98 research outputs found

    18F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports

    Get PDF
    ABSTRACT: BACKGROUND: F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 cm. CASE PRESENTATION: We report five cases of oncologic patients showing focal lung 18F-FDG uptake on PET-CT in nodules smaller than 1 cm. We also discuss the most common causes of 18F-FDG false-positive and false-negative results in the pulmonary parenchyma. In patient 1, contrast-enhanced CT performed 10 days before PET-CT did not show any abnormality in the site of uptake; in patient 2, high-resolution CT performed 1 month after PET showed a bronchiole filled with dense material interpreted as a mucoid impaction; in patient 3, contrast-enhanced CT performed 15 days before PET-CT did not identify any nodules; in patients 4 and 5, contrast-enhanced CT revealed a nodule smaller than 1 cm which could not be characterized. The 18F-FDG uptake at follow-up confirmed the malignant nature of pulmonary nodules smaller than 1 cm which were undetectable, misinterpreted, not recognized or undetermined at contrast-enhanced CT. CONCLUSION: In all five oncologic patients, 18F-FDG was able to metabolically characterize as malignant those nodules smaller than 1 cm, underlining that: 18F-FDG uptake is not only a function of tumor size but it is strongly related to the tumor biology; functional alterations may precede morphologic abnormalities. In the oncologic population, especially in higher-risk patients, PET can be performed even when the nodules are smaller than 1 cm, because it might give an earlier characterization and, sometimes, could guide in the identification of alterations missed on CT

    RECIST revised: implications for the radiologist. A review article on the modified RECIST guideline

    Get PDF
    The purpose of this review article is to familiarize radiologists with the recently revised Response Evaluation Criteria in Solid Tumours (RECIST), used in many anticancer drug trials to assess response and progression rate. The most important modifications are: a reduction in the maximum number of target lesions from ten to five, with a maximum of two per organ, with a longest diameter of at least 10 mm; in lymph nodes (LNs) the short axis rather than the long axis should be measured, with normal LN measuring <10 mm, non-target LN ≥10 mm but <15 mm and target LN ≥15 mm; osteolytic lesions with a soft tissue component and cystic tumours may serve as target lesions; an additional requirement for progressive disease (PD) of target lesions is not only a ≥20% increase in the sum of the longest diameter (SLD) from the nadir but also a ≥5 mm absolute increase in the SLD (the other response categories of target lesion are unchanged); PD of non-target lesions can only be applied if the increase in non-target lesions is representative of change in overall tumour burden; detailed imaging guidelines. Alternative response criteria in patients with hepatocellular carcinoma and gastrointestinal stromal tumours are discussed

    Der pulmonale Rundherd: Detektion, Charakterisierung

    Full text link

    Mykobakterielle Infektionen

    Full text link

    Staging thorakaler Tumoren – Lungenkarzinom

    Full text link

    Pro und Contra im Lungenkarzinom-Screening

    Full text link

    Abklärung von Lungenrundherden

    Full text link

    Klinischer Einsatz von CAD in der Thoraxradiologie – Aktueller Stand

    Full text link

    Stellenwert der Thorax-CAD in der klinischen Routine

    Full text link
    corecore