522 research outputs found

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Developments at Finisar AOC

    Get PDF
    ABSTRACT In 2007 Finisar completed the transfer of an entire epi and fab line from one facility to another. During this period, reliability models had to be re-validated and product continuity maintained. In this paper we describe the activities necessary to support such a transition, and we extend previously published VCSEL failure atlases

    Cost effectiveness of potential ART adherence monitoring interventions in sub-saharan Africa

    Get PDF
    Background Interventions based around objective measurement of adherence to antiretroviral drugs for HIV have potential to improve adherence and to enable differentiation of care such that clinical visits are reduced in those with high adherence. It would be useful to understand the approximate upper limit of cost that could be considered for such interventions of a given effectiveness in order to be cost effective. Such information can guide whether to implement an intervention in the light of a trial showing a certain effectiveness and cost. Methods An individual-based model, calibrated to Zimbabwe, which incorporates effects of adherence and resistance to antiretroviral therapy, was used to model the potential impact of adherence monitoring-based interventions on viral suppression, death rates, disability adjusted life years and costs. Potential component effects of the intervention were: enhanced average adherence when on ART, reduced risk of ART discontinuation, and reduced risk of resistance acquisition. We considered a situation in which viral load monitoring is not available and one in which it is. In the former case, it was assumed that care would be differentiated based on the adherence level, with fewer clinic visits in those demonstrated to have high adherence. In the latter case, care was assumed to be primarily differentiated according to viral load level. The maximum intervention cost required to be cost effective was calculated based on a cost effectiveness threshold of 500perDALYaverted.FindingsIntheabsenceofviralloadmonitoring,anadherencemonitoringbasedinterventionwhichresultsinadurable6500 per DALY averted. Findings In the absence of viral load monitoring, an adherence monitoring-based intervention which results in a durable 6% increase in the proportion of ART experienced people with viral load <1000 cps/mL was cost effective if it cost up to 50 per person-year on ART, mainly driven by the cost savings of differentiation of care. In the presence of viral load monitoring availability, an intervention with a similar effect on viral load suppression was cost-effective when costing 2323-32 per year, depending on whether the adherence intervention is used to reduce the level of need for viral load measurement. Conclusion The cost thresholds identified suggest that there is clear scope for adherence monitoringbased interventions to provide net population health gain, with potential cost-effective use in situations where viral load monitoring is or is not available. Our results guide the implementation of future adherence monitoring interventions found in randomized trials to have health benefit

    Limits from the FUNK experiment on the mixing strength of hidden-photon dark matter in the visible and near-ultraviolet wavelength range

    Get PDF
    We present results from the FUNK experiment in the search for hidden-photon dark matter. Near the surface of a mirror, hidden photons may be converted into ordinary photons. These photons are emitted perpendicularly to the surface and have an energy equal to the mass of the dark matter hidden photon. Our experimental setup consists of a large, spherical mirror with an area of more than 14  m2, which concentrates the emitted photons into its central point. Using a detector sensitive to visible and near-UV photons, we can exclude a kinetic-mixing coupling of stronger than χ≈10−12 in the mass range of 2.5 to 7 eV, assuming hidden photons comprise all of the dark matter. The experimental setup and analysis used to obtain this limit are discussed in detai

    A plot twist: the continuing story of VCSELs at AOC

    Get PDF
    ABSTRACT During a year of substantial consolidation in the VCSEL industry, Honeywell sold their VCSEL Optical Products Division, which has now officially changed its name to Advanced Optical Components (AOC). Both manufacture and applied research continue, however. Some of the developments of the past year are discussed in this paper. They include advances in the understanding of VCSEL degradation physics, substantial improvements in long-wavelength VCSEL performance, and continuing progress in manufacturing technology. In addition, higher speed serial communications products, at 10 gigabits and particularly at 4 gigabits per second, have shown faster than predicted growth. We place these technologies and AOC&apos;s approach to them in a market perspective, along with other emerging applications
    corecore