1,667 research outputs found
Mass fluxes and isofluxes of methane (CH4) at a New Hampshire fen measured by a continuous wave quantum cascade laser spectrometer
We have developed a mid‐infrared continuous‐wave quantum cascade laser direct‐absorption spectrometer (QCLS) capable of high frequency (≥1 Hz) measurements of 12CH4 and 13CH4 isotopologues of methane (CH4) with in situ 1‐s RMS image precision of 1.5 ‰ and Allan‐minimum precision of 0.2 ‰. We deployed this QCLS in a well‐studied New Hampshire fen to compare measurements of CH4 isoflux by eddy covariance (EC) to Keeling regressions of data from automated flux chamber sampling. Mean CH4 fluxes of 6.5 ± 0.7 mg CH4 m−2 hr−1 over two days of EC sampling in July, 2009 were indistinguishable from mean autochamber CH4 fluxes (6.6 ± 0.8 mgCH4 m−2 hr−1) over the same period. Mean image composition of emitted CH4 calculated using EC isoflux methods was −71 ± 8 ‰ (95% C.I.) while Keeling regressions of 332 chamber closing events over 8 days yielded a corresponding value of −64.5 ± 0.8 ‰. Ebullitive fluxes, representing ∼10% of total CH4 fluxes at this site, were on average 1.2 ‰ enriched in 13C compared to diffusive fluxes. CH4 isoflux time series have the potential to improve process‐based understanding of methanogenesis, fully characterize source isotopic distributions, and serve as additional constraints for both regional and global CH4 modeling analysis
The UK clinical aptitude test and clinical course performance at Nottingham: a prospective cohort study
Background
The UK Clinical Aptitude Test (UKCAT) was introduced in 2006 as an additional tool for the selection of medical students. It tests mental ability in four distinct domains (Verbal Reasoning, Quantitative Reasoning, Abstract Reasoning, and Decision Analysis), and the results are available to students and admission panels in advance of the selection process. Our first study showed little evidence of any predictive validity for performance in the first two years of the Nottingham undergraduate course.
The study objective was to determine whether the UKCAT scores had any predictive value for the later parts of the course, largely delivered via clinical placements.
Methods
Students entering the course in 2007 and who had taken the UKCAT were asked for permission to use their anonymised data in research. The UKCAT scores were incorporated into a database with routine pre-admission socio-demographics and subsequent course performance data. Correlation analysis was followed by hierarchical multivariate linear regression.
Results
The original study group comprised 204/254 (80%) of the full entry cohort. With attrition over the five years of the course this fell to 185 (73%) by Year 5. The Verbal Reasoning score and the UKCAT Total score both demonstrated some univariate correlations with clinical knowledge marks, and slightly less with clinical skills. No parts of the UKCAT proved to be an independent predictor of clinical course marks, whereas prior attainment was a highly significant predictor (p <0.001).
