    Radiation Damage and Recovery Properties of Common Plastics PEN (Polyethylene Naphthalate) and PET (Polyethylene Terephthalate) Using a 137Cs Gamma Ray Source Up To 1 MRad and 10 MRad

    Full text link
    Polyethylene naphthalate (PEN) and polyethylene teraphthalate (PET) are cheap and common polyester plastics used throughout the world in the manufacturing of bottled drinks, containers for foodstuffs, and fibers used in clothing. These plastics are also known organic scintillators with very good scintillation properties. As particle physics experiments increase in energy and particle flux density, so does radiation exposure to detector materials. It is therefore important that scintillators be tested for radiation tolerance at these generally unheard of doses. We tested samples of PEN and PET using laser stimulated emission on separate tiles exposed to 1 MRad and 10 MRad gamma rays with a 137Cs source. PEN exposed to 1 MRad and 10 MRad emit 71.4% and 46.7% of the light of an undamaged tile, respectively, and maximally recover to 85.9% and 79.5% after 5 and 9 days, respectively. PET exposed to 1 MRad and 10 MRad emit 35.0% and 12.2% light, respectively, and maximally recover to 93.5% and 80.0% after 22 and 60 days, respectively

    Characterization of photomultiplier tubes in a novel operation mode for Secondary Emission Ionization Calorimetry

    Full text link
    Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The different operation modes used in these tests were developed by modifying the conventional PMT bias circuit. These modifications were simple changes to the arrangement of the voltage dividers of the baseboard circuits. The PMTs with modified bases, referred to as operating in SE mode, are used as an SE detector module in an SE calorimeter prototype, and placed between absorber materials (Fe, Cu, Pb, W, etc.). Here, the technical design of different operation modes, as well as the characterization measurements of both SE modes and the conventional PMT mode are reported

    Physics at Very Small Angles with CASTOR at CMS

    Get PDF
    CASTOR is a small (56 cm diameter) quartz-tungsten Cerenkov calorimeter covering the small angles 0.2-0.6 deg (5.2<="eta"<=6.4) in CMS, a major experiment at the LHC. Particularly with heavy-ion reactions a substantial fraction of the total reaction energy goes into this large "eta" region. CASTOR will function as a part of CMS and also as an independent detector to search for special types of events in the far-forward region. It is divided into 16 azimuthal sectors, each with 18 longitudinal segments to allow identification of particles by their energy-loss profiles. The most forward segments are smaller to better characterize electromagnetic events

    Status of Zero Degree Calorimeter for CMS Experiment

    Get PDF
    The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling calorimeters using tungsten and quartz fibers have been chosen for the energy measurements. An overview of the ZDC is presented along with a current status of calorimeter's preparation for Day 1 of LHC.Comment: 8 pages, 5 figures, 1 table, to appear in the proceedings of CALOR06, June 5-9, 2006 Chicago, US

    An instrument to measure fast gas phase radical kinetics at hight temperatures and pressures

    Get PDF
    Fast radical reactions are central to the chemistry of planetary atmospheres and combustion systems. Laser-induced fluorescence is a highly sensitive and selective technique that can be used to monitor a number of radical species in kinetics experiments, but is typically limited to low pressure systems owing to quenching of fluorescent states at higher pressures. The design and characterisation of an instrument is reported using laser-induced fluorescence detection to monitor fast radical kinetics (up to 25,000 s-1) at high temperatures and pressures by sampling from a high pressure reaction region to a low pressure detection region. Kinetics have been characterised at temperatures reaching 740 K and pressures up to 2 atm, with expected maximum operational conditions of up to ~ 900 K and ~ 5 atm. The distance between the point of sampling from the high pressure region and the point of probing within the low pressure region is critical to the measurement of fast kinetics. The instrumentation described in this work can be applied to the measurement of kinetics relevant to atmospheric and combustion chemistry

    A new method for atmospheric detection of the CH3O2 radical

    Get PDF
    A new method for measurement of the methyl peroxy (CH3O2) radical has been developed using the conversion of CH3O2 into CH3O by excess NO with subsequent detection of CH3O by fluorescence assay by gas expansion (FAGE) with laser excitation at ca. 298 nm. The method can also directly detect CH3O, when no nitric oxide is added. Laboratory calibrations were performed to characterise the FAGE instrument sensitivity using the conventional radical source employed in OH calibration with conversion of a known concentration of OH into CH3O2 via reaction with CH4 in the presence of O2. Detection limits of 3.8 × 108 and 3.0 × 108 molecule cm−3 were determined for CH3O2 and CH3O respectively for a signal-to-noise ratio of 2 and 5 min averaging time. Averaging over 1 h reduces the detection limit for CH3O2 to 1.1 × 108 molecule cm−3, which is comparable to atmospheric concentrations. The kinetics of the second-order decay of CH3O2 via its self-reaction were observed in HIRAC (Highly Instrumented Reactor for Atmospheric Chemistry) at 295 K and 1 bar and used as an alternative method of calibration to obtain a calibration constant with overlapping error limits at the 1σ level with the result of the conventional method of calibration. The overall uncertainties of the two methods of calibrations are similar – 15 % for the kinetic method and 17 % for the conventional method – and are discussed in detail. The capability to quantitatively measure CH3O in chamber experiments is demonstrated via observation in HIRAC of CH3O formed as a product of the CH3O2 self-reaction

    Status of zero degree calorimeter for CMS experiment

    Get PDF
    The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling calorimeters using tungsten and quartz fibers have been chosen for the energy measurements. An overview of the ZDC is presented along with a current status of calorimeter's preparation for Day 1 of LHC

    Studies of the Response of the Prototype CMS Hadron Calorimeter, Including Magnetic Field Effects, to Pion, Electron, and Muon Beams

    Get PDF
    We report on the response of a prototype CMS hadron calorimeter module to charged particle beams of pions, muons, and electrons with momenta up to 375 GeV/c. The data were taken at the H2 and H4 beamlines at CERN in 1995 and 1996. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. The effects of a magnetic field of up to 3 Tesla on the response of the calorimeter to muons, electrons, and pions are presented, and the effects of an upstream lead tungstate crystal electromagnetic calorimeter on the linearity and energy resolution of the combined calorimetric system to hadrons are evaluated. The results are compared with Monte Carlo simulations and are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation.Comment: 89 pages, 41 figures, to be published in NIM, corresponding author: P de Barbaro, [email protected]

    pi-NN Coupling Constants from NN Elastic Data between 210 and 800 Mev

    Full text link
    High partial waves for pppp and npnp elastic scattering are examined critically from 210 to 800 MeV. Non-OPE contributions are compared with predictions from theory. There are some discrepancies, but sufficient agreement that values of the πNN\pi NN coupling constants g02g_0^2 for π0\pi ^0 exchange and gc2g^2_{c} for charged π\pi exchange can be derived. Results are g02=13.91±0.13±0.07g^2_0 = 13.91 \pm 0.13 \pm 0.07 and gc2=13.69±0.15±0.24g^2_c = 13.69 \pm 0.15 \pm 0.24, where the first error is statistical and the second is an estimate of the likely systematic error, arising mostly from uncertainties in the normalisation of total cross sections and dσ/dΩd\sigma/d\Omega.Comment: 21 pages of LaTeX, UI-NTH-940