166 research outputs found

    Clinical value of whole-body magnetic resonance imaging in health screening of general adult population.

    Get PDF
    BACKGROUND: Whole-body magnetic resonance imaging (WB-MRI) and angiography (WB-MRA) has become increasingly popular in population-based research. We evaluated retrospectively the frequency of potentially relevant incidental findings throughout the body. MATERIALS AND METHODS: 22 highly health-conscious managers (18 men, mean age 47+/-9 years) underwent WB-MRI and WB-MRA between March 2012 and September 2013 on a Discovery MR750w wide bore 3 Tesla device (GE Healthcare) using T1 weighted, short tau inversion recovery (STIR) and diffusion weighted imaging (DWI) acquisitions according to a standardized protocol. RESULTS: A suspicious (pararectal) malignancy was detected in one patient which was confirmed by an endorectal sonography. Incidental findings were described in 20 subjects, including hydrocele (11 patients), benign bony lesion (7 patients) and non-specific lymph nodes (5 patients). Further investigations were recommended in 68% (ultrasound: 36%, computed tomography: 28%, mammography: 9%, additional MRI: 9%). WB-MRA were negative in 16 subjects. Vascular normal variations were reported in 23%, and a 40% left proximal common carotid artery stenosis were described in one subject. CONCLUSIONS: WB-MRI and MRA lead to the detection of clinically relevant diseases and unexpected findings in a cohort of healthy adults that require further imaging or surveillance in 68%. WB-MR imaging may play a paramount role in health screening, especially in the future generation of (epi)genetic based screening of malignant and atherosclerotic disorders. Our study is the first which involved a highly selected patient group using a high field 3-T wide bore magnet system with T1, STIR, MRA and whole-body DWI acquisitions as well

    Acute severe thrombocytopenia following non-ionic low-osmolarity intravenous contrast medium injection

    Get PDF
    Intravenous contrast medium (ICM) rarely induces anaphylactic reactions, including urticaria, hypotension and respiratory failure. Even the most modern ICM may cause such adverse events. Thrombocytopenia has been reported as an extreme rare consequence of ICM. Here we report on a case of a 72-year-old male patient with a self-limiting severe acute thrombocytopenia following administration of intravenous non-ionic low-osmolarity contrast medium. No such low platelet count has ever been reported. We also present a review of the literature. Copyright © 2012 The Korean Society of Radiology

    Femoral artery ultrasound examination: a new role in predicting cardiovascular risk

    Get PDF
    We compared intima-media thickness (IMT) and the prevalence of plaques in the common carotid artery (CCA) and common femoral artery (CFA) in apparently healthy participants. This multicenter study included 322 participants (59.9% female; age 20-78 years, mean 52.1 ± 15.3 years) who underwent Echo-color Doppler examination of the CCA and CFA bilaterally. Prevalence and composition of plaque were recorded. A significant ( P < .01) difference between mean CCA-IMT and mean CFA-IMT was detected (0.70 vs 0.73 mm). Plaque prevalence was significantly higher in the CFA compared to the CCA (40.7% vs 30.4%). Atherosclerotic plaques were found in both CFA and CCA in 46% of the cases, solely in CFA in 38%, and in CCA alone in 17%. The observed difference in plaque prevalence was even greater when only fibrolipid isolated plaques were considered (CFA 39.4% vs CCA 22.1%). In a healthy general population, atherosclerotic plaques were present in the CFA but not in the CCA in over one-third of the cases. Further studies must confirm whether ultrasonography of the CFA might be introduced in the screening protocols for cardiovascular risk assessment

    Associations between birth size and later height from infancy through adulthood : an individual based pooled analysis of 28 twin cohorts participating in the CODATwins project

    Get PDF
    Background: There is evidence that birth size is positively associated with height in later life, but it remains unclear whether this is explained by genetic factors or the intrauterine environment. Aim: To analyze the associations of birth weight, length and ponderal index with height from infancy through adulthood within mono- and dizygotic twin pairs, which provides insights into the role of genetic and environmental individual-specific factors. Methods: This study is based on the data from 28 twin cohorts in 17 countries. The pooled data included 41,852 complete twin pairs (55% monozygotic and 45% same-sex dizygotic) with information on birth weight and a total of 112,409 paired height measurements at ages ranging from 1 to 69 years. Birth length was available for 19,881 complete twin pairs, with a total of 72,692 paired height measurements. The association between birth size and later height was analyzed at both the individual and within-pair level by linear regression analyses. Results: Within twin pairs, regression coefficients showed that a 1-kg increase in birth weight and a 1-cm increase in birth length were associated with 1.14-4.25 cm and 0.18-0.90 cm taller height, respectively. The magnitude of the associations was generally greater within dizygotic than within monozygotic twin pairs, and this difference between zygosities was more pronounced for birth length. Conclusion: Both genetic and individual-specific environmental factors play a role in the association between birth size and later height from infancy to adulthood, with a larger role for genetics in the association with birth length than with birth weight

    Genetic and environmental influence on thyroid gland volume and thickness of thyroid isthmus: a twin study

