262 research outputs found
Slower is not always better: Response-time evidence clarifies the limited role of miserly information processing in the Cognitive Reflection Test
We report a study examining the role of `cognitive miserliness' as a determinant of poor performance on the standard three-item Cognitive Reflection Test (CRT). The cognitive miserliness hypothesis proposes that people often respond incorrectly on CRT items because of an unwillingness to go beyond default, heuristic processing and invest time and effort in analytic, reflective processing. Our analysis (N = 391) focused on people's response times to CRT items to determine whether predicted associations are evident between miserly thinking and the generation of incorrect, intuitive answers. Evidence indicated only a weak correlation between CRT response times and accuracy. Item-level analyses also failed to demonstrate predicted response time differences between correct analytic and incorrect intuitive answers for two of the three CRT items. We question whether participants who give incorrect intuitive answers on the CRT can legitimately be termed cognitive misers and whether the three CRT items measure the same general construct
Wearable robotic exoskeleton for overground gait training in sub-acute and chronic hemiparetic stroke patients: preliminary results
BACKGROUND: Recovery of therapeutic or functional ambulatory capacity in post-stroke patients is a primary goal of rehabilitation. Wearable powered exoskeletons allow patients with gait dysfunctions to perform over-ground gait training, even immediately after the acute event.AIM: To investigate the feasibility and the clinical effects of an over-ground walking training with a wearable powered exoskeleton in sub-acute and chronic stroke patients.DESIGN: Prospective, pilot pre-post, open label, non-randomized experimental study.SETTING: A single neurological rehabilitation center for inpatients and outpatients.POPULATION: Twenty-three post-stroke patients were enrolled: 12 sub-acute (mean age: 43.8\ub113.3 years, 5 male and 7 female, 7 right hemiparesis and 5 left hemiparesis) and 11 chronic (mean age: 55.5\ub115.9 years, 7 male and 4 female, 4 right hemiparesis and 7 left hemiparesis) patients.METHODS: Patients underwent 12 sessions (60 min/session, 3 times/week) of walking rehabilitation training using Ekso\u2122, a wearable bionic suit that enables individuals with lower extremity disabilities and minimal forearm strength to stand up, sit down and walk over a flat hard surface with a full weight-bearing reciprocal gait. Clinical evaluations were performed at the beginning of the training period (t0), after 6 sessions (t1) and after 12 sessions (t2) and were based on the Ashworth scale, Motricity Index, Trunk Control Test, Functional Ambulation Scale, 10-Meter Walking Test, 6-Minute Walking Test, and Walking Handicap Scale. Wilcoxon's test (P<0.05) was used to detect significant changes.RESULTS: Statistically significant improvements were observed at the three assessment periods for both groups in Motricity Index, Functional Ambulation Scale, 10-meter walking test, and 6-minute walking test. Sub-acute patients achieved statistically significant improvement in Trunk Control Test and Walking Handicap Scale at t0-t2. Sub-acute and chronic patient did not achieve significant improvement in Ashworth scale at t0-t2.CONCLUSIONS: Twelve sessions of over-ground gait training using a powered wearable robotic exoskeleton improved ambulatory functions in sub-acute and chronic post-stroke patients. Large, randomized multicenter studies are needed to confirm these preliminary data.CLINICAL REHABILITATION IMPACT: To plan a completely new individual tailored robotic rehabilitation strategy after stroke, including task-oriented over-ground gait training
The ASTAROTH Project: enhanced low-energy sensitivity to Dark Matter annual modulation
ASTAROTH is a novel R&D project which aims at improving the physics reach of future direct dark matter detection experiments based on NaI(Tl) scintillating crystals. There is a strong need to test the long standing DAMA positive observation of an annual modulation that could be due to Dark Matter (DM), with the same target material and in a model independent way. ASTAROTH aim is the enhancement of the sensitivity to the annual modulation signal, compared with present technology, by lowering the detection energy threshold in order to observe sub-keV recoils for the first time. This can be achieved by reading the scintillation light from the NaI(Tl) crystals with arrays of Silicon PhotoMultipliers (SiPM), and placing the detectors in a cryogenic environment. SiPMs feature lower dark noise than Photomultiplier Tubes (PMTs) at T < 150 K and allow for higher light collection. The cooling medium is liquid Argon, as it is an excellent scintillator that can be instrumented to act as a veto against several backgrounds.
Here we present the status of the ASTAROTH project, introducing the innovative design of the detector chamber that will be used for the demonstration of the technology. Then, we will show the preliminary results of our first ever measurements performed on a single NaI(Tl) crystal read out by one SiPM array in a cryogenic set-up cooled with liquid nitrogen
A Pixel Read-Out Front-End in 28 nm CMOS with Time and Space Resolution
Future high luminosity colliders will require front-end electronics with unprecedented performance, both in space and time resolution (tens of micrometers and tens of picoseconds) and in radiation hardness (tens of megagray). Moreover, the high number of events will generate an enormous quantity of data (some terabits per second), and the limited bandwidth requires to perform data selection as close as possible to the front-end stage, to reduce the amount of data transmitted and stored for off-line analysis.The TimeSpOT (TIME and SPace real-time Operating Tracker) project, funded by INFN, is developing a complete demonstrator of a tracking device including all the features needed for future high luminosity experiments.In this presentation, we describe the first prototype of the readout electronics in 28 nm CMOS technology. The modules of the front-end circuitry have been designed and integrated in a test chip, which will allow us to characterize each block separately, and to connect them in a processing chain to evaluate the overall performance
Characterization and tests of different Mach-Zehnder silicon photonic modulator configurations
We designed and produced an integrated silicon photonic circuit, in a single chip with IHP SG25H4_EPIC 0.25 μm technology. A Mach-Zehnder interferometer with an alternative shape for better integration, together with a standard-shape Mach-Zehnder interferometer have been realized. In this work, preliminary results of comparative performance measurements between the two Mach-Zehnder interferometer are shown
Il Forum. Sulla vaccinazione in tempo di Covid-19
DOMANDE
1) Ritiene che l’obbligo vaccinale introdotto dal d.l. 44/2021 per gli esercenti le professioni sanitarie e gli operatori di interesse sanitario trovi una propria giustificazione sul piano costituzionale? Ritiene altresì che il suddetto obbligo vaccinale – anche sulla scorta della recente giurisprudenza costituzionale – possa (o debba) essere esteso alla generalità della popolazione in caso di una insufficiente adesione su base volontaria?
