1,173 research outputs found

    Small Satellite Industrial Base Study: Foundational Findings

    Get PDF
    This report documents findings from a Small Satellite (SmallSat) Industrial Base Study conducted by The Aerospace Corporation between November 2018 and September 2019. The primary objectives of this study were a) to gain a better understanding of the SmallSat communitys technical practices, engineering approaches, requirements flow-downs, and common processes and b) identify insights and recommendations for how the government can further capitalize on the strengths and capabilities of SmallSat offerings. In the context of this study, SmallSats are understood to weigh no more than 500 kg, as described in State of the Art Small Spacecraft Technology, NASA/TP-2018- 220027, December 2018. CubeSats were excluded from this study to avoid overlap and duplication of recently completed work or other studies already under way. The team also touched on differences between traditional space-grade and the emerging mid-grade and other non-space, alternate-grade EEEE (electrical, electronic, electromechanical, electro-optical) piece part categories. Finally, the participants sought to understand the potential effects of increased use of alternate-grade parts on the traditional space-grade industrial base. The study team was keenly aware that there are missions for which non-space grade parts currently are infeasible for the foreseeable future. National security, long-duration and high-reliability missions intolerant of risk are a few examples. The team sought to identify benefits of alternative parts and approaches that can be harnessed by the government to achieve greater efficiencies and capabilities without impacting mission success

    Epidemiology, clinical characteristics, and antimicrobial susceptibility profiles of human clinical isolates of Staphylococcus intermedius group

    Get PDF
    ABSTRACT The veterinary pathogens in the Staphylococcus intermedius group (SIG) are increasingly recognized as causes of human infection. Shared features between SIG and Staphylococcus aureus may result in the misidentification of SIG in human clinical cultures. This study examined the clinical and microbiological characteristics of isolates recovered at a tertiary-care academic medical center. From 2013 to 2015, 81 SIG isolates were recovered from 62 patients. Patients were commonly ≥50 years old, diabetic, and/or immunocompromised. Documentation of dog exposure in the electronic medical record was not common. Of the 81 SIG isolates, common sites of isolation included 37 (46%) isolates from wound cultures and 17 (21%) isolates from respiratory specimens. Although less common, 10 (12%) bloodstream infections were documented in 7 unique patients. The majority of SIG (65%) isolates were obtained from polymicrobial cultures. In comparison to S. aureus isolates from the same time period, significant differences were noted in proportion of SIG isolates that were susceptible to doxycycline (74% versus 97%, respectively; P &lt; 0.001), trimethoprim-sulfamethoxazole (65% versus 97%, respectively; P &lt; 0.001), and ciprofloxacin (78% versus 59%, respectively; P &lt; 0.01). Methicillin resistance (MR) was detected in 12 (15%) of 81 SIG isolates. All MR isolates detected by an oxacillin disk diffusion test would have been misclassified as methicillin susceptible using a cefoxitin disk diffusion test. Thus, SIG is recovered from human clinical specimens, and distinction of SIG from S. aureus is critical for the accurate characterization of MR status in these isolates. </jats:p

    Culture of urine specimens by use of chromID CPS Elite medium can expedite Escherichia coli identification and reduce hands-on time in the clinical laboratory

    Get PDF
    Urine is one of the most common specimen types submitted to the clinical microbiology laboratory; the use of chromogenic agar is one method by which the laboratory might expedite culture results and reduce hands-on time and materials required for urine culture analysis. The objective of our study was to compare chromID CPS Elite (bioMérieux), a chromogenic medium, to conventional primary culture medium for evaluation of urine specimens. Remnant urine specimens (n = 200) were inoculated into conventional media and into chromID CPS Elite agar (chromID). The time to identification and consumables used were documented for both methods. Clinically significant pathogen(s) were recovered from 51 cultures using conventional media, with Escherichia coli being the most frequently recovered organism (n = 22). The rate of exact uropathogen agreement between conventional and chromogenic media was 82%, while overall categorical agreement was 83.5% The time interval between plating and final organism identification was decreased with chromID agar versus conventional media for E. coli (mean of 24.4 h versus 27.1 h, P < 0.001). Using chromID, clinically significant cultures required less hands-on time per culture (mean of 1 min and 2 s [1:02 min]) compared to conventional media (mean of 1:31 min). In addition, fewer consumables (2.4 versus 3.3 sticks and swabs) and rapid biochemical tests (1.0 versus 1.9) were necessary using chromID versus conventional media. Notably, antimicrobial susceptibility testing demonstrated good overall agreement (97.4%) between the chromID and conventional media for all antibiotics tested. chromID CPS Elite is accurate for uropathogen identification, reduces consumable usage, and may expedite the identification of E. coli in clinical specimens

    Frequency of instrument, environment, and laboratory technologist contamination during routine diagnostic testing of infectious specimens

    Get PDF
    ABSTRACT Laboratory testing to support the care of patients with highly infectious diseases may pose a risk for laboratory workers. However, data on the risk of virus transmission during routine laboratory testing conducted using standard personal protective equipment (PPE) are sparse. Our objective was to measure laboratory contamination during routine analysis of patient specimens. Remnant specimens were spiked with the nonpathogenic bacteriophage MS2 at 1.0 × 10 7 PFU/ml, and contamination was assessed using reverse transcriptase PCR (RT-PCR) for MS2. Specimen containers were exteriorly coated with a fluorescent powder to enable the visualization of gross contamination using UV light. Testing was performed by two experienced laboratory technologists using standard laboratory PPE and sample-to-answer instrumentation. Fluorescence was noted on the gloves, bare hands, and laboratory coat cuffs of the laboratory technologist in 36/36 (100%), 13/36 (36%), and 4/36 (11%) tests performed, respectively. Fluorescence was observed in the biosafety cabinet (BSC) in 8/36 (22%) tests, on test cartridges/devices in 14/32 (44%) tests, and on testing accessory items in 29/32 (91%) tests. Fluorescence was not observed on or in laboratory instrumentation or adjacent surfaces. In contrast to fluorescence detection, MS2 detection was infrequent (3/286 instances [1%]) and occurred during test setup for the FilmArray instrument and on FilmArray accessory equipment. The information from this study may provide opportunities for the improvement of clinical laboratory safety practices so as to reduce the risk of pathogen transmission to laboratory workers. </jats:p

    Temperatures achieved in human and canine neocortex during intraoperative passive or active focal cooling

    Get PDF
    Focal cortical cooling inhibits seizures and prevents acquired epileptogenesis in rodents. To investigate the potential clinical utility of this treatment modality, we examined the thermal characteristics of canine and human brain undergoing active and passive surface cooling in intraoperative settings. Four patients with intractable epilepsy were treated in a standard manner. Before the resection of a neocortical epileptogenic focus, multiple intraoperative studies of active (custom-made cooled irrigation-perfused grid) and passive (stainless steel probe) cooling were performed. We also actively cooled the neocortices of two dogs with perfused grids implanted for 2 hours. Focal surface cooling of the human brain causes predictable depth-dependent cooling of the underlying brain tissue. Cooling of 0.6–2°C was achieved both actively and passively to a depth of 10–15 mm from the cortical surface. The perfused grid permitted comparable and persistent cooling of canine neocortex when the craniotomy was closed. Thus, the human cortex can easily be cooled with the use of simple devices such as a cooling grid or a small passive probe. These techniques provide pilot data for the design of a permanently implantable device to control intractable epilepsy
    corecore