1,991 research outputs found

    Parameterization Effects in the analysis of AMI Sunyaev-Zel'dovich Observations

    Get PDF
    Most Sunyaev--Zel'dovich (SZ) and X-ray analyses of galaxy clusters try to constrain the cluster total mass and/or gas mass using parameterised models and assumptions of spherical symmetry and hydrostatic equilibrium. By numerically exploring the probability distributions of the cluster parameters given the simulated interferometric SZ data in the context of Bayesian methods, and assuming a beta-model for the electron number density we investigate the capability of this model and analysis to return the simulated cluster input quantities via three rameterisations. In parameterisation I we assume that the T is an input parameter. We find that parameterisation I can hardly constrain the cluster parameters. We then investigate parameterisations II and III in which fg(r200) replaces temperature as a main variable. In parameterisation II we relate M_T(r200) and T assuming hydrostatic equilibrium. We find that parameterisation II can constrain the cluster physical parameters but the temperature estimate is biased low. In parameterisation III, the virial theorem replaces the hydrostatic equilibrium assumption. We find that parameterisation III results in unbiased estimates of the cluster properties. We generate a second simulated cluster using a generalised NFW (GNFW) pressure profile and analyse it with an entropy based model to take into account the temperature gradient in our analysis and improve the cluster gas density distribution. This model also constrains the cluster physical parameters and the results show a radial decline in the gas temperature as expected. The mean cluster total mass estimates are also within 1 sigma from the simulated cluster true values. However, we find that for at least interferometric SZ analysis in practice at the present time, there is no differences in the AMI visibilities between the two models. This may of course change as the instruments improve.Comment: 19 pages, 13 tables, 24 figure

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data
    corecore