384 research outputs found
Gaseous Dark Matter Detectors
Dark Matter detectors with directional sensitivity have the potential of
yielding an unambiguous positive observation of WIMPs as well as discriminating
between galactic Dark Matter halo models. In this article, we introduce the
motivation for directional detectors, discuss the experimental techniques that
make directional detection possible, and review the status of the experimental
effort in this field.Comment: 19 pages, review on gaseous directional dark matter detectors
submitted to New Journal of Physic
New FOCUS results on charm mixing and CP violation
We present a summary of recent results on CP violation and mixing in the
charm quark sector based on a high statistics sample collected by
photoproduction experiment FOCUS (E831 at Fermilab). We have measured the
difference in lifetimes for the decays: and . This translates into a measurement of the mixing parameter in
the \d0d0 system, under the assumptions that is an equal mixture of
CP odd and CP even eigenstates, and CP violation is negligible in the neutral
charm meson system. We verified the latter assumption by searching for a CP
violating asymmetry in the Cabibbo suppressed decay modes , and . We show preliminary
results on a measurement of the branching ratio .Comment: 9 pages, 6 figures, requires espcrc2.sty. Presented by S.Bianco at
CPConf2000, September 2000, Ferrara (Italy). In this revision, fixed several
stylistic flaws, add two significant references, fixed a typo in Tab.
Search for CP Violation in the decays D+ -> K_S pi+ and D+ -> K_S K+
A high statistics sample of photo-produced charm from the FOCUS(E831)
experiment at Fermilab has been used to search for direct CP violation in the
decays D+->K_S pi+ and D+ -> K_S K+. We have measured the following asymmetry
parameters relative to D+->K-pi+pi+: A_CP(K_S pi+) = (-1.6 +/- 1.5 +/- 0.9)%,
A_CP(K_S K+) = (+6.9 +/- 6.0 +/- 1.5)% and A_CP(K_S K+) = (+7.1 +/- 6.1 +/-
1.2)% relative to D+->K_S pi+. The first errors quoted are statistical and the
second are systematic. We also measure the relative branching ratios:
\Gamma(D+->\bar{K0}pi+)/\Gamma(D+->K-pi+pi+) = (30.60 +/- 0.46 +/- 0.32)%,
\Gamma(D+->\bar{K0}K+)/\Gamma(D+->K-pi+pi+) = (6.04 +/- 0.35 +/- 0.30)% and
\Gamma(D+->\bar{K0}K+)/\Gamma(D+->\bar{K0}pi+) = (19.96 +/- 1.19 +/- 0.96)%.Comment: 4 pages, 3 figure
A Measurement of the Ds+ Lifetime
A high statistics measurement of the Ds+ lifetime from the Fermilab
fixed-target FOCUS photoproduction experiment is presented. We describe the
analysis of the two decay modes, Ds+ -> phi(1020)pi+ and Ds+ ->
\bar{K}*(892)0K+, used for the measurement. The measured lifetime is 507.4 +/-
5.5 (stat.) +/- 5.1 (syst.) fs using 8961 +/- 105 Ds+ -> phi(1020)pi+ and 4680
+/- 90 Ds+ -> \bar{K}*(892)0K+ decays. This is a significant improvement over
the present world average.Comment: 5 pages, 3 figures, 2 tables, submitted to PR
Search for CP violation in D0 and D+ decays
A high statistics sample of photoproduced charm particles from the FOCUS
(E831) experiment at Fermilab has been used to search for CP violation in the
Cabibbo suppressed decay modes D+ to K-K+pi+, D0 to K-K+ and D0 to pi-pi+. We
have measured the following CP asymmetry parameters: A_CP(K-K+pi+) = +0.006 +/-
0.011 +/- 0.005, A_CP(K-K+) = -0.001 +/- 0.022 +/- 0.015 and A_CP(pi-pi+) =
+0.048 +/- 0.039 +/- 0.025 where the first error is statistical and the second
error is systematic. These asymmetries are consistent with zero with smaller
errors than previous measurements.Comment: 12 pages, 4 figure
Expression of Regulatory Platelet MicroRNAs in Patients with Sickle Cell Disease
