361 research outputs found
Impact Factor: outdated artefact or stepping-stone to journal certification?
A review of Garfield's journal impact factor and its specific implementation
as the Thomson Reuters Impact Factor reveals several weaknesses in this
commonly-used indicator of journal standing. Key limitations include the
mismatch between citing and cited documents, the deceptive display of three
decimals that belies the real precision, and the absence of confidence
intervals. These are minor issues that are easily amended and should be
corrected, but more substantive improvements are needed. There are indications
that the scientific community seeks and needs better certification of journal
procedures to improve the quality of published science. Comprehensive
certification of editorial and review procedures could help ensure adequate
procedures to detect duplicate and fraudulent submissions.Comment: 25 pages, 12 figures, 6 table
The Evolution of Compact Binary Star Systems
We review the formation and evolution of compact binary stars consisting of
white dwarfs (WDs), neutron stars (NSs), and black holes (BHs). Binary NSs and
BHs are thought to be the primary astrophysical sources of gravitational waves
(GWs) within the frequency band of ground-based detectors, while compact
binaries of WDs are important sources of GWs at lower frequencies to be covered
by space interferometers (LISA). Major uncertainties in the current
understanding of properties of NSs and BHs most relevant to the GW studies are
discussed, including the treatment of the natal kicks which compact stellar
remnants acquire during the core collapse of massive stars and the common
envelope phase of binary evolution. We discuss the coalescence rates of binary
NSs and BHs and prospects for their detections, the formation and evolution of
binary WDs and their observational manifestations. Special attention is given
to AM CVn-stars -- compact binaries in which the Roche lobe is filled by
another WD or a low-mass partially degenerate helium-star, as these stars are
thought to be the best LISA verification binary GW sources.Comment: 105 pages, 18 figure
Chelators in Iron and Copper Toxicity
Purpose of Review Chelation therapy is used for diseases causing an imbalance of iron levels (for example haemochromatosis and thalassaemia) or copper levels (for example Menkes’ and Wilson’s diseases). Currently, most pharmaceutical chelators are relatively simple but often have side effects. Some have been taken off the market. This review attempts to find theory and knowledge required to design or find better chelators. Recent Findings Recent research attempting to understand the biological mechanisms of protection against iron and copper toxicity is reviewed. Understanding of molecular mechanisms behind normal iron/copper regulation may lead to the design of more sophisticated chelators. The theory of metal ion toxicity explains why some chelators, such as EDTA, which chelate metal ions in a way which exposes the ion to the surrounding environment are shown to be unsuitable except as a means of killing cancer cells. The Lewis theory of acids and bases suggests which amino acids favour the attachment of the hard/intermediate ions Fe2+, Fe3+, Cu2+ and soft ion Cu+. Non-polar amino acids will chelate the ion in a position not in contact with the surrounding cellular environment. The conclusion is that only the soft ion binding cysteine and methionine appear as suitable chelators. Clearly, nature has developed proteins which are less restricted. Recent research on naturally produced chelators such as siderophores and phytochemicals show some promise as pharmaceuticals. Summary Although an understanding of natural mechanisms of Fe/Cu regulation continues to increase, the pharmaceutical chelators for metal overload diseases remain simple non-protein molecules. Natural and synthetic alternatives have been studied but require further research before being accepted
Measurement of triple gauge-boson couplings at 172 GeV
The triple gauge-boson couplings, Awp, Aw and Abp, have been measured using 34 semileptonically and 54 hadronically decaying WW candidate events. The events were selected in the data recorded during 1996 with the ALEPH detector at 172 GeV, corresponding to an integrated luminosity of 10.65 pb^-1. The triple gauge-boson couplings have been measured using optimal observables constructed from kinematic information of WW events. The results are in agreement with the Standard Model expectation
Determination of sin2 θeff w using jet charge measurements in hadronic Z decays
The electroweak mixing angle is determined with high precision from measurements of the mean difference between forward and backward hemisphere charges in hadronic decays of the Z. A data sample of 2.5 million hadronic Z decays recorded over the period 1990 to 1994 in the ALEPH detector at LEP is used. The mean charge separation between event hemispheres containing the original quark and antiquark is measured for bb̄ and cc̄ events in subsamples selected by their long lifetimes or using fast D*'s. The corresponding average charge separation for light quarks is measured in an inclusive sample from the anticorrelation between charges of opposite hemispheres and agrees with predictions of hadronisation models with a precision of 2%. It is shown that differences between light quark charge separations and the measured average can be determined using hadronisation models, with systematic uncertainties constrained by measurements of inclusive production of kaons, protons and A's. The separations are used to measure the electroweak mixing angle precisely as sin2 θeff w = 0.2322 ± 0.0008(exp. stat.) ±0.0007(exp. syst.) ± 0.0008(sep.). The first two errors are due to purely experimental sources whereas the third stems from uncertainties in the quark charge separations
Aspiration of parenteral nutrition – a previously unreported complication of central venous access in an infant: a case report