    Get PDF
    ABSTRACT Objectives: Decreased thyroid volume has been related to increased prevalence of thyroid cancer. Subjects and methods: One hundred and fourteen Hungarian adult twin pairs (69 monozygotic, 45 dizygotic) with or without known thyroid disorders underwent thyroid ultrasound. Thickness of the thyroid isthmus was measured at the thickest portion of the gland in the midline using electronic calipers at the time of scanning. Volume of the thyroid lobe was computed according to the following formula: thyroid height*width*depth*correction factor (0.63). Results: Age-, sex-, body mass indexand smoking-adjusted heritability of the thickness of thyroid isthmus was 50% (95% confidence interval [CI], 35 to 66%). Neither left nor right thyroid volume showed additive genetic effects, but shared environments were 68% (95% CI, 48 to 80%) and 79% (95% CI, 72 to 87%), respectively. Magnitudes of monozygotic and dizygotic co-twin correlations were not substantially impacted by the correction of covariates of body mass index and smoking. Unshared environmental effects showed a moderate influence on dependent parameters (24-50%). Conclusions: Our analysis support that familial factors are important for thyroid measures in a general twin population. A larger sample size is needed to show whether this is because of common environmental (e.g. intrauterine effects, regional nutrition habits, iodine supply) or genetic effects. Arch Endocrinol Metab. 2015;59(6):487-9

    Genetic and environmental influence on thyroid gland volume and thickness of thyroid isthmus: a twin study

    Get PDF
    ABSTRACT Objectives: Decreased thyroid volume has been related to increased prevalence of thyroid cancer. Subjects and methods: One hundred and fourteen Hungarian adult twin pairs (69 monozygotic, 45 dizygotic) with or without known thyroid disorders underwent thyroid ultrasound. Thickness of the thyroid isthmus was measured at the thickest portion of the gland in the midline using electronic calipers at the time of scanning. Volume of the thyroid lobe was computed according to the following formula: thyroid height*width*depth*correction factor (0.63). Results: Age-, sex-, body mass indexand smoking-adjusted heritability of the thickness of thyroid isthmus was 50% (95% confidence interval [CI], 35 to 66%). Neither left nor right thyroid volume showed additive genetic effects, but shared environments were 68% (95% CI, 48 to 80%) and 79% (95% CI, 72 to 87%), respectively. Magnitudes of monozygotic and dizygotic co-twin correlations were not substantially impacted by the correction of covariates of body mass index and smoking. Unshared environmental effects showed a moderate influence on dependent parameters (24-50%). Conclusions: Our analysis support that familial factors are important for thyroid measures in a general twin population. A larger sample size is needed to show whether this is because of common environmental (e.g. intrauterine effects, regional nutrition habits, iodine supply) or genetic effects

    Laterality of deep white matter hyperintensities correlates with basilar artery bending and vertebral artery dominance

    Get PDF
    Aim To investigate whether vertebrobasilar geometry contributes to the presence, severity, and laterality of white matter hyperintensities (WMH). Methods We retrospectively reviewed 290 cerebral scans of patients who underwent time-of-flight and fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) between 2017 and 2018. WMH were counted, localized, and grouped according to laterality on the FLAIR sequence. A 3D mesh of the posterior circulation was reconstructed (with ITK SNAP software) and the morphology of the vertebrobasilar system analyzed with an in-house software written in Python. Results Patients were assigned into a group with WMH (n=204) and a group without WMH (n=86). The severity of WMH burden was mainly affected by age and hypertension, while the localization of the WMH (or laterality) was mainly affected by the vertebrobasilar system morphology. Basilar artery morphology only affected the parietooccipital region significantly if both posterior communicating arteries were hypoplastic or absent. The dominant vertebral artery and basilar artery curve had an opposite directional relationship. Conclusions An unequal vertebral artery flow is an important hemodynamic contributor to basilar bending. Increased basilar artery curvature and increased infratentorial WMH burden may signal inadequate blood flow and predict cerebrovascular events

    Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer

    Get PDF
    BACKGROUND: Electronic noses are composites of nanosensor arrays. Numerous studies showed their potential to detect lung cancer from breath samples by analysing exhaled volatile compound pattern ("breathprint"). Expiratory flow rate, breath hold and inclusion of anatomic dead space may influence the exhaled levels of some volatile compounds; however it has not been fully addressed how these factors affect electronic nose data. Therefore, the aim of the study was to investigate these effects. METHODS: 37 healthy subjects (44 +/- 14 years) and 27 patients with lung cancer (60 +/- 10 years) participated in the study. After deep inhalation through a volatile organic compound filter, subjects exhaled at two different flow rates (50 ml/sec and 75 ml/sec) into Teflon-coated bags. The effect of breath hold was analysed after 10 seconds of deep inhalation. We also studied the effect of anatomic dead space by excluding this fraction and comparing alveolar air to mixed (alveolar + anatomic dead space) air samples. Exhaled air samples were processed with Cyranose 320 electronic nose. RESULTS: Expiratory flow rate, breath hold and the inclusion of anatomic dead space significantly altered "breathprints" in healthy individuals (p 0.05). These factors also influenced the discrimination ability of the electronic nose to detect lung cancer significantly. CONCLUSIONS: We have shown that expiratory flow, breath hold and dead space influence exhaled volatile compound pattern assessed with electronic nose. These findings suggest critical methodological recommendations to standardise sample collections for electronic nose measurements
    corecore