhanced computed tomography (CT) scan confirmed the diagnosis, but it was not able to establish whether the pseudoaneurysm was partially or completely thrombosed. For a more accurate morphologic and tissue characterization, a cardiac magnetic resonance imaging(CMR) was subsequently performed, that confirmed the presence of a completely thrombosed pseudoaneurysm, measuring 82x38mm. In this case, a conservative approach was initially suggested by the completely thrombosed chronic pseudoaneurysm (older than 3months and with no Doppler color flow). However, according to the literature a surgical approach should be considered when the pseudoaneurysm dimension is larger than 3 cm. Since the patient refused the surgical intervention, medical treatment was initiated with anticoagulants due to the high embolic risk, betablockers and angiotensin-receptor antagonists to maintain the blood pressure less than 120/80mmHg. At 1 month, his condition was stable. He will be reevaluated in 3 months, to monitor the possible pseudoaneurysm expansion. According to our knowledge, this is the first case of a completely thrombosed pseudoaneurysm described in the literature. Its echocardiographic, CT and CMR appearance is important for the differential diagnosis of all paracardiac masses (tumors, hiatus hernias, etc). Conclusion Completely thrombosed left ventricle pseudoaneurysm remains a challenging diagnosis since its echocardiographic appearance is atypical. Cardiac magnetic resonance imaging has a higher diagnostic yield and can provide important information that may influence the course of treatment. Abstract P713 Figure. LV Pseudoaneurysm-multimodality imaging </jats:sec

    The Genetic Code—More Than Just a Table

    Full text link

    Effect of Control-Display Gain and Mapping and Use of Armrests on Accuracy in Temporally Limited Touchless Gestural Steering Tasks

    No full text
    Touchless gestural controls are becoming an important natural input technique for interaction with emerging virtual environments but design parameters that improve task performance while at the same time reduce user fatigue require investigation. This experiment aims to understand how control-display (CD) parameters such as gain and mapping as well as the use of armrests affect gesture accuracy in specific movement directions. Twelve participants completed temporally constrained two-dimensional steering tasks using free-hand fingertip gestures in several conditions. Use of an armrest, increased CD gain, and horizontal mapping significantly reduced success rate. The results show that optimal transfer functions for gestures will depend on the movement direction as well as arm support features
    corecore