Conclusions
This study of one cohort of Nottingham medical students showed that UKCAT scores at admission did not independently predict subsequent performance on the course. Whilst the test adds another dimension to the selection process, its fairness and validity in selecting promising students remains unproven, and requires wider investigation and debate by other schools
Recommended from our members
Simultaneous Measurements of Atmospheric HONO and NO2 via Absorption Spectroscopy using Tunable Mid-Infrared Continuous-wave Quantum Cascade Lasers
Nitrous acid (HONO) is important as a significant source of hydroxyl radical (OH) in the troposphere and as a potent indoor air pollutant. It is thought to be generated in both environments via heterogeneous reactions involving nitrogen dioxide . In order to enable fast-response HONO detection suitable for eddy-covariance flux measurements and to provide a direct method that avoids interferences associated with derivatization, we have developed a 2-channel tunable infrared laser differential absorption spectrometer (TILDAS) capable of simultaneous high-frequency measurements of HONO and NO2. Beams from two mid-infrared continuous-wave mode quantum cascade lasers (cw-QCLs) traverse separate 210 m paths through a multi-pass astigmatic sampling cell at reduced pressure for the direct detection of HONO and . The resulting one-second detection limits (S/N=3) are 300 and 30 ppt (pmol/mol) for HONO and , respectively. Our HONO quantification is based on revised line-strengths and peak positions for cis-HONO in the 6-micron spectral region that were derived from laboratory measurements. An essential component of ambient HONO measurements is the inlet system and we demonstrate that heated surfaces and reduced pressure minimize sampling artifacts.Earth and Planetary SciencesEngineering and Applied Science
Using Differential Item Functioning to evaluate potential bias in a high stakes postgraduate knowledge based assessment
BACKGROUND: Fairness is a critical component of defensible assessment. Candidates should perform according to ability without influence from background characteristics such as ethnicity or sex. However, performance differs by candidate background in many assessment environments. Many potential causes of such differences exist, and examinations must be routinely analysed to ensure they do not present inappropriate progression barriers for any candidate group. By analysing the individual questions of an examination through techniques such as Differential Item Functioning (DIF), we can test whether a subset of unfair questions explains group-level differences. Such items can then be revised or removed. METHODS: We used DIF to investigate fairness for 13,694 candidates sitting a major international summative postgraduate examination in internal medicine. We compared (a) ethnically white UK graduates against ethnically non-white UK graduates and (b) male UK graduates against female UK graduates. DIF was used to test 2773 questions across 14 sittings. RESULTS: Across 2773 questions eight (0.29%) showed notable DIF after correcting for multiple comparisons: seven medium effects and one large effect. Blinded analysis of these questions by a panel of clinician assessors identified no plausible explanations for the differences. These questions were removed from the question bank and we present them here to share knowledge of questions with DIF. These questions did not significantly impact the overall performance of the cohort. Group-level differences in performance between the groups we studied in this examination cannot be explained by a subset of unfair questions. CONCLUSIONS: DIF helps explore fairness in assessment at the question level. This is especially important in high-stakes assessment where a small number of unfair questions may adversely impact the passing rates of some groups. However, very few questions exhibited notable DIF so differences in passing rates for the groups we studied cannot be explained by unfairness at the question level
Measurement of Trace Water Vapor in a Carbon Dioxide Removal Assembly Product Stream
The International Space Station Carbon Dioxide Removal Assembly (CDRA) uses regenerable adsorption technology to remove carbon dioxide (COP) from cabin air. Product water vapor measurements from a CDRA test bed at the NASA Marshall Space Flight Center were made using a tunable infrared diode laser differential absorption spectrometer (TILDAS) provided by NASA Glenn Research Center. The TILDAS instrument exceeded all the test specifications, including sensitivity, dynamic range, time response, and unattended operation. During the COP desorption phase, water vapor concentrations as low as 5 ppmv were observed near the peak of CO2 evolution, rising to levels of approx. 40 ppmv at the end of a cycle. Periods of high water concentration (>100 ppmv) were detected and shown to be caused by an experimental artifact. Measured values of total water vapor evolved during a single desorption cycle were as low as 1 mg
RTAPS (Research and Technology for Aerospace Propulsion Systems): Simulation of Structural Loads within a Hybrid Gear Resulting From Loading at the Gear Teeth
This report investigates the practical usage of hybrid structures for rotorcraft gearing. The primary driver for utilizing hybrid structures for rotorcraft gearing is to reduce the drive system weight. The hybrid structure concept featured in this study for rotorcraft gearing consists of a metallic gear tooth-rim, a web section manufactured from composite materials, and a metallic hub. The metallic gear tooth-rim is manufactured from conventional gear steel alloys, such as AISI 9310. The gear tooth-rim attaches to the outer diameter of the web section made from composite materials. The inner diameter of the composite web can then attach to a metallic hub, completing the assembly. It is assumed that areas of the shafting or hub where rolling element bearings may ride must remain as gear steel alloys for this study
- …