2) Come valuta le differenze di regime tra Regioni (ognuna apre a categorie diverse in momenti diversi, con sistemi di prenotazione diversi, procedendo quindi a velocità diverse)?
3) Come valuta la ventilata connessione tra l’adempimento vaccinale e l’esercizio di alcune libertà costituzionali (in primis, quella di circolazione)? Ritiene che specifici “titoli” di autorizzazione agli spostamenti (si pensi ai c.d. Green pass nazionali o europei) possano essere subordinati all’adesione ad una campagna vaccinale non obbligatoria?
4) Come giudica il ruolo svolto dalle Istituzioni dell’Unione Europea nella contrattazione “a nome di tutti gli Stati membri” con le aziende produttrici dei vaccini? Ha funzionato a suo giudizio il meccanismo di solidarietà? Ritiene che il ruolo svolto dalle Istituzioni dell’Unione Europea abbia garantito una più equa distribuzione dei vaccini tra gli Stati membri (soprattutto per quelli a minore capacità produttiva), consentendo una campagna vaccinale a velocità sostanzialmente uniforme, ovvero ritiene che esse abbiano costituito un freno alle singole campagne nazionali che, con maggiore autonomia, avrebbero potuto svolgersi in tempi molto più rapidi
Does the cognitive reflection test measure cognitive reflection? A mathematical modeling approach
We used a mathematical modeling approach, based on a sample of 2,019 participants, to better understand what the cognitive reflection test (CRT; Frederick In Journal of Economic Perspectives, 19, 25–42, 2005) measures. This test, which is typically completed in less than 10 min, contains three problems and aims to measure the ability or disposition to resist reporting the response that first comes to mind. However, since the test contains three mathematically based problems, it is possible that the test only measures mathematical abilities, and not cognitive reflection. We found that the models that included an inhibition parameter (i.e., the probability of inhibiting an intuitive response), as well as a mathematical parameter (i.e., the probability of using an adequate mathematical procedure), fitted the data better than a model that only included a mathematical parameter. We also found that the inhibition parameter in males is best explained by both rational thinking ability and the disposition toward actively open-minded thinking, whereas in females this parameter was better explained by rational thinking only. With these findings, this study contributes to the understanding of the processes involved in solving the CRT, and will be particularly useful for researchers who are considering using this test in their research
Retrograde movements determine effective stem cell numbers in the intestine
The morphology and functionality of the epithelial lining differ along the intestinal tract, but tissue renewal at all sites is driven by stem cells at the base of crypts(1-3). Whether stem cell numbers and behaviour vary at different sites is unknown. Here we show using intravital microscopy that, despite similarities in the number and distribution of proliferative cells with an Lgr5 signature in mice, small intestinal crypts contain twice as many effective stem cells as large intestinal crypts. We find that, although passively displaced by a conveyor-belt-like upward movement, small intestinal cells positioned away from the crypt base can function as long-term effective stem cells owing to Wnt-dependent retrograde cellular movement. By contrast, the near absence of retrograde movement in the large intestine restricts cell repositioning, leading to a reduction in effective stem cell number. Moreover, after suppression of the retrograde movement in the small intestine, the number of effective stem cells is reduced, and the rate of monoclonal conversion of crypts is accelerated. Together, these results show that the number of effective stem cells is determined by active retrograde movement, revealing a new channel of stem cell regulation that can be experimentally and pharmacologically manipulated.Peer reviewe
HASPIDE: a project for the development of hydrogenated amorphous silicon radiation sensors on a flexible substrate
Hydrogenated amorphous silicon (a-Si:H) is a material with a very good radiation hardness and with the possibility of deposition on flexible substrates like Polyimide (PI). Exploiting these properties, the HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project has the goal of developing a-Si:H detectors on flexible substrates for beam dosimetry and profile monitoring, neutron detection and space experiments. The detectors for this experiment will be developed in two different structures: the n -i -p diode structure, which has been used up to now for the construction of the planar a-Si:H detectors, and the recently developed charge selective contact structure. In the latter the doped layers (n or p) are replaced with charge selective materials namely electron-selective conductive metal-oxides (TiO2 or Al:ZnO) and hole-selective conductive metal oxides (MoOx). In this paper preliminary data on the capabilities of these detectors to measure X-ray and electron fluxes will be presented. In particular, the linearity, the sensitivity, the stability and dark current in various conditions will be discussed
COLLABORATIVE AGENCY IN EDUCATIONAL MANAGEMENT: A JOINT OBJECT FOR SCHOOL AND COMMUNITY TRANSFORMATION
- …