Introduction: The insertion of percutaneous central venous catheters is a common procedure in neonatal intensive care nurseries. Placement of the catheter tip in a large central vein is most desirable. Occasionally, due to difficult venous access, catheter tips are left in places that are less than ideal. Case presentation: A female infant with a complicated gastroschisis developed signs of short bowel syndrome post surgery. She was treated with a combination of parenteral nutrition and enteral feeds. A central venous line was inserted through a scalp vein. The tip was noted to be in a vessel at the level of the mandible. She subsequently became unwell with large milky pharyngeal aspirates and episodes of bradycardia. Chest radiography revealed aspiration. The central venous line was removed because of presumed extravasation. This is the first reported case of parenteral nutrition extravasation into the pharynx causing aspiration in an infant. Conclusion: This complication may have been prevented by recognising that the tip of the catheter was not correctly placed. When catheters are in unusual positions it may be useful to obtain a second radiograph from a different angle or an ultrasound scan to confirm the positioning of the catheter tip
Aspiration of parenteral nutrition – a previously unreported complication of central venous access in an infant: a case report
Introduction: The insertion of percutaneous central venous catheters is a common procedure in neonatal intensive care nurseries. Placement of the catheter tip in a large central vein is most desirable. Occasionally, due to difficult venous access, catheter tips are left in places that are less than ideal. Case presentation: A female infant with a complicated gastroschisis developed signs of short bowel syndrome post surgery. She was treated with a combination of parenteral nutrition and enteral feeds. A central venous line was inserted through a scalp vein. The tip was noted to be in a vessel at the level of the mandible. She subsequently became unwell with large milky pharyngeal aspirates and episodes of bradycardia. Chest radiography revealed aspiration. The central venous line was removed because of presumed extravasation. This is the first reported case of parenteral nutrition extravasation into the pharynx causing aspiration in an infant. Conclusion: This complication may have been prevented by recognising that the tip of the catheter was not correctly placed. When catheters are in unusual positions it may be useful to obtain a second radiograph from a different angle or an ultrasound scan to confirm the positioning of the catheter tip
Measurement of the W mass by direct reconstruction in collisions at 172 GeV
The mass of the W boson is obtained from reconstructed invariant mass distributions in W-pair events. The sample of W pairs is selected from 10.65~pb collected with the ALEPH detector at a mean centre-of-mass energy of 172.09 \GEV. The invariant mass distribution of simulated events are fitted to the experimental distributions and the following W masses are obtained: , , . The statistical errors are the expected errors for Monte Carlo samples of the same integrated luminosity as the data. The combination of these measurements gives:
Childhood solid tumours in relation to population mixing around the time of birth
In a retrospective cohort study of 673 787 live births in the Northern Region of England, 1975 - 1994, we investigated whether a higher level of population mixing around birth was a risk factor for solid tumours, by diagnostic group (Hodgkin's disease, brain and spinal tumours, neuroblastoma, other solid tumours), diagnosed during 1975-2001 under age 15 years. Logistic regression was used to relate risk to population mixing, based on (i) all movers and (ii) incomers from outside the region. Both ward and county district level analyses were performed. There was a decreased risk of brain and spinal tumours with increasing population mixing based on incomers from outside the region (OR for trend across three categories = 0.79, 95% CI: 0.66-0.95, P = 0.01 in the ward level analysis). Although this may be because of chance, it is consistent with a role of exposure to infection and immunological response in the aetiology of these tumours. For other tumour groups, there was no consistent evidence of an association between risk and population mixing
Current use of medical eponyms – a need for global uniformity in scientific publications
<p>Abstract</p> <p>Background</p> <p>Although eponyms are widely used in medicine, they arbitrarily alternate between the possessive and nonpossessive forms. As very little is known regarding extent and distribution of this variation, the present study was planned to assess current use of eponymous term taking "Down syndrome" and "Down's syndrome" as an example.</p> <p>Methods</p> <p>This study was carried out in two phases – first phase in 1998 and second phase in 2008. In the first phase, we manually searched the terms "Down syndrome" and "Down's syndrome" in the indexes of 70 medical books, and 46 medical journals. In second phase, we performed PubMed search with both the terms, followed by text-word search for the same.</p> <p>Results</p> <p>In the first phase, there was an overall tilt towards possessive form – 62(53.4%) "Down's syndrome" versus 54(46.6%) "Down syndrome." However, the American publications preferred the nonpossesive form when compared with their European counterpart (40/50 versus 14/66; P < 0.001). In the second phase, PubMed search showed, compared to "Down syndrome," term "Down's syndrome" yielded approximately 5% more articles. The text-word search of both forms between January 1970 and June 2008 showed a gradual shift from "Down's syndrome" to "Down syndrome," and over the last 20 years, the frequency of the former was approximately halved (33.7% versus 16.5%; P < 0.001). The abstracts having possessive form were mostly published from the European countries, while most American publications used nonpossesive form consistently.</p> <p>Conclusion</p> <p>Inconsistency in the use of medical eponyms remains a major problem in literature search. Because of linguistic simplicity and technical advantages, the nonpossessive form should be used uniformly worldwide.</p
- …