Background: Increased platelet activation in sickle cell disease (SCD) contributes to a state of hypercoagulability and confers a risk of thromboembolic complications. The role for post-transcriptional regulation of the platelet transcriptome by microRNAs (miRNAs) in SCD has not been previously explored. This is the first study to determine whether platelets from SCD exhibit an altered miRNA expression profile. Methods and Findings: We analyzed the expression of miRNAs isolated from platelets from a primary cohort (SCD = 19, controls = 10) and a validation cohort (SCD = 7, controls = 7) by hybridizing to the Agilent miRNA microarrays. A dramatic difference in miRNA expression profiles between patients and controls was noted in both cohorts separately. A total of 40 differentially expressed platelet miRNAs were identified as common in both cohorts (p-value 0.05, fold change>2) with 24 miRNAs downregulated. Interestingly, 14 of the 24 downregulated miRNAs were members of three families - miR-329, miR-376 and miR-154 - which localized to the epigenetically regulated, maternally imprinted chromosome 14q32 region. We validated the downregulated miRNAs, miR-376a and miR-409-3p, and an upregulated miR-1225-3p using qRT-PCR. Over-expression of the miR-1225-3p in the Meg01 cells was followed by mRNA expression profiling to identify mRNA targets. This resulted in significant transcriptional repression of 1605 transcripts. A combinatorial approach using Meg01 mRNA expression profiles following miR-1225-3p overexpression, a computational prediction analysis of miRNA target sequences and a previously published set of differentially expressed platelet transcripts from SCD patients, identified three novel platelet mRNA targets: PBXIP1, PLAGL2 and PHF20L1. Conclusions: We have identified significant differences in functionally active platelet miRNAs in patients with SCD as compared to controls. These data provide an important inventory of differentially expressed miRNAs in SCD patients and an experimental framework for future studies of miRNAs as regulators of biological pathways in platelets. © 2013 Jain et al
A Study of D0 --> K0(S) K0(S) X Decay Channels
Using data from the FOCUS experiment (FNAL-E831), we report on the decay of
mesons into final states containing more than one . We present
evidence for two Cabibbo favored decay modes, and
, and measure their combined branching fraction
relative to to be = 0.0106
0.0019 0.0010. Further, we report new measurements of
=
0.0179 0.0027 0.0026, = 0.0144 0.0032 0.0016,
and = 0.0208 0.0035 0.0021 where the first error is
statistical and the second is systematic.Comment: 11 pages, 3 figures, typos correcte
Study of Cabibbo Suppressed Decays of the Ds Charmed-Strange Meson involving a KS
We study the decay of Ds meson into final states involving a Ks and report
the discovery of Cabibbo suppressed decay modes Ds -> Kspi-pi+pi+ (179 +/- 36
events) and Ds -> Kspi+ (113 +/-26 events). The branching ratios for the new
modes are Gamma(Ds -> Kspi-pi+pi+)/Gamma(Ds -> KsK-pi+pi+) = 0.18 +/- 0.04 +/-
0.05 and Gamma(Ds -> Kspi+)/Gamma(Ds -> KsK+) = 0.104 +/- 0.024 +/- 0.013.Comment: 11 pages, 6 figure
Dalitz plot analysis of D_s+ and D+ decay to pi+pi-pi+ using the K-matrix formalism
FOCUS results from Dalitz plot analysis of D_s+ and D+ to pi+pi-pi+ are
presented. The K-matrix formalism is applied to charm decays for the first time
to fully exploit the already existing knowledge coming from the light-meson
spectroscopy experiments. In particular all the measured dynamics of the S-wave
pipi scattering, characterized by broad/overlapping resonances and large
non-resonant background, can be properly included. This paper studies the
extent to which the K-matrix approach is able to reproduce the observed Dalitz
plot and thus help us to understand the underlying dynamics. The results are
discussed, along with their possible implications on the controversial nature
of the sigma meson.Comment: To be submitted to Phys.Lett.B A misprint corrected in formula
Search for CP violation in D0 and D+ decays
A high statistics sample of photoproduced charm particles from the FOCUS
(E831) experiment at Fermilab has been used to search for CP violation in the
Cabibbo suppressed decay modes D+ to K-K+pi+, D0 to K-K+ and D0 to pi-pi+. We
have measured the following CP asymmetry parameters: A_CP(K-K+pi+) = +0.006 +/-
0.011 +/- 0.005, A_CP(K-K+) = -0.001 +/- 0.022 +/- 0.015 and A_CP(pi-pi+) =
+0.048 +/- 0.039 +/- 0.025 where the first error is statistical and the second
error is systematic. These asymmetries are consistent with zero with smaller
errors than previous measurements.Comment: 12 pages, 4 figure
- …
